AQJ212V

–1–
ASCTB216E 201510-T
ORDERING INFORMATION
TYPES
1. AQ-J Solid State Relays
Standard Packing; carton: 10 pcs., case: 200 pcs.
Note: Random type also available. Please inquire.
Load current 10 to 25A
Small Tab Terminal SSR
AQ-J RELAYS
Type Load current Load voltage Input voltage Part No.
Zero-cross*
10A
75V to 264V AC
4 to 6V DC AQJ112V
10 to 18V DC AQJ119V
18 to 28V DC AQJ116V
15A
4 to 6V DC AQJ212V
10 to 18V DC AQJ219V
18 to 28V DC AQJ216V
25A
4 to 6V DC AQJ412V
10 to 18V DC AQJ419V
18 to 28V DC AQJ416V
UL (60950-1) reinforced
insulation compliant
FEATURES
1. Compact Size
W 28 × L 38 × H 30 mm
W 1.102 × L 1.496 × H 1.181 inch
2. Built-in varistor
3. Reverse input connection
prevention function
4. Labor Saving (tab terminal)
5. Heat sink combined types ready to
mount on DIN rail added (Radiating
grease and screws assembly process
not needed)
6. Output arrangement 1a and 1a × 2
available in the heat sink combined
type
Note: * International standards are acquired for
AQ-J SSR stand-alone, not applied to heat
sink combined type.
TYPICAL APPLICATIONS
1. Kitchen appliances
2. Vending machine
3. Injection molding machine
4. Packing machine
5. Amusement machine
Slim heat sink combined type
RoHS compliant
Output type
1: 10A, 75V to 264V AC
2: 15A, 75V to 264V AC
4: 25A, 75V to 264V AC
AQJ
Terminal, Type
1: Tab terminal, Zero-cross
2: Tab terminal, Random*
Input voltage
2: 4 to 6 V DC
6: 18 to 28 V DC
9: 10 to 18 V DC
Functions
V: Built-in varistor
Slim heat sink combined type
None:
Y:
W:
Without a heat sink
1a type
1a × 2 type
Note: * Random type is available by custom order.
AQ-J
–2–
ASCTB216E 201510-T
2. AQ-J Slim Heat Sink Combined Type
Standard Packing; no carton, case: 10 pcs.
Note: * Random type also available. Please inquire.
3. Accessories
RATING
1. Ratings (Test sample: AQ-J stand-alone, Measurement condition: at 20°C 68°F, input ripple: 1% or less)
1) Input side
Note: Refer to REFERENCE DATA “3. Input current vs. input voltage characteristics”.
2) Output side
Notes: *1. Refer to REFERENCE DATA “1. Load current vs. ambient temperature”.
*2. When the load current is less than the rated minimum load current, please refer to “Cautions for Use”.
2. Ratings (Test sample: AQ-J slim heat sink combined type, Measurement condition: at 20°C 68°F, input ripple: 1 % or less)
1) Input side
Note: Refer to REFERENCE DATA “3. Input current vs. input voltage characteristics”.
Output configuration Type Load current Load voltage Input voltage Part No.
1a
Zero-cross*
10A
75V to 264V AC
4 to 6V DC AQJ112VY
10 to 18V DC AQJ119VY
18 to 28V DC AQJ116VY
20A
4 to 6V DC AQJ412VY
10 to 18V DC AQJ419VY
18 to 28V DC AQJ416VY
1a × 2
10A
(per 1a)
4 to 6V DC AQJ112VW
10 to 18V DC AQJ119VW
18 to 28V DC AQJ116VW
15A
(per 1a)
4 to 6V DC AQJ412VW
10 to 18V DC AQJ419VW
18 to 28V DC AQJ416VW
Type Part No. Packaged quantity
Slim heat sink (28mm wide) (Mountable on a DIN rail) AQP-HS-SJ10A No carton, 10 in a case
Slim heat sink (45mm wide) (Mountable on a DIN rail) AQP-HS-SJ20A No carton, 8 in a case
Standard heat sink (10A and 15A) AQP-HS-J10A 5 in a carton, 20 in a case
Standard heat sink (25A only) AQP-HS-J25A No carton, 5 in a case
DIN rail mounting plate AQP-DPJ No carton, 50 in a case
Mounting rail AT8-DLA1 1 in a carton, 100 in a case
Fastening plate AT8-DLE 1 in a carton, 200 in a case
Part No.
Item
AQJ112V
AQJ212V
AQJ412V
AQJ119V
AQJ219V
AQJ419V
AQJ116V
AQJ216V
AQJ416V
Rated voltage 5V DC 12V DC 24V DC
Input voltage 4 to 6V DC 10 to 18V DC 18 to 28V DC
Input impedance Approx. 0.26kΩ Approx. 0.8kΩ Approx. 1.6kΩ
Drop-out voltage Min. 1V DC
Part No.
Item
AQJ112V
AQJ119V
AQJ116V
AQJ212V
AQJ219V
AQJ216V
AQJ412V
AQJ419V
AQJ416V
Max. load current*
1
10A 15A 25A
Load voltage 75 to 264V AC
Frequency 45Hz to 65Hz
Non-repetitive surge current 100A 150A 250A
“OFF-state” leakage current Max. 5mA
“ON-state” voltage drop Max. 1.6V
Min. load current*
2
50mA
Part No.
Item
AQJ112V(Y·W)
AQJ412V(Y·W)
AQJ119V(Y·W)
AQJ419V(Y·W)
AQJ116V(Y·W)
AQJ416V(Y·W)
Rated voltage 5V DC 12V DC 24V DC
Input voltage 4 to 6V DC 10 to 18V DC 18 to 28V DC
Input impedance Approx. 0.26kΩ Approx. 0.8kΩ Approx. 1.6kΩ
Drop-out voltage Min. 1V DC
AQ-J
–3–
ASCTB216E 201510-T
2) Output side
Notes: *1. Refer to REFERENCE DATA “3. Input current vs. input voltage characteristics”.
