W91-X112-10

General Purpose Relays
Industrial Relays
W6/W9 Series Magnetic Hydraulic P&B Circuit Breakers
11-2015, Rev. 1115
www.te.com
© 2014 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
1
Potter & Brumeld
n
Designed for the international market. UL Recognzied (UL1077 and
UL1500), CSA Accepted and VDE approved.
n
Ratings to 50 amps.
n
Heavy duty #10-32 stud connections. (W9)
n
Quick-connect or screw terminals. (W6)
n
Several delay curve options.
n
Trip-free operation.
Agency Approvals
UL: Recognized as Supplementary Protector under UL 1077. Available
models meet Ignition Protection requirements in accordance with
UL1500. File E69543
CSA: Accepted as a Supplementary Protector. File LR15734.
VDE: Approved to VDE 0642/EN 60 934 (Circuit Breakers for Equipment)
License No. 73782
Users should thoroughly review the technical data before selecting a product part number.
It is recommended that users also seek out the pertinent approvals files of the agencies/
laboratories and review them to confirm the product meets the requirements for a given
application.
Electrical Data
Calibration:
Breakers will hold 100% of rated current.
Breakers may trip between 101% and 124% of rated load (134% for AC/
DC units).
Breakers must trip at 125% of rated load and above (135% for AC/DC
units).
Dielectric Strength: 50/60 Hz., 1500V: DC, 1100V
Insulation Resistance: 100 Megaohms at 500VDC
Endurance:
10,000 on/off cycles - 6000 at rated load, 4000 at no load.
Units tested at six cycles per minute, 1 second on and 9 seconds off at
25°C ambient.
Typical Resistance and Impedance
Current DC 50/60
(Amps.) Resistance Impedance
(Ohms) (Ohms)
0.2 90 90
1.0 1.2 1.2
2.0 0.28 0.28
5.0 0.04 0.04
10.0 0.013 0.013
20.0 0.004 0.005
30.0 0.0027 0.004
40.0 0.002 0.002
50.0 0.0015 0.0015
Tolerance: 0.1 - 4.99 ± 15%; 5 - 9.99 ± 20%; 10 - 15 ± 25%; 16 - 30 ± 50%.
Mechanical/Environmental Data
Operating Temperature: -40°C to +85°C.
Humidity: Meets requirements of Mil-STD-202 method 103.
Shock: Tested per Mil-STD-202, method 213, test condition C
(100g @ 6 ms)
Vibration: Tested per Mil-STD-202, method 201, 10-55 Hz., 0.06”
(1.52mm) total excursion in 2 planes.
Mechanical/Environmental Data (continued)
Fungus and Moisture Resistance:
Special moisture resistant finish applied to all ferrous parts.
Plastic parts are made of inherently fungus resistant material.
Marking:
International “1” and “0” symbols are marked on the toggle for both W6 and
W9. W9 units have “ON” and “OFF” molded into the area at the base of the
toggle.
Mounting:
Units are mounted with two #6-32 screws from the front of the panel.
Metric models for use with M3 x 0.5 screws are available. To maintain
published performance specifications, units should not be mounted more
than 90° from their normal upright position.
Weight: Approximately 2.5 ounces per pole.
Approvals and Ratings Table 1
Maximum
Voltage
Frequency
(Hz)
Phase
Current
Rating
(Amps)
Interrupting
Capacity
(Amps)
65 DC - 0.2 - 50 2,000
277 50/60 1 0.2 - 20 5,000
277 50/60 1 21 - 50 2,500
277/480 50/60 3Ø-Wye 0.2 - 20 5,000
W6 Series UL1077/CSA (All Circuit Functions)
Maximum
Voltage
Frequency
(Hz)
Phase
Current
Rating
(Amps)
Interrupting
Capacity
(Amps)
65 DC - 0.2 - 50 2,000
277 50/60 1 0.2 - 50 5,000
277/480 50/60 3Ø-Wye 0.2 - 20 5,000
W9 Series UL1077/CSA (All Circuit Functions)
Maximum
Voltage
Frequency
(Hz)
Phase
Current
Rating
(Amps)
Interrupting
Capacity
(Amps)
65 DC - 0.2 - 50 2,000
250 50/60 1 0.2 - 30 5,000
250 50/60 1 31 - 50 2,000
415/240 50/60 0.2 - 30 5,000
W6 or W9 Series VDE (Circuit Function X)
Maximum
Voltage
Frequency
(Hz)
Phase
Current
Rating
(Amps)
Interrupting
Capacity
(Amps)
48 DC - 0.2 - 50 3,000
125/250 50/60 1 0.2 - 50 1,000
250 50/60 3Ø-Wye 0.2 - 50 1,000
W6 or W9 Series UL1500 (Circuit Function X)
General Purpose Relays
Industrial Relays
W6/W9 Series Magnetic Hydraulic P&B Circuit Breakers (Continued)
11-2015, Rev. 1115
www.te.com
© 2014 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
2
Potter & Brumeld
100 200 300 400 500 600 700 800 900 1000 11 00 12 00
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
125 150
10,000
1000
100
10
1
.1
.01
.001
0
TIME IN SECONDS
CURVE 0 INSTANTANEOUS
OVERLOAD @ 50/60 Hz. & DC @ 400 Hz.
125% 100 ms max. May Tr ip
150% 55 ms max. 100 ms max.
200% 30 ms max. 30 ms max.
400% 15 ms max. 15 ms max.
600% 12 ms max. 12 ms max.
800% 12 ms max. 12 ms max.
TRIP TIMES
400 Hz.
DC & 50/60 Hz.
100 200 300 400 500 600 700 800 900 1000 11 00 12 00
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
125 150
10,000
1000
100
10
1
.1
.01
.001
0
TIME IN SECONDS
CURVE 2 STANDARD DELAY 50/60 Hz.
OVERLOAD TRIP TIMES
(SEC.)
125% 10 - 150
200% 2.2 - 20
400% .2 - 2
600% .03 - .75
800% .007 - .15
1000% .005 - .04
100 200 300 400 500 600 700 800 900 1000 11 00 12 00
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
125 150
10,000
1000
100
10
1
.1
.01
.001
0
TIME IN SECONDS
CURVE 3 SHORT DELAY 50/60 Hz.
OVERLOAD TRIP TIMES
(SEC.)
125% 1 - 15
200% .15 - 1. 5
400% .03 - .25
600% .007 - .15
800% .003 - .08
1000% .003 - .04
100 200 300 400 500 600 700 800 900 1000 11 00 12 00
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
125 150
10,000
1000
100
10
1
.1
.01
.001
0
TIME IN SECONDS
MOTOR START / LONG DELAY
CURVE 10 HIGH INRUSH 50/60 Hz. AC
OVERLOAD TRIP TIMES
(SEC.)
125% 40 - 500
200% 9 - 100
400% 2 - 20
600% .8 - 10
800% .1 - 4.5
1000% .009 - 2
100 200 300 400 500 600 700 800 900 1000 11 00 12 00
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
125 150
10,000
1000
100
10
1
.1
.01
.001
0
TIME IN SECONDS
CURVE 12 HIGH INRUSH 50/60 Hz.
125% 10 - 150
200% 3 - 25
400% .5 - 2.5
600% .15 - 1
800% .015 - .7
1000% .009 - .35
OVERLOAD TRIP TIMES
(SEC.)
100 200 300 400 500 600 700 800 900 1000 11 00 12 00
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
125 15 0
10,000
1000
100
10
1
.1
.01
.001
0
TIME IN SECONDS
CURVE 13 HIGH INRUSH 50/60 Hz.
OVERLOAD TRIP TIMES
(SEC.)
125% .8 - 30
200% .15 - 2.5
400% .03 - .3
600% .02 - .15
800% .009 - .12
1000% .009 - .09
100 200 300 400 500 600 700 800 900 1000 11 00 12 00
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
125 150
10,000
1000
100
10
1
.1
.01
.001
0
TIME IN SECONDS
CURVE 2 STANDARD DELAY DC
OVERLOAD TRIP TIMES
(SEC.)
125% 2 - 55
200% .60 - 8
400% .1 - 1. 5
600% .02 - .5
800% .004 - .05
1000% .004 - .025
100 200 300 400 500 600 700 800 900 1000 11 00 12 00
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
125 150
10,000
1000
100
10
1
.1
.01
.001
0
TIME IN SECONDS
CURVE 3 SHORT DELAY DC
OVERLOAD TRIP TIMES
(SEC.)
125% .6 - 7
200% .16 - 1.5
400% .03 - .25
600% .01 - .13
800% .004 - .05
1000% .003 - .015
100 200 300 400 500 600 700 800 900 1000 11 00 12 00
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
125 150
10,000
1000
100
10
1
.1
.01
.001
0
TIME IN SECONDS
CURVE 53 DC HIGH INRUSH
OVERLOAD TRIP TIMES
(SEC.)
125% 80 - 700
200% 15 - 150
400% 2 - 20
600% .70 - 10
800% .10 - 3
1000% .01 - .1
100 200 300 400 500 600 700 800 900 1000 11 00 12 00
LOAD CURRENT AS A PERCENT
OF BREAKER RATING
125 150
10,000
1000
100
10
1
.1
.01
.001
0
TIME IN SECONDS
CURVE 34 DC, 50/60 Hz. STANDARD DELAY
OVERLOAD TRIP TIMES
(SEC.)
135% 1 - 90
200% .60 - 20
400% .095 - 2
600% .02 - .95
800% .002 - .45
1000% .002 - .09
135
AC 50/60 Hz.
DC
AC/DC
Note:
For instantaneous curves for all voltages refer to Curve 0 instananeous under the AC 50/60 Hz. heading
Time vs Current Trip Curves For W6 Series and W9 Series
General Purpose Relays
Industrial Relays
W6/W9 Series Magnetic Hydraulic P&B Circuit Breakers (Continued)
11-2015, Rev. 1115
www.te.com
© 2014 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
3
Potter & BrumeldPotter & Brumeld
Product code structure Typical product code W 67- X 2 Q 1 2- 20
W6 Series
Circuit Breaker Mounting
W #6-32 mounting threads
M M3.0 x 0.5 mounting threads
Number of Poles
67 Single Pole
68 Two Pole
69 Three Pole
70 Four Pole
Circuit Function (Only X is VDE approved)
X Series trip
Actuator
One actuator per pole
1 Black toggle 9 Red toggle
2 White toggle
One actuator per unit
7 Black toggle 8 White toggle
Termination
Q .250“ QC (DIN 46 244) [30A Max. UL/CSA; 25A Max. VDE]
S #8-32 screw [30A Max.]
T #10-32 screw [50A Max.]
U #8-32 screw, nickel plated, bent inward 30° [30A Max.]
V #10-32 screw, nickel plated, bent inward 30° [30A Max.]
Notes:
#10-32 termination must be used for all ratings of greater than 30 amps.
#10-32 termination must be specified for circuit function D, but relay trip pole will be equipped
with .250“ QC.
Maximum Line Voltage (see Table 1 for current ranges)
UL/CSA 1 277VAC, 50/60 Hz.
Types 2 277/480VAC, 50/60 Hz. [20A Max.] (Requires insulating barriers,
see outline dimension drawing)
5 65VDC
7 AC/DC 277VAC, 50/60 Hz. or 65VDC
(Time delay curve 34 must be specified)
8 AC/DC 120VAC, 120/240VAC, 48VDC
(Agency Approval M [UL1500] and time delay curve 34 must be specified)
VDE 1 250VAC, 415/240VAC
Types 5 65VDC
7 AC/DC 250VAC, 415/240VAC, 65VDC
(Time delay curve 34 must be specified)
Time Delay Curve
0 Instantaneous 10 AC high inrush motor start / long delay
2 Standard delay 12 AC high inrush version of #2
3 Short delay 13 AC high inrush version of #3
53 DC high inrush 34 Combination AC/DC standard delay
Amp Rating
0.2 0.50 1.0 2.0 3.0 4.0 6.0 7.5 9.0 11.0 15.0 25.0 35.0 45.0 Consult factory for
0.25 0.75 1.5 2.5 3.5 5.0 7.0 8.0 10.0 12.0 20.0 30.0 40.0 50.0 other values
Agency Approval
Blank UL1077/CSA breaker
V VDE approved breaker
M UL1077/UL1500 ignition protected breaker
Authorized distributors are more likely to stock the following items.
W67-X2Q10-3 W67-X2Q12-10 W67-X2Q13-3 W67-X2Q50-5 W67-X2Q52-30 W68-X2Q12-10 W68-X2Q110-10 W69-X2Q12-25
W67-X2Q10-5 W67-X2Q12-15 W67-X2Q13-10 W67-X2Q50-10 W67-X2Q110-15 W68-X2Q12-15 W68-X2Q110-20 W69-X2Q12-30
W67-X2Q12-2 W67-X2Q12-20 W67-X2Q13-15 W67-X2Q52-5 W67-X2Q110-20 W68-X2Q12-20 W69-X2Q12-5 W69-X2Q110-20
W67-X2Q12-3 W67-X2Q12-30 W67-X2Q13-20 W67-X2Q52-10 W68-X2Q12-3 W68-X2Q12-25 W69-X2Q12-10 W69-X2Q110-30
W67-X2Q12-5 W67-X2Q13-1 W67-X2Q13-25 W67-X2Q52-15 W68-X2Q12-5 W68-X2Q12-30 W69-X2Q12-15
W67-X2Q12-7 W67-X2Q13-2 W67-X2Q13-30 W67-X2Q52-20 W68-X2Q12-7 W68-X2Q13-15 W69-X2Q12-20

W91-X112-10

Mfr. #:
Manufacturer:
TE Connectivity
Description:
Circuit Breakers 10A 1 POLE 1 TOGGLE
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union