PPTE
SPECIFICATIONS CASE OUTLINE
Performance Specifications
(1)
Accuracy: (from -40 to 85ºC)
Digital: ±0.10% FS Typ., ±0.20% FS Max.
(2)
Analog: ±0.12% FS Typ., ±0.24% FS Max.
(2)
Temperature: ±1ºC (at sensing element)
Temperature Range:
Operating -40 to 85ºC (-40 to 185ºF)
Storage: -55 to 90ºC (-67 to 194ºF)
Sample Rate
(4)
: 8.33ms to 51.2 min
Resolution:
Digital: Up to 0.0011% FS
Analog: 1.22mV steps (12 bits)
Response Delay:
(1000/update rate) +1ms, minimum 17ms
Mechanical Specifications
Pressure Ranges and Type:
See Ordering Information
Pressure Units
(4)
: atm, bar, cmwc, ftwc, hPa, inHg,
inwc, kg/cm², KPa, mBar, mmHg, MPa, mwc, psi,
user, Icom, pfs
Media Compatibility: Suitable for media compatible
with 316 stainless steel (Consult factory for Hastelloy
diaphragm.)
Weight: 22 oz. (624 gm) NPT w/pigtail style
Electrical Specifications
Output:
RS-232 Digital w/0-5VAnalog
(4)
RS-485 Digital w/0-5V Analog
(4)
Power Requirements:
Supply Voltage: 6 to 30 VDC
Operating Current: Standard: 19-27mA
Baud Rate
(4)
: 1200, 2400, 4800, 9600,
14400, 19200, 28800
Bus Addressing
(4)
: Address up to 89 units.
Industrial Emissions and Immunity:
Meets IEC 61326
Environmental Features
(3)
Overpressure: 3x FS, maximum 6000psi
Burst Pressure: 3x FS, maximum 8500psi
Mechanical Shock: 1500g, 0.5ms half sine
Temp Shock: 24 1-hour cycles, -40 to 85ºC
Vibration: 0.5in or 20G’s, 20Hz – 2K Hz
PPTE Precision Pressure Transducer – Explosion Proof
FULL SCALE PRESSURE RANGE
Absolute Gauge
TYPE P1 Pressure P2 Pressure
A Absolute 0 (vacuum) to FS N/A
G Gauge Reference to FS Reference
2V RS-232 digital, 0-5V analog
5V RS-485 digital, 0-5V analog
ELECTRICAL CONFIGURATION AND CONNECTION
D ½ - 14 NPT external w/4ft pigtail cable
EXPLOSION PROOF CERTIFICATION
C CSA, Canadian Standards Association
Class I, Div I, Groups B, C, D; Class II/III, Div I, Groups E, F, G
Class I, Div I, Groups B, C, D; Class II/III, Div I, Groups E, F, G
(1) Accuracy is the sum of worst case linearity, repeatability,
hysteresis, thermal effects and calibration errors from -40 to
85ºC. Typical is the average of absolute value of errors at
all pressures and temperatures. Calibration is traceable to
NIST. (2) Tighter accuracy available on some models.
Consult factory. (3) Exposure to overpressure will not
permanently affect calibration or accuracy of unit.
Exceeding burst pressure may result in media escape.
Mechanical Shock tested per MIL-STD-883D, M2002.3,
Cond. B. Vibration tested per MIL-STD-883D, M2007.2,
Cond. A. (4) User configurable.
Honeywell Aerospace
Honeywell International Inc.
12001 Highway 55
Plymouth, MN 55441
www.honeywell.com
ADS-14182
June 2009
©2009 Honeywell International Inc.
Find out more
For more information on Honeywell’s Precision Pressure Transducers visit us online at www.honeywell.com/pressuresensing
or contact us at 800-323-8295 or 763-954-2474. Customer Service Email: ps.customer.support@honeywell.com.
Honeywell reserves the right to make changes to improve reliability, function or design. Honeywell does not assume any liability arising out of the
application or use of any product or circuit described herein; neither does it convey any license under its patent rights nor the rights of others. Covered
by one or more of the following US Patents: 4,918,992, 4,788,521 and 5,948,988.