8340-T120-K1T1-ALH126-30A

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...
www.e-t-a.de
1708 1
1
Description
Typical applications
Technical data
Single, two and three pole magnetic and hydraulic-magnetic circuit
breakers with trip-free mechanism and toggle actuation. A choice of
fast magnetic only or hydraulically delayed switching characteristics
(S-type MO or HM CBE to EN 60934) ensures suitability for a wide
range of applications. Featuring a combi-foot design for symmetric rail
mounting. Low temperature sensitivity at rated load.
Approved to CBE standard EN 60934 (IEC 60934).
Power supplies, control equipment, communication systems, EDP
systems.
8340-T...
single pole three pole
For further details please see chapter: Technical Information
Voltage rating 3 AC 415V; AC 240V (50/60Hz); DC 80V
(higher DC voltages to special order)
Current rating range 0.02...50 A DC
0.02...30 A AC
Auxiliary circuit 1 A, AC 240 V/DC 65 V; 0.5 A DC 80 V
Typical life 3 AC 415 V AC 240 V:
0.02...30 A 6,000 operations at 1 x I
N
, inductive
10,000 operations at 1 x I
N
, resistive
WDC 80 V: 0.02...25 A 6,000 operations at 1 x I
N
, inductive
0.02...30 A 10,000 operations at 1 x I
N
, resistive
40 + 50 A 6,000 operations at 1 x I
N
, resistive
Ambient temperature -40...+85 °C (-40...+185 °F)
Insulation co-ordination rated impulse pollution
(IEC 60664 and 60664A) withstand voltage degree
2.5 kV 2
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A)
operating area test voltage AC 3,000 V
Line to Load test voltage AC 1,500 V
pole to pole
(2- and 3-pole) test voltage AC 1,500 V
main to auxiliary circuit test voltage AC 1,500 V
Insulation resistance > 100 MΩ (DC 500 V)
Interrupting capacity 6 x IN at AC;
IEC 60934 - test sequence E 4 x IN at DC
Interrupting capacity I
N
0.02...20 A 25...30 A
(UL 1077) AC: 1-pole AC 250 V/3,500A AC 250 V/3,500A
2-pole AC 250 V/3,500A AC 250 V/5,000A
3-pole 3AC 250V/3,500A 3AC250V/5,000A
DC: 1-pole 0.02...50 A DC 80 V/3,500 A
2-pole 0.02...30 A DC 80 V/3500 A
Degree of protection operating area IP40
(IEC 60529/DIN 40050) terminal area IP20
Vibration
with toggle down: 10 g at 0.9 I
N
directions 1, 2, 3, 4, 5: 10 g at 1 x I
N
with curves F1, F2: 10 g at 0.8 x I
N
in all planes.
(57-2000 Hz) ± 0.76 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
Shock
directions 1, 2, 3, 4, 5: 100 g (11 ms) at 1 x I
N
direction 6: 100 g (11 ms) at 0.8 x I
N
with curves F1, F2: 100 g (11 ms) at 0.8 x I
N
to IEC 60068-2-27, test Ea
Corrosion 96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
Humidity 240 hours at 95 % RH,
to IEC 60068-2-78, test Cab
Mass approx. 98 g per pole
Standard current ratings and typical internal resistance values
Current
rating (A)
Internal resistance values (Ω) per pole
F1 F2 K1, M1, T1 K2, M2, T2
0,02 1 493 953 2 669 2 457
0,05 276 152 452 376
0,1 58 37 100 94
0,25 8,2 6,0 15,5 14,7
0,5 2,3 1,47 3,9 3,2
0,75 0,98 0,63 1,65 1,56
1 0,58 0,35 0,95 0,90
2 0,145 0,096 0,26 0,20
2,5 0,096 0,061 0,15 0,15
3 0,065 0,048 0,10 0,10
5 0,025 < 0,02 0,042 0,040
6 < 0,02 < 0,02 0,029 0,028
8 < 0,02 < 0,02 < 0,02 < 0,02
10 < 0,02 < 0,02 < 0,02 < 0,02
12 < 0,02 < 0,02 < 0,02 < 0,02
15 < 0,02 < 0,02 < 0,02 < 0,02
16 < 0,02 < 0,02 < 0,02 < 0,02
20 < 0,02 < 0,02 < 0,02 < 0,02
25 < 0,02 < 0,02 < 0,02 < 0,02
30 < 0,02 < 0,02 < 0,02 < 0,02
40 < 0,01 - < 0,01 -
50 < 0,01 - < 0,01 -
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...
www.e-t-a.de
1708
2
1
Ordering information
Type No.
8340 circuit breaker with toggle actuator
Mounting
T rail mounting
Configuration
1 snap-on installation
Number of poles
1 single pole protected
2 two pole protected
3 three pole protected
Panel hardware
0 without panel hardware
Terminal design (main contact)
K1 recessed screw/pressure plates M4
Characteristic curve *
)
Characteristic curve, instantaneous:
F1 DC
F2 AC 50/60 Hz
Short delay:
K1 DC
K2 AC 50/60 Hz
Medium delay:
M1 DC
M2 AC 50/60 Hz
Long delay:
T1 DC
T2 AC 50/60 Hz
Actuator colour / design
A black, long toggle
K black, short toggle
Marking on actuator
0 without marking
L I-O; ON-OFF
M I-O; ON-OFF (I
N
, U
N
, trip curve,
schematic diagram on housing top)
N I-O; ON-OFF (I
N
, on housing top)
Auxiliary contacts
H0 without auxiliary contacts
H1 with auxiliary contact
H2 with auxiliary contact
on one pole only (multipole)
Auxiliary contact function
(see internal connection diagrams)
2 1 N/O contact
3 1 N/C contact
Auxiliary contact terminal design
6 screw/pressure plate M3
Current ratings
0.02...50 A
8340 - T 1 1 0 - K1 M1 - A L H1 2 6 - 10 A
ordering example
}
magnetic,
hydraulic-magnetic
This is a metric design and millimeter dimensions take precedence (
mm
)
inch
*
)
Other characteristic curves upon request (e.g. pulse delayed, for high
inrush currents or capacitive loads)
Approvals
Authority Standard Rated voltage Current ratings
VDE IEC / EN
60934
AC 240/415 V
AC 240 V
DC 80 V
0.02 A…30 A
0.02 A…30 A
0.02 A…50 A
UL UL 1077
AC 250 V
DC 80 V
DC 80 V
0.02 A…30 A
0.02 A…50 A
100 A (2 poles in
parallel)
UL UL 489A
DC 80 V 0.05 A…30 A
(1 + 2 pole)
CSA C22.2 No
235
AC 250 V
DC 80 V
0.02 A…30 A
0.02 A…30 A
CQC GB 17701
AC 240/415 V
AC 240 V
DC 80 V
0.02 A…30 A
0.02 A…30 A
0.02 A…50 A
QPL
Sweden
Defence
Material
Admin.
MIL-C-55629
AC 240 V
DC 50 V
AC 240 V
AC 240 / 415 V
1 A…30 A (8340-F410)
1 A…30 A (8340-410)
1 A…30 A (8340-F420)
1 A…30 A (8340-F430)
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...
www.e-t-a.de
1708 3
1
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...
Dimensions
4.5
OFF
ON
1
LINE
2
LOAD
short toggle
57
43.4
24.4
10-12
9-11
3-pole
2-pole
1-pole
19
38
57
long toggle
30°
89
OFFON
30°
slot for fitting
labels from
Phoenix
45
41.7
19.7
1
LINE
2
LOAD
.776
1.64
1.77
3.50
70.6
2.78
auxiliary contact terminal M3
tightening torque max. 0.5 Nm
wire section max. 2.5 mm
2
(AWG 14)
main contact terminal M4
tightening torque 1.2 Nm
wire section max.:
0.75…10 mm
2
rigid conductor
(AWG 18…AWG 8)
0.75...6 mm
2
flexible conductor
(AWG 18…AWG10)
2.24
1.71
.961
.748
1.50
2.24
Snap-in socket for:
top-hat rail EN 50022-35x7.5
EN 50022-35x15/1.5
.354-.433
.394-.472
.177
Internal connection diagrams
unit II
unit I
I
>
Si
SiSi
Si
2 load
line 1
I
>
Si
SiSi
Si
2 load
. . .
unit IV
. . .
Si
N/C
H136
Si
N/O
H126
line 1
I
>
Si
Si
Si
Siline 1
2 load
Optional N/C or N/O auxiliary
contact (Si)
1-pole
protected magnetically
multipole
1-pole protected
hydraulic-magnetically
SiSi
line 1
2 load
I
>
unit III
or
or
or
or
Installation drawing
min. 18
.709
1
LINE
2
LOAD
min. 1
min .039
mounting area
operating area
(reinforced insulation)
blow out
outlet CBE
terminal area
blow out area
(can be reduced
on request)
Shock directions
Si
AUX
Si
AUX
12
4
3
5
6

8340-T120-K1T1-ALH126-30A

Mfr. #:
Manufacturer:
E-T-A Circuit Breakers
Description:
Circuit Breakers 1077, 2p, DIN, 80VDC Long Delay, N/O Aux, 30A
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union