Page:13/15
5. Reliability Test Items
(Note3)
Item Test Conditions Remark
High Temperature Storage
Ta = 7 0 240hrs
Note 1Note 4
Low Temperature Storage
Ta = - 30 240hrs
Note 1Note 4
High Temperature Operation
Ts = 60 240hrs
Note 2Note 4
Low Temperature Operation
Ta = - 20 240hrs
Note 1Note 4
Operate at High Temperature
and Humidity
+40, 90%RH 240hrs
Note 4
Thermal Shock
-30/30 min ~ +70/30 min for a total 100
cycles, Start with cold temperature and end
with high temperature.
Note 4
Vibration Test
Frequency range:10~55Hz
Stroke:1.5mm
Sweep:10Hz~55Hz~10Hz
2 hours for each direction of X. Y. Z.
(6 hours for total)
Mechanical Shock
100G 6ms,±X, ±Y, ±Z 3 times for each
direction
Package Vibration Test
Random Vibration :
0.015G*G/Hz from 5-200HZ, -6dB/Octave
from 200-500HZ
2 hours for each direction of X. Y. Z.
(6 hours for total)
Package Drop Test
Height:60 cm
1 corner, 3 edges, 6 surfaces
Electro Static Discharge ± 2KV, Human Body Mode, 100pF/1500
Note 1: Ta is the ambient temperature of samples.
Note 2: Ts is the temperature of panel’s surface.
Note 3: In the standard condition, there shall be no practical problem that may affect the
display function. After the reliability test, the product only guarantees operation,
but don’t guarantee all of the cosmetic specification.
Note 4: Before cosmetic and function test, the product must have enough recovery time,
at least 2 hours at room temperature.
Page:14/15
6. General Precautions
6.1. Safety
Liquid crystal is poisonous. Do not put it in your mouth. If liquid crystal touches your
skin or clothes, wash it off immediately by using soap and water.
6.2. Handling
1. The LCD panel is plate glass. Do not subject the panel to mechanical shock or to
excessive force on its surface.
2. The polarizer attached to the display is easily damaged. Please handle it
carefully to avoid scratch or other damages.
3. To avoid contamination on the display surface, do not touch the module surface
with bare hands.
4. Keep a space so that the LCD panels do not touch other components.
5. Put cover board such as acrylic board on the surface of LCD panel to protect
panel from damages.
6. Transparent electrodes may be disconnected if you use the LCD panel under
environmental conditions where the condensation of dew occurs.
7. Do not leave module in direct sunlight to avoid malfunction of the ICs.
6.3. Static Electricity
1. Be sure to ground module before turning on power or operating module.
2. Do not apply voltage which exceeds the absolute maximum rating value.
6.4. Storage
1. Store the module in a dark room where must keep at 25±10 and 65%RH or
less.
2. Do not store the module in surroundings containing organic solvent or corrosive
gas.
3. Store the module in an anti-electrostatic container or bag.
6.5. Cleaning
1. Do not wipe the polarizer with dry cloth. It might cause scratch.
2. Only use a soft sloth with IPA to wipe the polarizer, other chemicals might
permanent damage to the polarizer.
Page:15/15
7. Mechanical Drawing
4
12.55
3.530.5
5
6.35
2.01
3.31
75.8
120.7
67.4(bezel open)
110.7(Bezel open)
64.8(Active Area)
108(Active Area)
3.1 MAX
A
B
序号
更 改 记 录
记录人
日 期
比 例
单 位
投影方式:
标准公差:
0.20
准:
核:
图:
Standard tolerance:
日 期:
客户编号:
产品编号:
1:1
SCALE
UNITS
VIEW:
APPROVED BY:
DRAWN BY:
CHECKED BY:
TITLE:
VERSION NUMBER:
版本号:
DATE:
CUSTOMER ID:
mm
RX050A-04

EA-LCD-012

Mfr. #:
Manufacturer:
Embedded Artists
Description:
Display Development Tools 5" TFT 480 x 272 DISPLAY KIT