Air performance measured according to: ISO 5801.
Installation category A, without contact protection.
Noise: Total sound power level L
W
A ISO 103002
measured on a hemisphere with a radius of 2 m.
Sound pressure level L
p
A measured at 1 m distance from
fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
– Possible special versions:
(See chapter DC fans - specials)
- Speed signal
- Go / NoGo alarm
- Alarm with speed limit
- External temperature sensor
- Internal temperature sensor
- PWM control input
- Analog control input
- Moisture protection
Max. 170 m
3
/h
Type m
3
/h cfm VDC VDC dB(A) Bel(A) / Watts rpm
-1
°C Hours Hours
4412 FGL 94 55 12 7...14 26 3.9 1.3 1 600 -20...+75 80 000 / 32 500 135 000 ¿
4412 FGML 114 67 12 7...12.6 32 4.3 2.0 1 950 -20...+75 75 000 / 30 000 127 500 ¡
4412 FML 114 67 12 7...12.6 32 4.3 2.0 1 950 -20...+75 75 000 / 30 000 127 500 ¡
4412 FGM 140 82 12 7...12.6 38 4.8 3.2 2 400 -20...+75 70 000 / 27 500 117 500 ¬
4412 FM 140 82 12 7...12.6 38 4.8 3.2 2 400 -20...+75 70 000 / 27 500 117 500 ¬
4412 FG 170 100 12 8...12.6 43 5.3 5.3 2 900 -20...+60 60 000 / 37 500 102 500 √
4412 F 170 100 12 8...12.6 43 5.3 5.3 2 900 -20...+60 60 000 / 37 500 102 500 √
4414 FL 94 55 24 18...28 26 3.9 1.2 1 600 -20...+75 80 000 / 32 500 135 000 ¿
4414 FM 140 82 24 12...28 38 4.8 3.1 2 400 -20...+75 70 000 / 27 500 117 500 ¬
4414 FG 170 100 24 12...28 43 5.3 5.0 2 900 -20...+60 60 000 / 37 500 102 500 √
4414 F 170 100 24 12...28 43 5.3 5.0 2 900 -20...+60 60 000 / 37 500 102 500 √
4418 FG 170 100 48 28...53 43 5.3 5.4 2 900 -20...+60 60 000 / 37 500 102 500 √
4418 F 170 100 48 28...53 43 5.3 5.4 2 900 -20...+60 60 000 / 37 500 102 500 √
Subject to change
Nominal voltage
Air flow
Air flow
Voltage range
Sound pressure level
Sound power level
Sintec sleeve bearings
Ball bearings
Power consumption
Nominal speed
Temperature range
Service life L
10
(40 °C)
ebm-papst standard
Service life L
10
(T
max
)
ebm-papst standard
Life expectancy L
10IPC
(40 °C) see page 17
Curve
– Material: Housing: GRP
1)
(PBT)
Impeller: GRP
1)
(PA)
– Direction of air flow: Exhaust over struts
– Direction of rotation: Counterclockwise,
looking towards rotor
– Connection: Via single wires AWG 24,
TR 64
– Highlights: Ball bearings and sleeve
bearings available
– Weight: 175 g
1) Fiberglass-reinforced plastic
Available as an option:
Fan housing with molded-in
spacers
Tin-plated
53
2016-01
2 1 1 7 7 3 7 - 8 1
2 1 2 1 7 3 7 - 8 1
1 8 4 3 5 7 4 - 1 1
2 1 4 3 7 2 6 - 9 1
2 1 4 3 7 3 7 - 8 1
Information
DC axial fansDC fans - specials
AC axial fans
Accessories
Representatives
DC centrifugal fansAC centrifugal fans
Finger guards
from p. 242
ACmaxx / EC fans
DC axial fans
119 x 25 mm
Series 4400 F
Nominal data