http://www.tracopower.com Page 2 of 3
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
DC/DC Converters
TMR 2WIN Series 2 Watt
Input Specifications
Input current at no load (nominal input) 12 Vin models: 60 mA typ.
24 Vin models: 30 mA typ.
48 Vin models: 20 mA typ.
Surge voltage (1 sec. max.) 12 Vin models: 25 V max.
24 Vin models: 50 V max.
48 Vin models: 100 V max.
Short circuit input power 1500 mW
Input Filter capacitor type
Recommended input fuse (DC slow blow) 12 Vin models: 1000 mA
24 Vin models: 500 mA
48 Vin models: 250 mA
Start up voltage / under voltage shutdown (hysteresis) 12 Vin models: 4.5 / 4.0 V (or lower)
long term operation with under-voltage may cause demage 24 Vin models: 9.0 / 8.0 V (or lower)
48 Vin models: 18 / 16 V (or lower)
Recommended input fuse (DC slow blow) 12 Vin models: 1000 mA
24 Vin models: 500 mA
48 Vin models: 250 mA
Output Specifications
Voltage set accuracy ±2 %
Regulation – Input variation Vin min. to Vin max. 0.5 % max.
– Load variation 0 – 100 % single output models: 1.0 % max.
dual output models: 2.0 % max. (balanced load)
Minimum load no minimum load required
Temperature coefficient ±0.02 %/°C
Ripple and noise (20 MHz Bandwidth) 100 mVp-p max
Transient response (25 % load step change) 500 µs max.
Short circuit protection continuous (automatic recovery)
Capacitive load 3.3 VDC / 5 VDC models: 1’000 µF max.
12 VDC models: 170 µF max.
15VDC models: 110 µF max.
±5 VDC models: 470 µF max.
±12 VDC models: 100 µF max. (each output)
±15 VDC models: 47 µF max. (each output)
General Specifications
Temperature ranges – Operating
(natural convection 20 LFM)
–40°C to +90°C
– Case temperature +105°C max.
– Storage –55°C to +125°C
Derating (convection cooling) 3.3 %/K above 75°C
Humidity (non condensing) 95 % rel. H max.
Reliability, calculated MTBF (MIL-HDBK-217F at +25°C, ground benign) >1 Mio h
Isolation voltage (60 sec.) – Input/Output 1’500 VDC
Isolation capacitance – Input/Output 500 pF max.
Isolation resistance – Input/Output (500 VDC) >1‘000 M Ohm
Switching frequency 300 kHz (PFM)
Safety standards CAN/CSA-C22.2 No 60950-1-07, 2nd ed; A1:2011
ANSI/UL No. 60950-1, 2nd ed.; A1:2011
IEC 60950-1:2005 (2nd edition); Am 1:2009
EN 60950-1:2006/A11:2009/A1:2010/A12:2011
– Certification documents www.tracopower.com/overview/tmr2win