www.vishay.com
4
Document Number: 70037
S11-0800-Rev. J, 25-Apr-11
Vishay Siliconix
DG201B, DG202B
This document is subject to change without notice.
THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Notes:
a. Refer to PROCESS OPTION FLOWCHART.
b. Room = 25 °C, Full = as determined by the operating temperature suffix.
c. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
d. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
e. Guaranteed by design, not subject to production test.
f. V
IN
= input voltage to perform proper function.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
SPECIFICATIONS (for Single Supply)
a
Parameter Symbol
Test Conditions
Unless Specified
V+ = 12 V, V- = 0 V
V
IN
= 2.4 V, 0.8 V
f
Temp.
b
Typ.
c
A Suffix
- 55 °C to 125 °C
D Suffix
- 40 °C to 85 °C
Unit Min.
d
Max.
d
Min.
d
Max.
d
Analog Switch
Analog Signal Range
e
V
ANALOG
Full 0 12 0 12 V
Drain-Source
On-Resistance
R
DS(on)
V
D
= 3 V, 8 V, I
S
= 1 mA
Room
Full
90 160
200
160
200
Dynamic Characteristics
Tur n -On Ti m e t
ON
V
S
= 8 V
see switching time test circuit
Room 120 300 300
ns
Tur n -Off T i m e t
OFF
Room 60 200 200
Charge Injection Q
C
L
= 1 nF, V
gen
= 6 V
R
gen
= 0
Room 4 pC
Power Supply
Positive Supply Current I+
V
IN
= 0 or 5 V
Room
Full
50
100
50
100
µA
Negative Supply Current I-
Room
Full
- 1
- 5
- 1
- 5
Power Supply Range for
Continuous Operation
V
OP
Full + 4.5 + 25 + 4.5 + 25 V