4
AT24C128/256
0670T–SEEPR–3/07
Table 2. Pin Capacitance
(1)
Note: 1. This parameter is characterized and is not 100% tested.
Table 3. DC Characteristics
(1)
Notes: 1. V
IL
min and V
IH
max are reference only and are not tested.
2. The AT24C128/256 bearing the process letter “B” on the package (the mark is located in the lower right corner on the top-
side of the package) are approved for operation in the extended temperature range.
Applicable over recommended operating range from T
A
= 25° C, f = 1.0 MHz, V
CC
= +1.8V.
Symbol Test Condition Max Units Conditions
C
I/O
Input/Output Capacitance (SDA) 8 pF V
I/O
= 0V
C
IN
Input Capacitance (A
0
, A
1
, SCL) 6 pF V
IN
= 0V
Applicable over recommended operating range from: T
AI
= 40° C to +85° C, V
CC
= +1.8V to +5.5V; T
AE
= 40° C to
+125° C
(2)
, V
CC
= +2.7V to +5.5V(unless otherwise noted).
Symbol Parameter Test Condition Min Typ Max Units
V
CC1
Supply Voltage 1.8 3.6 V
V
CC2
Supply Voltage 2.5 5.5 V
V
CC3
Supply Voltage 4.5 5.5 V
I
CC1
Supply Current V
CC
= 5.0V READ at 400 kHz 1.0 2.0 mA
I
CC2
Supply Current V
CC
= 5.0V WRITE at 400 kHz 2.0 3.0 mA
I
SB1
Standby Current
(1.8V option)
V
CC
= 1.8V
V
IN
= V
CC
or V
SS
0.2 µA
V
CC
= 3.6V 2.0
I
SB2
Standby Current
(2.5V option)
V
CC
= 2.5V
V
IN
= V
CC
or V
SS
0.5 µA
V
CC
= 5.5V 6.0
I
SB3
Standby Current
(5.0V option)
V
CC
= 4.5 - 5.5V V
IN
= V
CC
or V
SS
6.0 µA
I
LI
Input Leakage Current V
IN
= V
CC
or
V
SS
0.10 3.0 µA
I
LO
Output Leakage
Current
V
OUT
= V
CC
or
V
SS
0.05 3.0 µA
V
IL
Input Low Level
(1)
–0.6 V
CC
x 0.3 V
V
IH
Input High Level
(1)
V
CC
x 0.7 V
CC
+ 0.5 V
V
OL2
Output Low Level V
CC
= 3.0V I
OL
= 2.1 mA 0.4 V
V
OL1
Output Low Level V
CC
= 1.8V I
OL
= 0.15 mA 0.2 V
5
AT24C128/256
0670T–SEEPR–3/07
Table 4. AC Characteristics – Industrial Temperatures
Notes: 1. This parameter is characterized and is not 100% tested.
2. AC measurement conditions:
R
L
(connects to V
CC
): 1.3 kΩ (2.5V, 5V), 10 kΩ (1.8V)
Input pulse voltages: 0.3 V
CC
to 0.7 V
CC
Input rise and fall times: 50 ns
Input and output timing reference voltages: 0.5 V
CC
3. The Write Cycle Time of 5 ms only applies to the AT24C128/256 devices bearing the process letter “B” on the package (the
mark is located in the lower right corner on the top side of the package).
4. The AT24C128/256 bearing the process letter “B” in the package (the mark is located in the lower right corner on the top
side of the package), guarantees 1 million write cycle endurance (1.8 – 3.6V).
Applicable over recommended operating range from T
AI
= 40° C to +85° C, V
CC
= +1.8V to +5.5V, CL = 100 pF (unless oth-
erwise noted). Test conditions are listed in Note 2.
Symbol Parameter
1.8-volt 2.5-volt 5.0-volt
UnitsMin Max Min Max Min Max
f
SCL
Clock Frequency, SCL 100 400 1000 kHz
t
LOW
Clock Pulse Width Low 4.7 1.3 0.4 µs
t
HIGH
Clock Pulse Width High 4.0 0.6 0.4 µs
t
AA
Clock Low to Data Out Valid 0.1 4.5 0.05 0.9 0.05 0.55 µs
t
BUF
Time the bus must be free before a
new transmission can start
(1)
4.7 1.3 0.5 µs
t
HD.STA
Start Hold Time 4.0 0.6 0.25 µs
t
SU.STA
Start Set-up Time 4.7 0.6 0.25 µs
t
HD.DAT
Data In Hold Time 0 0 0 µs
t
SU.DAT
Data In Set-up Time 200 100 100 ns
t
R
Inputs Rise Time
(1)
1.0 0.3 0.3 µs
t
F
Inputs Fall Time
(1)
300 300 100 ns
t
SU.STO
Stop Set-up Time 4.7 0.6 0.25 µs
t
DH
Data Out Hold Time 100 50 50 ns
t
WR
Write Cycle Time 20 or 5
(3)
10 or 5
(3)
10 or 5
(3)
ms
Endurance
(1)
25°C, Page Mode 100k or 1,000,000
(4)
Write
Cycles
6
AT24C128/256
0670T–SEEPR–3/07
Table 5. AC Characteristics
(5)
– Extended Temperatures
Notes: 1. This parameter is characterized and is not 100% tested.
2. AC measurement conditions:
R
L
(connects to V
CC
): 1.3 kΩ (2.5V, 5V), 10 kΩ (1.8V)
Input pulse voltages: 0.3 V
CC
to 0.7 V
CC
Input rise and fall times: 50 ns
Input and output timing reference voltages: 0.5 V
CC
3. The Write Cycle Time of 5 ms only applies to the AT24C128/256 devices bearing the process letter “B” on the package (the
mark is located in the lower right corner on the top side of the package).
4. The AT24C128/256 bearing the process letter “B” in the package (the mark is located in the lower right corner on the top
side of the package), guarantees 1 million write cycle endurance (1.8 – 3.6V).
5. The AT24C128/256 bearing the process letter “B” on the package (the mark is located in the lower right corner on the top-
side of the package) are approved for operation in the extended temperature range.
Applicable over recommended operating range from T
AE
= 40° C to +125° C, V
CC
= +2.7V to +5.5V, CL = 100 pF (unless
otherwise noted). Test conditions are listed in Note 2.
Symbol Parameter
2.7-volt 5.0-volt
UnitsMin Max Min Max
f
SCL
Clock Frequency, SCL 400 1000 kHz
t
LOW
Clock Pulse Width Low 1.3 0.4 µs
t
HIGH
Clock Pulse Width High 0.6 0.4 µs
t
AA
Clock Low to Data Out Valid 0.05 0.9 0.05 0.55 µs
t
BUF
Time the bus must be free before a new
transmission can start
(1)
1.3 0.5 µs
t
HD.STA
Start Hold Time 0.6 0.25 µs
t
SU.STA
Start Set-up Time 0.6 0.25 µs
t
HD.DAT
Data In Hold Time 0 0 µs
t
SU.DAT
Data In Set-up Time 100 100 ns
t
R
Inputs Rise Time
(1)
0.3 0.3 µs
t
F
Inputs Fall Time
(1)
300 100 ns
t
SU.STO
Stop Set-up Time 0.6 0.25 µs
t
DH
Data Out Hold Time 50 50 ns
t
WR
Write Cycle Time 10 or 5
(3)
10 or 5
(3)
ms
Endurance
(1)
25°C, Page Mode 100k or 1,000,000
(4)
Write
Cycles

AT24C128N-10SU-2.7

Mfr. #:
Manufacturer:
Description:
IC EEPROM 128K I2C 1MHZ 8SOIC
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: