DHS-2
DHS50A
DC-DC Converters Bus Converter
.
Power Module Type
DH S 50 A 05 -O
Ordering information
1 Series name
2 Single output
3 Output wattage
4 A : DC60-160V
5 Output voltage
6 Optional
T : with Mounting hole
(f3.4 thru)
R
1 2 3 4 5 6
MODEL DHS50A05 DHS50A12 DHS50A15 DHS50A24
MAX OUTPUT WATTAGE[W] 50.0 50.4 51.0 50.4
DC OUTPUT 5V 10A 12V 4.2A 15V 3.4A 24V 2.1A
SPECIFICATIONS
MODEL DHS50A05 DHS50A12 DHS50A15 DHS50A24
INPUT
VOLTAGE[V] DC60 - 160
CURRENT[A]
*1
0.55A 0.55A 0.55A 0.55A
EFFICIENCY[%]
*1
84.0typ 86.0typ 86.0typ 86.0typ
OUTPUT
VOLTAGE[V] 5 121524
CURRENT[A] 10 4.2 3.4 2.1
LINE REGULATION[mV] 10max 24max 30max 48max
LOAD REGULATION[mV] 10max 24max 30max 48max
RIPPLE[mVp-p]
0 to +100C
*2
80max 120max 120max 120max
-40 to 0C
*2
120max 150max 150max 150max
0 to 15% Load
*2
160max 240max 240max 240max
RIPPLE NOISE[mVp-p]
0 to +100C
*2
120max 150max 150max 150max
-40 to 0C
*2
200max 200max 200max 250max
0 to 15% Load
*2
240max 300max 300max 300max
TEMPERATURE REGULATION[mV]
0 to +65C
50max 120max 150max 240max
-40 to +100C
100max 240max 300max 480max
DRIFT[mV]
*
3
20max 40max 60max 90max
START-UP TIME[ms]
200max (DCIN 110V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
*
4
Fixed (TRM pin open), adjustable by external VR or external voltage
4.50 - 6.00 10.80 - 13.20 13.50 - 16.50 21.60 - 26.40
OUTPUT VOLTAGE SETTING[V]
4.97 - 5.13 11.91 - 12.29 14.76 - 15.24 23.62 - 24.38
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION[V]
6.30 - 7.60 13.90 - 17.55 17.25 - 21.75 27.60 - 34.80
REMOTE SENSING nothing
REMOTE ON/OFF Provided (Neqative Logic L : ON, H :OFF)
ISOLATION
INPUT-OUTPUT
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
INPUT-FG
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
OUTPUT-FG
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (20±15C)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-40 to +100C (On aluminum base plate), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
-40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max
VIBRATION
10 - 55Hz, 49.0m/s
2
(5G), 3minutes period, 60minutes each along X, Y and Z axis Complies with IEC61373 Category 1 Class B
IMPACT 196.1m/s
2
(20G), 11ms, once each along X, Y and Z axis Complies with IEC61373 Category 1 Class B
SAFETY AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1
OTHERS
CASE SIZE/WEIGHT
58.4X12.7X37.3mm [2.3X0.5X1.47 inches] (WXHXD) / 60g max
COOLING METHOD Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
*1 At rated input(DC110V) and rated load.
*2 Ripple and ripple noise is measured by using measuring board. Refer to the manual
*3 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
*4 Refer to the manual for input range.
*
Providing heat sink
as option
DHS
me_dhs.indd DHS-2me dhs indd DHS-2 2015/06/19 11:09:372015/06/19 11:09:37
DHS-3
DHS50A
External view
[0.2]
[0.3]
[0.3]
[0.3]
2-f3.5
[1.9]
[0.06]
[0.14]
[0.1]
4-f1.5
2-f2.5
Lot No.
2-M3
2-f2
[0.08]
±
0.2
4-f1
[0.04]
±0.1
-VIN
RC
+VIN
-VOUT
TRM
+VOUT
27.9
±
0.5
1.27
7.62
5.08
[0.05]
[0.3]
[0.2]
(5.0)
[0.2]
(4.7)
[0.19]
48.3
±
0.5
48.3
37.3max
58.4
[1.9]
[2.3]
max
7.62
7.62
[1.1]
[1.47]
[0.3]
[0.3]
12.7
±
0.5
5.0
[0.5]
[0.2]
±0.5
7.62
5.08
7.627.62
Div. : 0.2inch
Case(PBT)
Base Plate(Aluminum)
Name Plate
Mounting Hole
Dimensions in mm, [ ]=inches
Tolerance : ±0.3 [±0.012]
Weight : 60g max
Dimensions in mm, [ ]=inches
Mounting hole screwing torque : 0.49N
-m (5.0kgf-cm) max
(TOP VIEW)
Recomending size for processing PCB
DHS
me_dhs.indd DHS-3me dhs indd DHS-3 2015/06/19 11:09:402015/06/19 11:09:40
DHS-4
DHS100A
DC-DC Converters Bus Converter
.
Power Module Type
DH S 100 A 05 -O
Ordering information
R
1 2 3 4 5 6
1 Series name
2 Single output
3 Output wattage
4 A : DC60-160V
5 Output voltage
6 Optional
T : with Mounting hole
(f3.4 thru)
MODEL DHS100A05 DHS100A12 DHS100A15 DHS100A24
MAX OUTPUT WATTAGE[W] 100.0 100.8 100.5 100.8
DC OUTPUT 5V 20A 12V 8.4A 15V 6.7A 24V 4.2A
SPECIFICATIONS
MODEL DHS100A05 DHS100A12 DHS100A15 DHS100A24
INPUT
VOLTAGE[V] DC60 - 160
CURRENT[A]
*1
1.1A 1.1A 1.1A 1.1A
EFFICIENCY[%]
*1
85.0typ 88.0typ 88.0typ 88.0typ
OUTPUT
VOLTAGE[V] 5 121524
CURRENT[A] 20 8.4 6.7 4.2
LINE REGULATION[mV] 10max 24max 30max 48max
LOAD REGULATION[mV] 10max 24max 30max 48max
RIPPLE[mVp-p]
0 to +100C
*2
80max 120max 120max 120max
-40
to
0C
*2
120max 150max 150max 150max
0 to 15% Load
*2
160max 240max 240max 240max
RIPPLE NOISE[mVp-p]
0 to +100C
*2
120max 150max 150max 150max
-40
to
0C
*2
200max 200max 200max 250max
0 to 15% Load
*2
240max 300max 300max 300max
TEMPERATURE REGULATION[mV]
0 to +65C
50max 120max 150max 240max
-40 to +100C
100max 240max 300max 480max
DRIFT[mV]
*
3
20max 40max 60max 90max
START-UP TIME[ms]
200max (DCIN 110V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
*
4
Fixed (TRM pin open), adjustable by external VR or external voltage
4.50 - 6.00 10.80 - 13.20 13.50 - 16.50 21.60 - 26.40
OUTPUT VOLTAGE SETTING[V]
4.97 - 5.13 11.91 - 12.29 14.76 - 15.24 23.62 - 24.38
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION[V]
6.30 - 7.60 13.90 - 17.55 17.25 - 21.75 27.60 - 34.80
REMOTE SENSING nothing
REMOTE ON/OFF Provided (Neqative Logic L : ON, H :OFF)
ISOLATION
INPUT-OUTPUT
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
INPUT-FG
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C)
OUTPUT-FG
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (20±15C)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-40 to +100C (On aluminum base plate), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
-40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max
VIBRATION
10 - 55Hz, 49.0m/s
2
(5G), 3minutes period, 60minutes each along X, Y and Z axis Complies with IEC61373 Category 1 Class B
IMPACT 196.1m/s
2
(20G), 11ms, once each along X, Y and Z axis Complies with IEC61373 Category 1 Class B
SAFETY AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1
OTHERS
CASE SIZE/WEIGHT
58.4X12.7X37.3mm [2.3X0.5X1.47 inches] (WXHXD) / 60g max
COOLING METHOD Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
*1 At rated input(DC110V) and rated load.
*2 Ripple and ripple noise is measured by using measuring board. Refer to the manual.
*3 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
*4 Refer to the manual for input range.
*
Providing heat sink
as option
DHS
me_dhs.indd DHS-4me dhs indd DHS-4 2015/06/19 11:09:412015/06/19 11:09:41

DHS200A15-T

Mfr. #:
Manufacturer:
Cosel
Description:
Isolated DC/DC Converters 200W 15V 13.4A Through Hole
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union