IS31FL3190-UTLS2-TR

IS31FL3190
Integrated Silicon Solution, Inc. www.issi.com 7
Rev.0A, 10/20/2015
Figure 4 Writing to IS31FL3190(Typical)
Figure 5 Writing to IS31FL3190(Automatic Address Increment)
REGISTERS DEFINITIONS
Table 2 Register Function
Address Name Function Table Default
00h Shutdown Register Set software shutdown mode
3
0000 0001
01h Breathing Control Register Set the breathing function
4
0000 0000
02h LED Mode Register Set operation mode 5
03h Current Setting Register Set output current 6
04h PWM Register
PWM duty cycle data setting in PWM
Control Mode
7
PWM duty cycle data setting in One Shot
Programming Mode
8
07h PWM Update Register Load PWM Register data
- xxxx xxxx
0Ah T0 Register Set the T0 time 9
0000 0000
10h T1&T2 Register Set the T1&T2 time 10
16h T3&T4 Register Set the T3&T4 time
11
1Ch Time Update Register Load time registers’ data - xxxx xxxx
1Dh LED Control Register OUT enable bit 12 0000 0001
2Fh Reset Register Reset all registers to default value
- xxxx xxxx
Table 3 00h Shutdown Register
Bit D7:D6 D5 D4:D1 D0
Name - EN - SSD
Default 00 0 0000 1
The Shutdown Register sets software shutdown mode
of IS31FL3190.
EN Channel Control
0 Channel disable
1 Channel enable
SSD Software Shutdown Enable
0 Normal operation
1 Software shutdown mode
IS31FL3190
Integrated Silicon Solution, Inc. www.issi.com 8
Rev.0A, 10/20/2015
Table 4 01h Breathing Control Register
Bit D7:D6 D5 D4 D3:D0
Name - RM HT -
Default 00 0 0 0000
The Breathing Control Register sets the breathing
function.
RM Ramping Mode Enable
0 Disable
1 Enable
HT Hold Time Selection
0 Hold on T2
1 Hold on T4
Table 5 02h LED Mode Register
Bit D7:D6 D5 D4:D0
Name - LED -
Default 00 0 00000
The LED Mode Register sets operation mode of
IS31FL3190.
LED LED Mode Selection
0 PWM Control Mode
1 One Shot Programming Mode
Table 6 03h Current Setting Register
Bit D7:D5 D4:D2 D1:D0
Name - CS -
Default 000 000 00
The Current Setting Register stores the maximum
current setting, I
MAX
, for all of the LED output channels.
CS Current Setting
000 42mA
001 10mA
010 5mA
011 30mA
1xx 17.5mA
Table 7 04h PWM Register
Operate in PWM Control Mode
Bit D7:D0
Name PWM
Default 0000 0000
The value in the PWM Register modulates the LEDs in
256 steps.
The value of the PWM Register decides the average
output current. The average output current may be
computed using the Formula (1):
7
0
2*][
256
n
n
MAX
OUT
nD
I
I (1)
Where D[n] stands for the individual bit value, 1 or 0, in
location n.
For example: if D7:D0 = 10110101,
I
OUT
= I
MAX
(2
0
+2
2
+2
4
+2
5
+2
7
)/256
I
MAX
is set by Current Setting Register.
Table 8 04h PWM Register
Operate in One Shot Programming Mode
Bit D7:D1 D0
Name PWM -
Default 0000 000 0
The value in the PWM Register modulates the LEDs in
128 steps.
The value of the PWM Register decides the average
output current. The average output current may be
computed using the Formula (1):
7
0
2*][
128
n
n
MAX
OUT
nD
I
I (1)
Where D[n] stands for the individual bit value, 1 or 0, in
location n.
For example: if D7:D1 = 1011010,
I
OUT
= I
MAX
(2
1
+2
3
+2
4
+2
6
)/128
I
MAX
is set by Current Setting Register.
07h PWM Update Register
The data sent to the PWM Register will be stored in
temporary registers. A write operation of “0000 0000”
value to the PWM Update Register is required to
update the register (04h).
IS31FL3190
Integrated Silicon Solution, Inc. www.issi.com 9
Rev.0A, 10/20/2015
Table 9 0Ah T0 Register
Bit D7:D4 D3:D0
Name T0 -
Default 0000 0000
The T0 Registers set the T0 time in One Shot
Programming mode.
T0 T0 Setting
0000 0s
0001 0.13s
0010 0.26s
0011 0.52s
0100 1.04s
0101 2.08s
0110 4.16s
0111 8.32s
1000 16.64s
1001 33.28s
1010 66.56s
Others Unavailable
Table 10 10h T1&T2 Register
Bit D7:D5 D4:D1 D0
Name T1 T2 -
Default 000 0000 0
The T1&T2 Registers set the T1&T2 time in One Shot
Programming mode.
T1 T1 Setting
000 0.13s
001 0.26s
010 0.52s
011 1.04s
100 2.08s
101 4.16s
110 8.32s
111 16.64s
T2 T2 Setting
0000 0s
0001 0.13s
0010 0.26s
0011 0.52s
0100 1.04s
0101 2.08s
0110 4.16s
0111 8.32s
1000 16.64s
Others Unavailable
Table 11 16h T3&T4 Register
Bit D7:D5 D4:D1 D0
Name T3 T4 -
Default 000 0000 0
The T3&T4 Registers set the T3&T4 time in One Shot
Programming mode.
T3 T3 Setting
000 0.13s
001 0.26s
010 0.52s
011 1.04s
100 2.08s
101 4.16s
110 8.32s
111 16.64s
T4 T4 Setting
0000 0s
0001 0.13s
0010 0.26s
0011 0.52s
0100 1.04s
0101 2.08s
0110 4.16s
0111 8.32s
1000 16.64s
1001 33.28s
1010 66.56s
Others Unavailable
1Ch Time Update Register
The data sent to the time registers will be stored in
temporary registers. A write operation of “0000 0000”
value to the Time Update Register is required to
update the registers (0Ah, 10h, 16h).