*2. Refer to REFERENCE DATA “1. Load current vs. ambient temperature”.
*3. When the load current is less than the rated minimum load current, please refer to “Cautions for Use”.
3. Characteristics (Measurement condition: at 20°C 68°F, input ripple: 1% or less)
REFERENCE DATA
(1) AQ-J Solid State Relays
1. Load current vs. ambient temperature Use load current within range specified in the figure below
Part No.
Item
AQJ112VY
AQJ119VY
AQJ116VY
AQJ412VY
AQJ419VY
AQJ416VY
AQJ112VW
AQJ119VW
AQJ116VW
AQJ412VW
AQJ419VW
AQJ416VW
Output arrangement 1a 1a × 2
Max. load current*
1
10A 20A 10A 15A
Load voltage 75 to 264V AC
Frequency 45Hz to 65Hz
Non-repetitive surge current*
2
100A 250A 100A 250A
“OFF-state” leakage current Max. 5mA
“ON-state” voltage drop Max. 1.6V
Min. load current*
3
50mA
Item Characteristics Remarks
Operate time Max. 1/2 cycle of voltage sine wave + 1ms
Release time Max. 1/2 cycle of voltage sine wave + 1ms
Insulation resistance Min. 100MΩ between input, output and case at 500 V DC
Breakdown voltage
3,000 Vrms between input and output
for 1min.
2,500 Vrms between input, output and case
Vibration resistance
SSR stand-alone: 10 to 55Hz, double amplitude of 1.5mm
Slim heat sink combined type: 10 to 55Hz, double amplitude of 0.75mm
X, Y, Z axes
Shock resistance
SSR stand-alone: Min. 980m/s
2
Slim heat sink combined type: Min. 197m/s
2
X, Y, Z axes
Ambient temperature –30 to +80°C –22 to +176°F Non-condensing at low temperatures
Storage temperature –30 to +100°C –22 to +212°F Non-condensing at low temperatures
Operational method Zero-cross (Turn ON and Turn OFF)
Tested condition:
1) If attached to a heat sink, use a heat
conductive compound (Ex. Momentive
Performance Materials Inc. YG6111 or
TSK5303) of similar coating to improve cooling
2) Without external heat sink
If the mounting surface is not metallic and a
heat sink is not used, expose the bottom
surface and plate surface to improve heat
dissipation.
3) The current value is per 1a.
(1) 10 A type (when using heat sink or iron
plate)
(2)-1. 15 A type (when using iron plate)
(A) slim heat sink AQP-HS-SJ20A
(B) slim heat sink AQP-HS-SJ10A
(C) standard heat sink AQP-HS-J10A
(D) DIN rail mounting plate AQP-DPJ
(E) standard heat sink AQP-HS-J25A
100806040200
2
4
6
8
12
10
0
When a single unit is mounted on an (A) slim heat sink
When a single unit is mounted
on an (B) slim heat sink
When two units are mounted
on an (A) slim heat sink
When a single unit is mounted
on an (C) standard heat sink
When two units are mounted
on an (B) slim heat sink
When using 100×100×t1.6 mm iron plate
When using as stand-alone
When using an (D) DIN rail mounting plate
Ambient temperature, °C
Load current, A
6
12
9
3
18
15
0
0-20 20 40 60 80
Ambient temperature, °C
Load current, A
When using 200 × 200 × t2 mm iron plate
When using
100 × 100 × t1.6 mm
iron plate
When using
150 × 150 × t1.6 mm
iron plate
(2)-2. 15 A type (when using a heat sink) (3)-1. 25 A type (when using iron plate) (3)-2. 25 A type (when using a heat sink)
100806040200
5
10
15
20
0
When a single unit
is mounted on an
(A) slim heat sink
When a single unit is mounted
on an (C) standard heat sink
When a single unit is mounted
on an (B) slim heat sink
When two units are mounted
on an (B) slim heat sink
When two units are mounted
on an (A) slim heat sink
When using as stand-alone
When using an (D) DIN rail mounting plate
Ambient temperature, °C
Load current, A
0-20 20 40 60 80
5
10
15
20
25
30
0
Ambient temperature, °C
Load current, A
When using 300 × 300 × t2 mm iron plate
When using 150 × 150 × t1.6 mm
iron plate
When using 100 × 100 × t1.6 mm
iron plate
When using 250 × 250 × t2 mm
iron plate
When using
200 × 200 × t2 mm
iron plate
100806040200
5
10
15
20
30
25
0
When two units
are mounted on an
(B) slim heat sink
When a single
unit is mounted on an
(B) slim heat sink
When two units are
mounted on an (A)
slim heat sink
When a single unit is mounted
on an (C) standard heat sink
When a single unit is
mounted on an (A)
slim heat sink
When using as stand-alone
When using an (D) DIN rail mounting plate
When a single unit is
mounted on an (E)
standard heat sink
Ambient temperature, °C
Load current, A

AQJ212V

Mfr. #:
Manufacturer:
Panasonic Industrial Devices
Description:
Solid State Relays - Industrial Mount 15A 4 TO 6 VDC
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: