https://www.phoenixcontact.com/us/produkte/3208553
07.05.2013Page3/17
Protective conductor double-level terminal block-PTTB 1,5/S-PE/
L-3208553
Technical data
Technical data
Conductor cross section short circuit testing 1.5 mm²
Short-time current 0.18 kA
Short circuit stability result Test passed
Ageing test for screwless modular terminal block temperature cycles 192
Result of aging test Test passed
Proof of thermal characteristics (needle flame) effective duration 30 s
Result of thermal test Test passed
Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2008-03
Test spectrum Service life test category 2, class B, on bogie
Test frequency
f
1
= 5 Hz to f
2
= 250 Hz
ASD level
11.83 (m/s
2
)
2
/Hz
Acceleration 4.25 g
Test duration per axis 5 h
Test directions X-, Y- and Z-axis
Oscillation, broadband noise test result Test passed
Test specification, shock test DIN EN 50155 (VDE 0115-200):2008-03
Shock form Half-sine
Acceleration 30 g
Shock duration 18 ms
Number of shocks per direction 3
Test directions X-, Y- and Z-axis (pos. and neg.)
Shock test result Test passed
Temperature index, insulating material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
Static insulating material application in cold -60 °C
Connection data
Conductor cross section solid min. 0.14 mm²
Conductor cross section solid max. 1.5 mm²
Conductor cross section stranded min. 0.14 mm²
Conductor cross section stranded max. 1.5 mm²
Conductor cross section AWG/kcmil min. 26
Conductor cross section AWG/kcmil max 14
Conductor cross section stranded, with ferrule without plastic sleeve min. 0.14 mm²
Conductor cross section stranded, with ferrule without plastic sleeve max. 1.5 mm²
Conductor cross section stranded, with ferrule with plastic sleeve min. 0.14 mm²
Conductor cross section stranded, with ferrule with plastic sleeve max. 1 mm²