cui.com
CUI Inc │ SERIES: VWQBS2-SIP │ DESCRIPTION: DC-DC CONVERTER date 09/10/2012 │ page 2 of 5
INPUT
parameter conditions/description min typ max units
operating input voltage
24 V model
48 V model
9.0
18.0
24
48
36.0
72.0
Vdc
Vdc
surge voltage 1 second max.
24 V model
48 V model
-0.7
-0.7
50
100
Vdc
Vdc
short circuit input power 1.6 W
input fi lter C fi lter
OUTPUT
parameter conditions/description min typ max units
line regulation input voltage from low to high ±0.2 ±0.75 %
load regulation measured from 10% load to full load ±0.5 ±1.5 %
voltage accuracy
see derating curves
positive
negative
±1
±3
±3
±5
%
%
transient recovery time 25% load step change 25 ms
transient response deviation 25% load step change ±3 ±5 %
switching frequency 100% load, input voltage range 300 kHz
temperature coeffi cient ±0.03 %/°C
PROTECTIONS
parameter conditions/description min typ max units
short circuit protection continuous, automatic recovery
SAFETY AND COMPLIANCE
parameter conditions/description min typ max units
isolation voltage for 1 minute at 1 mA max. 1,500 Vdc
isolation resistance at 500 Vdc 1,000 MΩ
MTBF 1,000,000 hours
RoHS compliant yes
ENVIRONMENTAL
parameter conditions/description min typ max units
operating temperature -40 85 °C
storage temperature -55 125 °C
storage humidity non-condensing 95 %
temperature rise at full load 15 °C
lead temperature 1.5 mm from case for 10 seconds 300 °C
For more information, please visit the product page.