Features
■ Size: 8 mm diameter, 8 mm length
■ Axial leaded device
■ High voltage range up to 6 kV
■ High insulation resistance
■ RoHS compliant*
■ UL Recognized
Applications
■ Industrial equipment/electronics
■ Telecommunications electronics
■ Consumer electronics
Characteristics
2095 Series High Voltage 2-Electrode Gas Discharge Tube
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifi cations are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specifi c applications.
Test Methods per ITU-T (CCITT) K.12 and IEC 61643-311.
Characteristic
Model No.
2095-80 2095-100 2095-140 2095-160 2095-200
DC Sparkover ±20 % @ 100 V/s 800 V 1000 V 1400 V 1600 V 2000 V
Impulse Sparkover
(1)
100 V/µs
1000 V/µs
< 1100 V
< 1200 V
< 1300 V
< 1400 V
< 2100 V
< 2200 V
< 2300 V
< 2400 V
< 2700 V
< 2800 V
Insulation Resistance (IR)
(2)
............................ 250/500/1000 Vdc .............................................> 1 GΩ
Glow Voltage ................................................... 10 mA ................................................................~ 60 V
Arc Voltage ...................................................... 1 A .....................................................................~ 15 V
Capacitance..................................................... 1 MHz ...............................................................< 1.5 pF
Impulse Discharge Current
2095-80 through 2095-250 ......................... 8,000 A, 8/20 µs ................................................ 1 operation
5,000 A, 8/20 µs ................................................ 10 operations
2095-270 through 2095-600 ....................... 5,000 A, 8/20 µs ................................................ 1 operation
3,000 A, 8/20 µs ................................................ 10 operations
Alternating Discharge Current
2095-80 through 2095-250 ......................... 2 Arms, 50 Hz, 1 second ................................... 1 operation min.
10 Arms, 50 Hz, 9 cycles .................................. 1 operation min.
2095-270 through 2095-300 ....................... 3 Arms, 50 Hz, 1 second ................................... 1 operation min.
5 Arms, 50 Hz, 9 cycles .................................... 1 operation min.
2095-350 through 2095-600 2.5 Arms, 50 Hz, 1 second ................................ 1 operation min.
5 Arms, 50 Hz, 9 cycles .................................... 1 operation min.
Impulse Life ..................................................... 100 A, 10/1000 µs .............................................> 100 operations
(3)
Operating Temperature ............................................................................................................... -30 to +90 °C
Storage Temperature .................................................................................................................. -40 to +115 °C
Climatic Category (IEC 60068-1)................................................................................................ 40 / 90 / 21
Notes:
• UL Recognized component: UL File E313168.
• At delivery AQL 0.65 Level II, DIN ISO 2859.
(2)
DC Breakdown IR Measuring Voltage
800-1000 V 250 V
1400-2000 V 500 V
2500-6000 V 1000 V
(3)
Model 2095-270 and 2095-300 meet >300 operations at 100 A, 10/1000 µs.
Characteristic
Model No.
2095-250 2095-270 2095-300 2095-350 2095-400
DC Sparkover ±20 % @ 100 V/s 2500 V 2700 V 3000 V 3500 V 4000 V
Impulse Sparkover
(1)
100 V/µs
1000 V/µs
< 3500 V
< 3600 V
< 3600 V
< 3800 V
< 4100 V
< 4200 V
< 4900 V
< 5000 V
< 5300 V
< 5500 V
Characteristic
Model No.
2095-450 2095-500 2095-600
DC Sparkover ±20 % @ 100 V/s 4500 V 5000 V 6000 V
Impulse Sparkover
(1)
100 V/µs
1000 V/µs
< 5800 V
< 6000 V
< 6000 V
< 6400 V
< 7000 V
< 7800 V
(1)
Impulse Sparkover voltage is defi ned as typical values of distribution.