10 Miniature Limit Switch D4CC
Special Mounting Plates
(Limit Switches are not attached to the Plates.)
95
13.1
1.3
7
18.3
15.7
34.1
30
44
30±0.2
58.7±0.2
4-R2
25±0.2
5.1±0.2
11 dia.
D4C-P001 (For D4CC-@001)
34
(OP of WLD)
Two, M5 x 0.8
tapped hole
(See note 3.)
Note: 1. Four hexagonal flat head bolts (M5 x
0.8, length: 10) and two Allen-head
bolts (M5 x 0.8, length: 15) are included.
2. All the holes with 5.2
+0.2
/
0
dia. must be used
with M5 x 10 Allen-head bolts.
3. All the M5-tapped holes must be used with M5
hexagonal flat head bolts.
0
Four, 5.2
+0.2
dia. holes
(See note 2.)
4-R2
14.7
34.1
30
44
75
1.3
53
±1.5
9±0.2
5±0.2
9.2±0.2
30±0.2
58.7±0.2
25±0.2
15.5
9.5
28.5
34.1
30
44
95
1.3
13.1
4-R2
30±0.2
58.7±0.2
25±0.2
5.1±0.2
11 dia.
D4C-P002 (For D4CC-@002)
D4C-P020 (For D4CC-@024)
44
(OP of
WLD2)
Two, M5 x 0.8
tapped hole
(See note 3.)
Note: 1. Four hexagonal flat head bolts (M5
x 0.8, length: 10) and two Allen-
head bolts (M5 x 0.8, length: 15)
are included.
2. All the holes with 5.2
+0.2
/
0
dia. must be
used with M5 x 10 Allen-head bolts.
3. All the M5-tapped holes must be used
with M5 hexagonal flat head bolts.
0
Two, 5.1
+0.2
dia.
(for positioning), into which a
spring pin is press-fitted.
Two, M5 x 0.8
tapped hole
(See note 3.)
Note: 1. Four hexagonal flat head bolts (M5
x 0.8, length: 10), two Allen-head
bolts (M5 x 0.8, length: 15), and
two spring pins (4 x 14) are includ-
ed.
2. All the holes with 5.2
+0.2
/
0
dia. must be
used with M5 x 10 Allen-head bolts.
3. All the M5-tapped holes must be used
with M5 hexagonal flat head bolts.
0
Four, 5.2
+0.2
dia. holes
(See note 2.)
0
Four, 5.2
+0.2
dia. holes
(See note 2.)
Miniature Limit Switch D4CC 11
Precautions
Correct Use
Mounting
Make sure that the plate to which the D4CC is mounted is flat. If the
plate is warped or has protruding parts, the D4CC may not malfunc-
tion.
Mounting Holes
A maximum of 6 Switches may be group-mounted. In this case, pay
attention to the mounting direction so that the convex part of the
group-mounting guide on one Switch fits into the concave part of the
guide on the other Switch as shown in the figure below. For group
mounting, the mounting panel must have a thickness (t) of 6 mm min.
Group Mounting
Tightening Torque
Be sure to tighten each screw to the proper tightening torque as
shown in the table.
Note: By removing the two screws from the head, the head direction
can be rotated 180
°. After changing the head direction, re-tight-
en to the torque specified above. Be careful not to allow any for-
eign substance to enter the Switch.
Plug Tightening
Connect the plug connector (B) to the connector threads of the
D4CC. Then firmly turn the plug connector by hand so that the con-
nector threaded portion (C) will be completely covered by the plug
connector (B) so that space (A) will be almost 0. Do not use any
tools, such as pliers, to tighten the plug connector, otherwise the plug
connector may become damaged. Make sure, however, that the plug
connector is tightened securely, otherwise the rated degree of pro-
tection of the D4CC may not be maintained. Furthermore, the plug
connector may be loosened by vibration.
Properly Tightened Connector
25±0.1
Two, 5.2-dia. or
M5 screw holes
Group-mounting guide
(Front: convex
Rear: concave)
16 mm
t
Mounting plate
No. Type Torque
1 M5 Allen-head bolt 4.90 to 5.88 N·m
2 M3.5 head mounting screw 0.78 to 0.88 N·m
3 M5 Allen-head bolt 4.90 to 5.88 N·m
(B)(C)
(A)
D4CC
(A)
(B)
D4CC
12 Miniature Limit Switch D4CC
Operation
Operation method, shapes of cam and dog, operating frequency, and
overtravel have a significant effect on the service life and precision of
a Limit Switch. For this reason, the dog angle must be 30
° max., the
surface roughness of the dog must be 6.3S min. and hardness must
be Hv400 to 500.
To allow the plunger-type actuator to travel properly, adjust the dog
and cam to the proper setting positions. The proper position is where
the plunger groove fits the bushing top.
To allow the roller lever-type actuator to travel properly, adjust the
dog and cam so that the arrow head is positioned between the two
convex markers as shown below.
Properly adjust the stroke of the center roller lever along with the dog
or cam so that the concave part (A) of the head is located between
the convex parts of the head as shown below when the center roller
lever is pressed by the dog or cam.
Refer to the following to adjust the stroke of the lever based on the
mounting hole level.
Others
If failures, such as reset failures, in the plunger model are possible,
use a model that has a rubber cap.
Do not expose the Switch to water exceeding 70
°C or use it in steam.
2.8 mm
Dog
Groove
Bushing top
Arrow head
Convex
marker
A
A
Convex parts of head
Proper
range
Proper
range
Proper
range
Proper
range
Proper
range
Proper
range
44.9 (TTP)
65.3 to 64.6
(OP)
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. C116-E1-02

D4CC-4024-B

Mfr. #:
Manufacturer:
Omron Electronics
Description:
Basic / Snap Action Switches Limit SW, Roller lever
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union