ACPL-P347/ACPL-W347 Data Sheet
Recommended Pb-Free IR Prole
Recommended reow condition as per JEDEC Standard, J-STD-020 (latest revision). Non-Halide Flux should be used.
Regulatory Information
The ACPL-P347/W347 is approved by the following organizations:
UL Recognized under UL 1577, component recognition program up to V
ISO
= 3750V
RMS
(ACPL-P347) and
V
ISO
= 5000V
RMS
(ACPL-W347).
CSA CSA Component Acceptance Notice #5, File CA 88324
IEC/EN/DIN
EN 60747-5-5
(Option 060 Only)
Maximum Working Insulation Voltage V
IORM
= 891V
peak
(ACPL-P347) and V
IORM
= 1140V
peak
(ACPL-
W347)
IEC/EN/DIN EN 60747-5-5 Insulation Characteristics* (Option 060)
Description Symbol
ACPL-
P347
Option
060
ACPL-
W347
Option
060
Unit
Installation classication per DIN VDE 0110/39, Table 1
for rated mains voltage ≤ 150 V
RMS
for rated mains voltage ≤ 300 V
RMS
for rated mains voltage ≤ 450 V
RMS
for rated mains voltage ≤ 600 V
RMS
for rated mains voltage ≤ 1000 V
RMS
I – IV
I – IV
I – III
I – III
I – IV
I – IV
I – IV
I – IV
I – III
Climatic Classication 40/105/21 40/105/21
Pollution Degree (DIN VDE 0110/39) 2 2
Maximum Working Insulation Voltage V
IORM
891 1,140 V
peak
Input to Output Test Voltage, Method b*
V
IORM
× 1.875 = V
PR
, 100% Production Test with t
m
=1 sec, Partial discharge < 5 pC
V
PR
1,671 2,137 V
peak
Input to Output Test Voltage, Method a*
V
IORM
× 1.6 = V
PR
, Type and Sample Test, t
m
=10 sec, Partial discharge < 5 pC
V
PR
1,426 1,824 V
peak
Highest Allowable Overvoltage*
(Transient Overvoltage t
ini
= 60 sec)
V
IOTM
6,000 8,000 V
peak
Safety-limiting values – maximum values allowed in the event of a failure
Case Temperature T
S
175 175 °C
Input Current I
S, INPUT
230 230 mA
Output Power P
S, OUTPUT
600 600 mW
Insulation Resistance at TS, V
IO
= 500V R
S
>10
9
>10
9
Ω
*Refer to IEC/EN/DIN EN 60747-5-5 Optoisolator Safety Standard section of the Broadcom Regulatory Guide to Isolation Circuits, AV02-2041EN for a detailed
description of Method a and Method b partial discharge test proles.
Note: These optocouplers are suitable for “safe electrical isolation” only within the safety limit data. Maintenance of the safety data shall be ensured by means of
protective circuits. Surface mount classication is Class A in accordance with CECC 00802.