W91-X112-2

General Purpose Relays
Industrial Relays
W6/W9 Series Magnetic Hydraulic P&B Circuit Breakers (Continued)
11-2015, Rev. 1115
www.te.com
© 2014 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
4
Potter & BrumeldPotter & Brumeld
Product code structure Typical product code W 91- X 1 1 2- 20
W9 Series
Circuit Breaker Mounting
W #6-32 mounting threads
M M3.0 x 0.5 mounting threads
Number of Poles
91 Single Pole
92 Two Pole
93 Three Pole
94 Four Pole
Circuit Function (Only X is VDE approved)
X Series trip
Actuator
One actuator per pole
1 Black toggle
2 White toggle
Maximum Line Voltage (see Table 1 for current ranges)
UL/CSA 1 277VAC, 50/60 Hz.
Types 2 277/480VAC, 50/60 Hz. [20A Max.]
5 65VDC
7 AC/DC 277VAC, 50/60 Hz. or 65VDC
(Time delay curve 34 must be specified)
8 AC/DC 120VAC, 120/240VAC, 48VDC
(Agency Approval M [UL1500] and time delay curve 34 must be specified)
VDE 1 250VAC, 415/240VAC
Types 5 65VDC
7 AC/DC 250VAC, 415/240VAC, 65VDC
(Time delay curve 34 must be specified)
Time Delay Curve
0 Instantaneous 10 AC high inrush motor start / long delay
2 Standard delay 12 AC high inrush version of #2
3 Short delay 13 AC high inrush version of #3
53 DC high inrush 34 Combination AC/DC standard delay
Amp Rating
0.20 0.75 2.0 3.5 6.0 8.0 11.0 20.0 35.0 50.0
0.25 1.00 2.5 4.0 7.0 9.0 12.0 25.0 40.0 Consult factory for other values
0.50 1.50 3.0 5.0 7.5 10.0 15.0 30.0 45.0
Agency Approval
Blank UL1077/CSA approved breaker
V VDE approved breaker
M UL1077/UL1500 ignition protected breaker
Authorized distributors are more likely to stock the following items.
W91-X112-1 W91-X112-15 W91-X113-15 W91-X152-40 W92-X112-5 W92-X112-30 W92-X1110-30 W93-X112-30
W91-X112-2 W91-X112-20 W91-X150-5 W91-X152-50 W92-X112-7 W92-X112-40 W93-X112-5 W93-X112-40
W91-X112-3 W91-X112-40 W91-X152-10 W91-X1110-20 W92-X112-10 W92-X112-50 W93-X112-10 W93-X112-50
W91-X112-5 W91-X112-50 W91-X152-15 W92-X112-1 W92-X112-15 W92-X113-15 W93-X112-15 W93-X1110-20
W91-X112-7 W91-X113-5 W91-X152-20 W92-X112-2 W92-X112-20 W92-X113-20 W93-X112-20 W93-X1110-30
W91-X112-10 W91-X113-10 W91-X152-30 W92-X112-3 W92-X112-25 W92-X1110-20 W93-X112-25
General Purpose Relays
Industrial Relays
W6/W9 Series Magnetic Hydraulic P&B Circuit Breakers (Continued)
11-2015, Rev. 1115
www.te.com
© 2014 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
5
Potter & Brumeld
W6 Series
Outline Dimensions - Toggle Actuator Models
1.520
(38.61)
.235
(5.97)
2.043
(51.89)
1.640
(41.66)
.245
(6.22)
.66
(16.8)
ON
OFF
29°
30°
A
B
LINE
LOAD
Panel Mounting Cutout
.750
(19.05)
1.660
(42.16)
Ø .625 +.010
-.000
(
15.88 +0.25
)
-0.00
1 PER POLE
Ø .156
(3.96)
[2 PLACES PER POLE]
1.048
(26.62)
W6 Series - One Actuator Per Pole
2.000
(50.80)
6.32 TH'D. .14 (3.56) DP. TYP.
M3 X 0.5 OPTIONAL
1.22
(31. 00)
1.05
(26.67)
1.660
(42.16)
.750
(19.05)
Ø .590
(15.00)
1 Pole
1.500
(38.10)
2 Pole
2.250
(57.15)
3 Pole
4 Pole
W6 Series - One Actuator Per Unit
2.000
(50.80)
6.32 TH'D. .14 (3.56) DP. TYP.
M3 X 0.5 OPTIONAL
1.22
(31. 00)
1.05
(26.67)
1.660
(42.16)
.750
(19.05)
Ø .590
(15.00)
1 Pole
1.500
(38.10)
2 Pole
2.250
(57.15)
3 Pole
3.000
(76.20)
4 Pole
Note: Multi-pole models furnished with seperate handle tie hardware
Note: 4-pole models furnished with sperate
handle tie hardware
Notes:
1. Terminal protrusion dimensions are referenced from back of mounting panel
2. Main terminals are male quick connect type .250 (6.35) wide x .031 (.79) thick x
.377 (9.58) long. Optional 8-32 x .250 (6.35) or 10-32 x .250 (6.35) screw type
3. Panel mounting cutout detail mtg. detail tol.: ± .005 (.13) unless noted. Add
additional cutouts to correspond to number of poles. Outline drawing tolerance ±
.015 (.35) unless noted
2.250
(57.15)
2.778
(70.56)
.269
(6.83)
.266
(6.76)
2.530
(64.26)
480V Model with Barriers
Note: 3-pole model shown
Termination Options
1.058
(26.97)
2.380
(60.45)
LINE
LOAD
A
B
LINE
LOAD
1.520
(38.61)
.235
(5.97)
2.032
(51.61)
A
B
A
B
LINE
LOAD
LINE
LOAD
C
NO
NC
.416
(10.56)
.827
(21.00)
General Purpose Relays
Industrial Relays
W6/W9 Series Magnetic Hydraulic P&B Circuit Breakers (Continued)
11-2015, Rev. 1115
www.te.com
© 2014 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
6
Potter & Brumeld
W6 Series
Outline Dimensions - Optional Toggle Guards
.78
(19.8)
.20
(5.08)
.44
(11.18)
.2 x
R1.0
(25.4)
.17 REF.
(4.32)
6 x .16 DIA.
(4.06)
.75
(19.05)
.75
(19.05)
1.093
(27.76)
2.185 INSIDE
(55.50)
4 x .16 DIA.
(4.06)
.75
(19.05)
.313
(7.95)
.313
(7.95)
1.375 INSIDE
(34.92)
.625 INSIDE
(15.88)
.47
(11.94)
.625
(15.88)
2 x .16 DIA.
(4.06)
.17
(4.32)
1.66
(42.16)
2.00
(50.8)
2 x
.27 DIA.
(6.86)
.95
(24.1)
.53
(13.46)
.08
(2.03)
.03
(.76)
84-004
(for 1 Pole
Breaker)
84-005
(for 2 Pole
Breaker)
84-006
(for 3 Pole
Breaker)
84-004 toggle guard shown with
W67 series circuit breaker
mounted in a panel.
Optional toggle guards may be ordered seperately for use on W6 toggle actuator models.
These guards help to prevent accidental operation and allow the breaker to be locked in the “off” position.

W91-X112-2

Mfr. #:
Manufacturer:
TE Connectivity / Potter & Brumfield
Description:
Circuit Breakers CIRCUIT BREAKER SWITCH 2A BLACK
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union