ASF1400

www.sensirion.com Sensirion AG, Laubisrütistrasse 50, CH-8712 Stäfa ZH, Switzerland, Phone: +41 44 306 40 00, Fax: +41 44 306 40 30
ASF1400
Bidirectional Mass Flow Meter
_ Unique dynamic range:
0.01 sccm – 400 sccm
_ Outstanding resolution and accuracy
_ Ultra fast response time
_ Hysteresis & offset free
_ Calibrated & temperature compensated
_ RS-232 and
ASF1400 Product Summary
The ASF1400 Mass Flow Meter enables extremely
accurate bidirectional measurement of gas flow over four
orders of magnitude. Its leading performance is based on
SENSIRION’s unsurpassed CMOSens
®
sensor technology.
With CMOSens
®
, the on-chip sensor element forms an
integrated whole with the amplification and A/D converter
circuit. This results in superior resolution, fast response
time and large dynamic range at lowest power
consumption.
All measurement data is fully calibrated and temperature
compensated by means of an internal microcontroller.
Mounted in rugged, chemically inert PBT housing the
ASF1400 is suitable for a wide range of applications. Such
include mass flow metering for process control, medical
applications, heating ventilation and air conditioning
(HVAC) solutions, as well as gas flow metrology.
The sensor housing provides two inlets for measuring the
gas flow and withstands overpressures of 2 bar (29 psi).
The ASF1400 requires a supply voltage of 7…18Vdc and
provides an RS-232 compliant electrical interface.
Version 2.2 / November
MASS FLOW
VOLTAGE
REGULATOR
MICRO
CONTROLLER
RS232 LINE
DRIVER/
RECEIVER
EEPROM
GND
VDD
/CS
MOSI
MISO
SCK
RxD
TxD
MASS FLOW
ASF1400 MASS FLOW METER
SPI
Interface
RS232
Interface
Power
Supply
CMOSens
SENSOR CHIP
THERMAL
SENSOR
AMPLIFIER
ADC
no longer
supported
Figure 1: Block Diagram ASF1400 Mass Flow Sensor with CMOSens
®
technology.
ASF1400 Bidirectional Mass Flow Meter
Introductory Description
The heart of the ASF1400 mass flow meter is
powered by Sensirion’s unsurpassed CMOSens
®
sensor technology. The ASF1400 mass flow meter
therefore provides unbeatable performance at very
attractive system cost. The lowest detectable gas flow
rate is 0.003 sccm, which means a minimum volume
of 3 mm
3
gas per minute can be measured. Covering
at the same time a flow range of more than 4 orders
of magnitude, the ASF1400 sets a new standard
wherever mass flow has to be measured or
controlled.
The ASF1400 device measures true mass flow
independent of the ambient temperature and pressure
changes. You simply connect the gas to be measured
to the ASF1400 device to get an instantaneous gas
flow rate at a sampling rate of up to 7Hz (please
contact us for sampling rates of up to 200Hz).
A flow range between ±400 sccm can directly be
mea-sured by connecting the ASF1400. To increase
the range, a bypass can be used in conjunction with
the ASF1400 device (see Section 1.4 of this data
sheet).
In addition to mass flow, the ASF1400 device
provides information about the temperature on the
CMOSens
®
sensor element. Both mass flow and
temperature data are accessed through an RS-232.
The RS-232 interface allows you to directly connect
the ASF1400 device to a PC or PDA using standard
terminal software. If a special interface such as 4-20
mA current output or other is required contact
Sensirion for a customer specific solution.
In general, all gas types can be measured using the
ASF1400 product. However, the standard calibration
gas is nitrogen. Please contact SENSIRION, if you
would like to use the sensor for applications with other
gases.
To get you started quickly, an evaluation package
including ASF1400 devices, software, cables, rubber
hose and bypass is available from Sensirion AG.
CMOSens
®
sensor technology
CMOSens
®
is the base technology for all Sensirion
multi sensor modules and sensor systems. The
unification of semiconductor chip and sensor
technology serves as a platform for highly integrated
system solutions with excellent sensor precision and
reliability. With CMOSens
®
, the on-chip sensor
element forms an integrated whole with a high-end
amplification and A/D converter circuit. Due to the
compact single-chip design, CMOSens
®
based
sensors are very resistant to electromagnetic
disturbances (EMC), another important technical
advantage of this state of the art sensor technology.
As a result, CMOSens
®
based multi sensor modules
offer excellent sensor precision, fast response time
and a very large dynamic measurement range. In
addition, the digital intelligence of the CMOSens
®
sensor technology enables digital interfaces that
permit an easy link with the system of the customer, a
real advantage and benefit that results in ready-to-use
problem solutions (“Mount&Sense”).
www.sensirion.com Version 2.2 2/9
ASF1400 Bidirectional Mass Flow Meter
1 Mass Flow Sensor Performance
Table 1: Overview of ASF1400 Gas Sensor Performance
1
Parameter Condition Minimum
Typical
Maximu
m
Units
Flow Sensor
direct measurement -400 400 sccm
( )2
using proposed bypass tube
(2 )3
-100 100 liter/min
( )4
Dynamic Range
customized bypass tube unlimited
unlimited
Resolution 400 sccm flow 0.09 sccm
< 10 sccm flow 0.01 sccm
Lowest Detectable
Flow
< 10 sccm flow 0.015
(4)
sccm
Pressure Drop 400 sccm, p
abs.
= 1 bar 120 Pa
( )5
Repeatability
0.0025 % FS
( ) 6
0.025 % m.v.
0…5 % of full scale 0.05 % FS
( ) 7
Accuracy 23 C
5…100 % of full scale
1 % m.v.
( ) 7
Offset 23°C < 0.005 < 0.02 % FS
Overpressure
Resistance
2 bar
( )8
depends on resolution setting
142 1280 ms
Response Time
( )9
(see Section 3, Table 2)
Operating
Temperature
0 70 °C
Zero < 0.005 % FS / °C Ambient
Temperature
Coefficient
Span < 0.08
% measured value /
°C
Position Sensitivity p =1 bar, small nitrogen flow ±0.008 % FS
abs
Temperature
Sensor
Measures temperature inside the sensor, but not of the surrounding air
(10 )10
Dynamic Range 0 70 °C
Resolution 0.1 °C
Accuracy 3 2 °C
1
All data apply for calibration conditions (20°C, 1013 mbar) unless otherwise noted.
2
1 sccm = 1 cm
3
/min at 0°C and 1013mbar pressure (1sccm = 0.001 norm liter)
3
using bypass tube included in Sensirion’s mass flow meter evaluation kit EK-F1
4
1 liter/min = 1000 sccm
5
1 bar = 100 000 Pa = 0.9869 atm = 401.9 inch H
2
O = 14.5 psi
6
Error = % of full scale (FS) or % of measured value, whichever is bigger.
7
Better calibration available for high volume OEM on request. Allow the Sensor to warm up for best results.
8
For higher overpressure resistance versions please check the EM1 product page.
9
For faster response times please check out the ASF1430 high speed mass flow meter data sheet
The sensor warms up by about 7°C (depending on supply voltage and ventilation).
10
www.sensirion.com Version 2.2 3/9

ASF1400

Mfr. #:
Manufacturer:
Sensirion
Description:
Flow Sensors Sensor device
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet