Absolute maximum ratings and operating conditions TS27M2, TS27M2A, TS27M2B
2/14 Doc ID 2306 Rev 2
1 Absolute maximum ratings and operating conditions
Table 1. Absolute maximum ratings
Symbol Parameter TS27M2x/Ax/Bx Unit
V
CC
+
Supply voltage
(1)
1. All values, except differential voltage are with respect to network ground terminal.
18 V
Vid Differential input voltage
(2)
2. Differential voltages are the non-inverting input terminal with respect to the inverting input terminal.
±18 V
V
i
Input voltage
(3)
3. The magnitude of the input and the output voltages must never exceed the magnitude of the positive
supply voltage.
-0.3 to 18 V
I
o
Output current for V
CC
+
≥ 15V ±30 mA
I
in
Input current ±5 mA
R
thja
(4)(5)
4. Short-circuits can cause excessive heating and destructive dissipation.
5. R
th
are typical values.
SO-8
DIP8
TSSOP8
125
85
120
°C/W
T
stg
Storage temperature range -65 to +150 °C
T
j
Maximum junction temperature 150 °C
ESD
HBM: human body model
(6)
6. Human body model: a 100 pF capacitor is charged to the specified voltage, then discharged through a
1.5 kΩ resistor between two pins of the device. This is done for all couples of connected pin combinations
while the other pins are floating.
500 V
MM: machine model
(7)
7. Machine model: a 200 pF capacitor is charged to the specified voltage, then discharged directly between
two pins of the device with no external series resistor (internal resistor < 5 Ω). This is done for all couples of
connected pin combinations while the other pins are floating.
100 V
CDM: charged device model
(8)
8. Charged device model: all pins and the package are charged together to the specified voltage and then
discharged directly to the ground through only one pin. This is done for all pins.
1.5 kV
Table 2. Operating conditions
Symbol Parameter
Value Unit
TS27M2C/AC/BC TS27M2I/AI/BI TS27M2M/AM/BM
V
CC
+
Supply voltage 3 to 16 V
V
icm
Common mode input voltage
range
0 to V
CC
+
- 1.5 V
Toper
Operating free air temperature
range