200W Constant Current Mode LED Driver
HLG-185H-C series
File Name:HLG-185H-C-SPEC 2018-05-29
SPECIFICATION
MODEL
RATED CURRENT
RATED POWER
OUTPUT
CURRENT ADJ. RANGE
SET UP TIME
Note.4
VOLTAGE RANGE Note.3
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
OVER VOLTAGE
OVER TEMPERATURE
Can be adjusted by internal
potentiometer (A/AB type only)
1000ms/115VAC 500ms/230VAC
90 ~ 305VAC 127 ~ 431VDC
(Please refer to "STATIC CHARACTERISTIC" section)
47 ~ 63Hz
<0.75mA / 277VAC
Compliance to EN55015, EN61000-3-2 Class C ( 50% load) ; EN61000-3-3,≧ ,EAC TP TC 020GB17743 and GB17625.1
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, heavy industry level ( )surge immunity Line-Earth 4KV, Line-Line 2KV
,EAC TP TC 020
-40 ~ +80 , 10 ~ 95% RH℃
±℃ ℃
0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes;
Shut down o/p voltage with auto-recovery or re-power on to recovery
Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT
SAFETY &
EMC
PROTECTION
SHORT CIRCUIT
Constant current limiting, recovers automatically after fault condition is removed
94%
94%
94%94%
HLG-185H-C500 HLG-185H-C700 HLG-185H-C1050 HLG-185H-C1400
EMC IMMUNITY
EMC EMISSION
COLD START 55A(t =900 s measured at 50% I ) at 230VAC;
width peak Per NEMA 410
TOTAL HARMONIC DISTORTION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
℃
CONSTANT CURRENT REGION
Note.2
PACKING
NOTE
μ
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
2 units (circuit breaker of type B) / 3 units (circuit breaker of type C) at 230VAC
CURRENT TOLERANCE ±5%
CURRENT RIPPLE 5.0% max. @rated current
PF 0.9 / VAC or PF 0.96/2 VAC full load≧≧≧8 115 30 or PF 0.94/2777VAC @
(Please refer to " " )POWER FACTOR (PF) CHARACTERISTIC section
THD< 20%@ 50% load/115VAC, or 230VAC, or @ 75% load/277VAC≧≧
(Please refer to “TOTAL HARMONIC DISTORTION” section)
WORKING TEMP.
Tcase=-40 ~ +90 (Refer to "Derating Curve")℃
MAX. CASE TEMP.
Tcase=+90℃
500mA 700mA 1050mA 1400mA
200W 200.2W 199.5W 200.2W
200V ~ 400V 143V ~ 286V 95V ~ 190V 71V ~ 143V
250 ~ 500mA 350 ~ 700mA 525 ~ 1050mA 700 ~ 1400mA
2A / 115VAC 1A / 230VAC 0.85A / 277VAC
450 ~ 470V 320 ~ 340V 210 ~ 225V 160 ~ 170V
10 ~ 95% RH non-condensing
UL8750, CSA C22.2 No. 250.13-12, EN/AS/NZS 61347-1, EN/AS/NZS 61347-2-13, EN62384 independent, ;GB19510.1,GB19510.14
, J61347-1, J61347-2-13 approvedIP65 or IP67 , EAC TP TC 004
651.1K hrs min. Telcordia SR-332 (Bellcore) ; 191.9K hrs min. MIL-HDBK-217F (25 )℃
228*68*38.8mm (L*W*H)
1.15Kg; 12pcs/14.8Kg/0.8CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25 of ambient temperature.℃
2. Please refer to "DRIVING METHODS OF LED MODULE".
3. De rating may be needed under low input voltages. Please .- refer to STATIC CHARACTERISTIC sections for details
4. Length of set up time is measured at first cold start. Turning ON/OFF the may lead to increase of the set up time.driver
5. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED can only be used behind a switch without permanentlydriver
connected to the mains.
7. This series meets the typical life expectancy of >62,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75 or less.℃
8. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com.
9. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