HEP-185-12A

185W Single Output Switching Power Supply
HEP-185 series
File Name:HEP-185-SPEC 2018-01-15
Features Applications
Model Encoding
Function mode option
Output voltage
Output wattage
Series name
HEP -- 185 12 A
{
through internal potentiometer.
A : Standard model, IP65, Vo and o level can be adjustedI
5
Description
HEP-185 is a 185W industrial AC/DC power supply featuring the outstanding capability to operate under
highly humid, dusty, oily, and high-vibration harsh environment. The entire series is housed with the
aluminum case and fully potted with heat-conducted silicone. Thanks to state-of-the-art design, the
working efficiency is up to 94%, enabling HEP-185 perfectly work between -55 and +70 under free
℃℃
air convection.
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
High efficiency up to 94%
Fanless design, cooling by free air convection
-55~+70 wide operating range
Aluminum case and filling with heat-conducted silicone
IP65 design, optional IP68 rated model available
Meet 6KV surge immunity level
Withstand 10G vibration test
Protections: Short circuit / Overload / Over voltage
/ Over temperature
Operating altitude up to 5000 meters (Note.9)
6 years warranty
Outdoor telecommunication equipment
Outdoor electronic signage and billboard
Petroleum plant or mine shaft facility
Blank : Optional model, IP68, with fixed Vo and Io level.
IP65 IP68
(optional)
SPECIFICATION
185W Single Output Switching Power Supply
HEP-185 series
File Name:HEP-185-SPEC 2018-01-15
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE Note.5
CURRENT ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME Note.7
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT
(Typ.)
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
OVERLOAD
OVER VOLTAGE
OVER TEMPERATURE
Can be adjusted by internal potentiometer for A type only
1000ms,50ms/115VAC 500ms,50ms/230VAC at full load
16ms at full load 230VAC /115VAC
90 ~ 305VAC 127 ~ 431VDC
47 ~ 63Hz
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load
1.8A / 115VAC 0.8A / 230VAC 0.7A / 277VAC
2.1A / 115VAC 1A / 230VAC 0.8A / 277VAC
12V
15V ~ 54V
<0.75mA / 277VAC
105 ~ 125%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level (surge 6KV), criteria A, EAC TP TC 020
-55 ~ +70 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-60 ~ +80 , 10 ~ 95% RH non-condensing
±℃ 0.03%/ (0 ~ 60 )
20 ~ 500Hz, 10G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL60950-1 EAC TP TC 004
,, IP65 (or IP68 for HEP-185 Blank type) approved ; design refer to TUV EN60950-1
164.1K hrs min. MIL-HDBK-217F (25 )
228*68*38.8mm (L*W*H)
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
Shut down o/p voltage, recovers automatically after temperature goes down
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
SHORT CIRCUIT
Constant current limiting, recovers automatically after fault condition is removed
14 ~ 17V 18 ~ 21V 28 ~ 34V 41 ~ 46V 54 ~ 63V 59 ~ 65V
91.5% 92% 93.5% 93.5% 94% 94%
±2.5% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0%
6.5 ~ 13A 5.75 ~ 11.5A 3.9 ~ 7.8A 2.6 ~ 5.2A 1.95 ~ 3.9A 1.72 ~ 3.45A
±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±2.0% ±1.5% ±0.5% ±0.5% ±0.5% ±0.5%
12V 15V 24V 36V 48V 54V
HEP-185-12 HEP-185-15 HEP-185-24 HEP-185-36 HEP-185-48 HEP-185-54
13A 11.5A 7.8A 5.2A 3.9A 3.45A
156W 172W 187.2W 187.2W 187.2W 186.3W
150mVp-p 150mVp-p 150mVp-p 200mVp-p 200mVp-p 200mVp-p
10.8 ~ 13.5V 13.5 ~ 17V 22 ~ 27V 33 ~ 40V 43 ~ 53V 49 ~ 58V
EMC IMMUNITY
EMC EMISSION
COLD START 65A at 230VAC
PACKING
1.15Kg; 12pcs/14.8Kg/0.8CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. A type only.
6. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
8. The power supply is considered as a component that
will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
9. The water protection level test for the IP68 rating is performed 1000mm below the surface of the water for 1 month.
10. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude℃℃
higher than 2000m(6500ft).
SAFETY STANDARDS Note.6,9
Derating Curve Static Characteristics
90 100 125 135 145 155 165 175 180 200 230 305
100
90
80
70
60
50
40
LOAD (%)
LOAD (%)
-55 -25 -10 0 15 30 50 60 70
20
40
60
80
100
(HORIZONTAL)
AMBIENT TEMPERATURE ( ) INPUT VOLTAGE (V) 60Hz
Fosc : 100KHz
DETECTION
PWM
CIRCUIT
EMI FILTER
RECTIFIERS
POWER
SWITCHING
FILTER
&
RECTIFIERS
+V
-V
I/P
FG
CONTROL
O.V.P.
&
O.L.P.
PFC
CIRCUIT
PFC
CONTROL
O.L.P.
O.T.P.
185W Single Output Switching Power Supply
HEP-185 series
File Name:HEP-185-SPEC 2018-01-15
Block Diagram

HEP-185-12A

Mfr. #:
Manufacturer:
MEAN WELL
Description:
Switching Power Supplies 156W 12V 13A IP65 W/PFC
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet