2215079-1

Instruction Sheet
1 of 3
© 2015 TE Connectivity family of companies
All Rights Reserved
*Trademark
TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Other logos, product, and/or company names may be trademarks of their respective owners.
PRODUCT INFORMATION
1-800-522-6752
This controlled document is subject to change.
For latest revision and Regional Customer Service,
visit our website at www.te.com.
ORIGINAL
INSTRUCTIONS
408-32200
24 SEP 15 Rev A
Figure 1
The cage assembly seating tool assemblies listed in Figure 1 are used to seat the cage assemblies listed in
Figure 1 onto the pc board. The cage assembly contains compliant pins to allow solderless pc board
installation. The seating tool assembly is not designed to seat the connector, nor a cage assembly having a
heat sink.
NOTE
Dimensions in this instruction sheet are in metric units [with U.S. customary units in brackets]. Figures are not drawn to scale.
1. SETUP
1. A pc board support must be used to provide proper support for the pc board and to protect the pc
board and the cage assembly and connector from damage. Design the pc board support using the
following recommendations:
at least 25.4 mm [1 in.] longer and wider than the pc board
has flat surfaces with holes or a channel large enough and deep enough to receive any protruding
components of the cage assembly
2. Power for seating tool must be provided by an application tool (with a ram) capable of supplying a
downward force of 44.5 N [10 lb-force] per contact. For available application tools, call the number at
the bottom of this page.
CAUTION
Over-driving of the cage assembly will deform parts critical to the quality of the connection. Maximum force occurs prior to the
cage assembly bottoming on the pc board.
3. When setting up equipment to seat the cage assembly, pay particular attention to the following:
seating tool assembly must be matched to cage assembly
seating tool, cage assembly, and application tool ram must be properly aligned before cycling the
application tool
CAUTION
If the seating tool assembly and cage assembly are mismatched or are improperly aligned, damage could occur to the tooling,
cage assembly, or both.
CFP2 and CFP4 Cage Assembly Seating Tool
Assemblies 2215079-[ ] and 2215081-[ ]
(For Use Without Heat Sink)
Connector Not Shown
SEATING TOOL
ASSEMBLY
CAGE ASSEMBLY
CONFIGURATION
2215079-1
CFP2 11
2215079-2
CFP2 12
2215081-1
CFP4 11
2215081-4
CFP4 14
Compliant Pin
PC Board
Support (Ref)
Printed Circuit (PC)
Board (Ref)
Wall Support (14 Shown)
(Shown Not Installed)
Cage Assembly
(14 Shown, Ref)
Seating Tool (14 Shown)
(Bottomed on Cage Assembly)
Back of
Seating Tool
408-32200
Rev A
2 of 3
tool seating height must be set to the dimension given in Figure 2 (application tool shut height will
equal the tool seating height plus the combined thicknesses of the pc board and pc board support).
NOTE
After seating, a gap of no more than 0.10 mm [.004 in.] between the cage assembly standoffs and the pc board is allowed.
Use the tool seating height as a reference starting point. This height may need to be adjusted to obtain the amount allowed
between the standoffs of the cage assembly and the pc board.
Figure 2
4. Slide the wall support into the ports of the cage assembly until the wall support is secure. Refer to
Figure 1.
2. SEATING (See Figure 2)
NOTE
The connector and connector cover assembly must be mounted on the pc board before seating the cage assembly.
1. Place the pc board on the pc board support.
2. Orient the seating tool over the cage assembly so that the back is aligned with the back of the cage
assembly. Then lower the seating tool onto the cage assembly, making sure that the cutouts slide
over the protruding components of the cage assembly, until the seating tool bottoms on the top of the
cage assembly.
3. Place the cage assembly (with the wall support) on the pc board so that the compliant pins are aligned
and started into the matching holes in the pc board.
4. Center the seating tool (with the cage assembly with wall support) under the ram of the application
tool. Slowly lower the ram until it just meets the seating tool. Verify alignment of pc board, pc board
support, cage assembly, and seating tool.
CAUTION
Damage to the pc board, seating tool assembly, or cage assembly may occur if the seating tool is not properly seated on the
cage assembly before cycling the application tool.
5. Cycle the application tool to seat the cage assembly on the pc board. Then retract the ram, and
carefully remove the seating tool by pulling it straight from the cage assembly.
6. Remove the wall support from the cage assembly.
7. Check the cage assembly for proper seating according to the following:
widest section of each compliant pin is inside its intended pc board hole
if present, the gap between the standoffs and the pc board is no more than 0.10 mm [.004 in.]
Ram of Application Tool
(Fully Down)
Seating Tool Centered
Under Ram
Wall Support (Installed in
Ports of Cage Assembly
Compliant Pins Inserted into
Holes in PC Board and
PC Board Support
PC Board
PC Board Support
Tool Seating Height
38.61 mm [1.52 in.]
(Cage Assembly Seated)
Application Tool
Shut Height (Ram
Fully Down) (Refer
to Section 1, Step 3)
0.10 mm [.004 in.]
(Max) Gap Allowed
408-32200
Rev A
3 of 3
NOTE
For detailed application requirements for the cage assembly, refer to the application specification 114-32146.
3. MAINTENANCE AND INSPECTION
1. Inspect the seating tool assembly immediately upon arrival to ensure that it has not been damaged
during shipment and that it conforms to the dimensions given in Figure 3.
2. Remove dust, moisture, and contaminants with a clean, soft brush or a lint-free cloth. Do not use
objects that could damage the components.
3. When the seating tool assembly is not in use, store it in a clean, dry area.
4. Periodically inspect the seating tool assembly for damage.
SEATING TOOL
ASSEMBLY
CAGE ASSEMBLY
CONFIGURATION
DIMENSION (mm [in.])
A
B
C
D
E
F
2215079-1
CFP2 11
86.2 [3.39]
46.55 [1.83]
28.0 [1.10]
41.45 [1.63]
12.15 [.48]
95.0 [3.74]
2215079-2
CFP2 12
89.15 [3.51]
84.05 [3.31]
2215081-1
CFP4 11
71.5 [2.82]
26.05 [1.03]
25.05 [.98]
021.15 [.83]
09.25 [.36]
80.7 [3.18]
2215081-4
CFP4 14
92.65 [3.65]
87.75 [3.45]
Figure 3
4. REVISION SUMMARY
Initial release of instruction sheet
Seating Tool
Wall Support
A
B
C
D
F
E
Seating Tool Kit 1
4 Shown

2215079-1

Mfr. #:
Manufacturer:
TE Connectivity
Description:
I/O Connectors ASSY STG TL CFP2 1X1 W/O HS
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet