TL071 Absolute maximum ratings and operating conditions
3/15
2 Absolute maximum ratings and operating conditions
Table 1. Absolute maximum ratings
Symbol Parameter
Value
Unit
TL071M, AM, BM TL071I, AI, BI TL071C, AC, BC
V
CC
Supply voltage
(1)
±18 V
V
i
Input voltage
(2)
±15 V
V
id
Differential input voltage
(3)
±30 V
R
thja
Thermal resistance junction to
ambient
(4) (5)
SO-8
DIP8
125
85
°C/W
R
thjc
Thermal resistance junction to
case
(4) (5)
SO-8
DIP8
40
41
°C/W
Output short-circuit duration
(6)
Infinite
T
oper
Operating free-air temperature range -55 to +125 -40 to +105 0 to +70 °C
T
stg
Storage temperature range -65 to +150 °C
ESD
HBM: human body model
(7)
500 V
MM: machine model
(8)
200 V
CDM: charged device model
(9)
1500 V
1. All voltage values, except differential voltage, are with respect to the zero reference level (ground) of the supply voltages
where the zero reference level is the midpoint between V
CC
+
and V
CC
-
.
2. The magnitude of the input voltage must never exceed the magnitude of the supply voltage or 15 volts, whichever is less.
3. Differential voltages are the non-inverting input terminal with respect to the inverting input terminal.
4. Short-circuits can cause excessive heating. Destructive dissipation can result from simultaneous short-circuits on all
amplifiers.
5. Rth are typical values.
6. The output may be shorted to ground or to either supply. Temperature and/or supply voltages must be limited to ensure
that the dissipation rating is not exceeded.
7. Human body model: 100 pF discharged through a 1.5 kΩ resistor between two pins of the device, done for all couples of pin
combinations with other pins floating.
8. Machine model: a 200 pF cap is charged to the specified voltage, then discharged directly between two pins of the device
with no external series resistor (internal resistor < 5 Ω), done for all couples of pin combinations with other pins floating.
9. Charged device model: all pins plus package are charged together to the specified voltage and then discharged directly to
the ground.
Table 2. Operating conditions
Symbol Parameter TL071I, AI, BI TL071C, AC, BC Unit
V
CC
Supply voltage 6 to 36 V
T
oper
Operating free-air temperature range -40 to +105 0 to +70 °C