MAX702CSA+T

MAX700/MAX701/MAX702
Power-Supply Monitor with Reset
4 _______________________________________________________________________________________
Pin Description
PIN
MAX700 MAX701 MAX702
NAME FUNCTION
111MR
Input for Manual Pushbutton Reset. Has internal 5µA pullup. Low input activates the
RESET/RESET outputs.
2 SENSE
The voltage-sense input when CTL = V
CC
. Its threshold is 1.29V. SENSE always
remains connected to the internal comparator. So, when V
CC
is being monitored
internally (CTL = GND), SENSE should be left open circuit.
3 HYST
Normally NOT used when voltage is monitored through V
CC
(CTL = GND). When
monitoring through SENSE (CTL = V
CC
), HYST allows hysteresis to be added,
reducing noise and spurious reset activity (Figure 3). HYST turns on 5µs before the
RESET/RESET outputs are activated, and its on-resistance to GND is typically 1k.
4 4 3 GND Ground
567RESET
Goes low when V
CC
falls below 4.65V, or when CTL = V
CC
on the MAX700 goes low
when SENSE falls below 1.29V.
6 5 RESET Inverted Version of RESET
7 CTL
When C TL = GN D , V
C C
i s m oni tor ed b y the r eset ci r cui t. When C TL = V
C C
, V
C C
i s i g nor ed
and S E N S E i s m oni tor ed , al l ow i ng the thr eshol d to b e set w i th exter nal r esi stor s.
882V
CC
Chip Power and +5V Sensing Input (When CTL = GND on MAX700)
2, 3, 7 4, 5, 6, 8 N.C. No Connection
MAX700/MAX701/MAX702
Power-Supply Monitor with Reset
_______________________________________________________________________________________ 5
Figure 1. MAX700 Block Diagram
RESET
1M
1.29V REF
OSC
RC
R
R
COMPARATOR
RESET
GND
1
2
8
7
V
CC
CTL
SENSE
HYST
150k
MR
3
4
6
5
MAX700
GND
1
2
8
7
SENSE
MANUAL
RESET
BUTTON
HYST
MR
3
4
6
N.C.
N.C.
TO µP
+5V
5
MAX700
RESET
RESET
V
CC
CTL
GND
1
2
8
7
SENSE
MANUAL
RESET
BUTTON
HYST
MR
3
4
6
N.C.
R1
R3R2
V
IN
TO µP
V
IN
3V TO 15V
V
L
= LOWER VOLTAGE THRESHOLDR1 = R2
(
V
L
- 1
)
1.29
R3 =
V
T
R1
V
U
- V
L
V
U
= UPPER VOLTAGE THRESHOLD
HYSTERESIS = V
U
- V
L
5
MAX700
RESET
RESET
V
CC
CTL
RESET
0V
0V
2V/div
2V/div
1s/div
V
CC
Figure 4. Typical MAX700/MAX701/MAX702 RESET Output vs. V
CC
Figure 2. MAX700 Typical Connection Diagram
Figure 3. MAX700 Connected for External Senses and
Hysteresis
Figure 4 shows the RESET output of the MAX700/
MAX701/MAX702 in the correct state for V
CC
voltages
down to 0V. Note the effect of the built-in hysteresis on
the trigger lever of RESET.
Package Information
For the latest package outline information, go to
www.maxim-ic.com/packages.
MAX700/MAX701/MAX702
Power-Supply Monitor with Reset
Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are
implied. Maxim reserves the right to change the circuitry and specifications without notice at any time.
6
_____________________Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600
© 2008 Maxim Integrated Products is a registered trademark of Maxim Integrated Products, Inc.
Revision History
REVISION
NUMBER
REVISION
DATE
DESCRIPTION
PAGES
CHANGED
0 3/90 Initial release
1 11/05 Added lead-free information to the Ordering Information table. 1
2 12/07 Updated Pin Description table. 4

MAX702CSA+T

Mfr. #:
Manufacturer:
Maxim Integrated
Description:
Supervisory Circuits Power-Supply Monitor w/Reset
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: