IELR1-1-63-2.50-91-V

Introduction | 153
Single Pole | 154
Specifications | 155
Operating Characteristics | 156
Delay Curves | 157
Approvals & Decision Tables | 161
IELR Rail-Mount Series
Magnetic Circuit Protectors
IELR Rail-Mount
http://airpax.sensata.com/
IELR Series - Single Pole 154
http://airpax.sensata.com/
IELR Series - Introduction
153
IELR Rail-Mount
.142 [3.6] DEEP (TYP.)
2 X 6-32 THREAD
M3 X 0.5-6H THREAD OPTIONAL
.183
[4.65]
1.437
[36.50]
2.059
[52.30]
DIM.ìAî
1.240
[31.50]
1.417
[35.99]
.689
[17.50]
1.680
[42.67]
1.122
[28.50]
.689
[17.50]
2.500
[63.50]
.138
[3.51]
1.929
[49.00]
.236
[5.99]
3.622
[92.00]
MOUNTING CLIP
ON
OFF O
I
M5 SCREW
Single Pole
.142 [3.6] DEEP (TYP.)
4 X 6-32 THREAD
M3 X 0.5-6H THREAD OPTIONAL
.748
[19.00]
.183
[4.65]
1.437
[36.50]
2.059
[52.30]
DIM.ìAî
1.240
[31.50]
1.417
[35.99]
.689
[17.50]
1.680
[42.67]
1.122
[28.50]
.689
[17.50]
2.500
[63.50]
.138
[3.51]
1.929
[49.00]
.236
[5.99]
3.622
[92.00]
USE TWO MOUNTING CLIPS
ALL MULTI-POLE CONFIGURATIONS
ON
OFF O OFF O
IION
Two Pole
Note: Tolerance ± .015 [.38] unless noted.
Dimensions in brackets [ ] are millimeters.
IELR Series
Hydraulic Magnetic Circuit Protectors
INTRODUCTION
Designed specifically for the 35mm symmetrical DIN rail, Airpax
IALHR, IULHR and IELHR series Rail-Mount Magnetic circuit
protectors offer the advantages of quick and easy mounting or
removal which results in efficient and economical wiring, while
conserving space.
These circuit protectors are available in 1, 2, 3 and 4 pole
models, with a choice of handle colors with on/off and
international I/O markings. These protectors comply with
UL and CSA standards and meet IEC and VDE spacing
requirements. Typical applications include computers and
peripherals, telecommunications, medical equipment, machine
tools and process control instrumentation. They provide
the reliable performance associated with magnetic circuit
protection.
Mounting - These circuit protectors are designed to mount
on standard 35mm DIN rails, such as 35x7.5 or 35x15 per DIN
EN50022. Other specialty rails are available from suppliers that
provide a means of mounting non DIN mount components by
means of special captive jam nuts.
MULTI-POLE DIMENSIONS - DIM “A”
1 pole .750 ± .02 [19.05 ± .5] max
2 pole 1.515 [38.48] max
3 pole 2.265 [57.53] max
4 pole 3.015 [76.58] max
Note: Dimension “A” varies with # of poles
http://airpax.sensata.com/
IELR Series - Operating Characteristics 156
http://airpax.sensata.com/
IELR Series - Specifications
155
IELR Rail-Mount
Series Trip
The most popular configuration for magnetic protectors is the
series trip where the sensing coil and contacts are in series with
the load being protected. The handle position conveniently
indicates circuit status. In addition to providing conventional
overcurrent protection, it’s simultaneously used as an on-off
switch.
Switch Only
In the event that over-current protection is not desired, the coil
mechanism can be deleted, providing an excellent low cost,
single or multi-pole power switch.
Insulation Resistance
100 megohm minimum at 500Vdc between all electrically isolated
terminals.
Dielectric Strength
3750Vac (3750V~) shall withstand AC voltages 50/60Hz for 60
seconds between all electrically isolated terminals.
Endurance
Circuit breakers shall operate a minimum of 10,000 operations;
6,000 with rated current and voltage and 4,000 with no load.
Operating Temperature
–40°C to +85°C.
IEC 144 Classification
Type handle spacings–IP40. Terminals–IP00.
Moisture Resistance
10 days, 95 percent relative humidity at 40°C in accordance with
IEC68-2-3, test C.
Salt Spray
Five percent solution at 35°C in accordance with IEC68-2-11, test
K, 48 hours.
Shock
50g, 11m sec, half sine with rated current, except no current with
handle down. Instantaneous units use 80 percent rated current.
Test in accordance with IEC68-2-27, test E
a
. This assumes that
adequate end stops are used to prevent longitudinal movement
of the circuit protector.
Vibration
4g, 5–500Hz (maximum double amplitude displacement 1.5mm)
with rated current except no current with handle down.
Instantaneous units use 80 percent rated current, in accordance
with IEC68-2-6, test F, method A, one hour per plane. This
assumes that adequate end stops will be used to prevent
longitudinal movement of the circuit protector.
LINE
LOAD
t=f (I)
Three Pole Schematic Diagram
Series
Switch Only
IELR SPECIFICATIONS IELR OPERATING CHARACTERISTICS
Inrush Pulse Tolerance
Pulse tolerance is defined as a single pulse of half sine
wave 50/60Hz peak current amplitude of 8 milliseconds
duration that will not trip the circuit breaker.
PULSE TOLERANCES
Delay Pulse Tolerance
61, 62, 63 (.1 to 70 amps) 12 times (approx.) rated current
61F, 62F, 63F (.1 to 25 amps) 20 times (approx.) rated current
61F, 62F, 63F (25.1 to 70 amps) 18 times (approx.) rated current
PERCENTAGE OF RATED CURRENT VS TRIP TIME IN SECONDS AT +25°C
Delay 100% 125% (Note A) 150% 200% 400% 600% 800% 1000%
41 No Trip May trip .5 to 8 .15 to 1.9 .02 to 4 .006 to .25 .004 to .1 .004 to .05
42 No Trip May trip 5 to 70 2.2 to 25 .40 to 5 .012 to 2 .006 to .2 .006 to .15
43 No Trip May trip 35 to 350 12 to 120 1.5 to 20 .012 to 2.2 .01 to .22 .01 to .1
49 No Trip May trip .100 max. .050 max. .020 max. .020 max. .020 max. .020 max.
51 No Trip .5 to 6.5 .3 to 3 .1 to 1.2 .031 to .5 .011 to .25 .004 to .1 .004 to .08
52 No Trip 2 to 60 1.8 to 30 1 to 10 .15 to 2 .04 to 1 .008 to .5 .006 to .1
53 No Trip 80 to 700 40 to 400 15 to 150 2 to 20 .23 to 9 .018 to .55 .012 to .2
59 No Trip .120 max. .100 max. .050 max. .022 max. .017 max. .017 max. .017 max.
61 No Trip .7 to 12 .35 to 7 .130 to 3 .030 to 1 .015 to .3 .01 to .15 .008 to .1
62 No Trip 10 to 120 6 to 60 2 to 20 .2 to 3 .02 to 2 .015 to .8 .01 to .25
63 No Trip 50 to 700 30 to 400 10 to 150 1.5 to 20 .4 to 10 .013 to .85 .013 to .5
69 No Trip .120 max. .100 max. .050 max. .022 max. .017 max. .017 max. .017 max.
71 No Trip .44 to 10 .3 to 7 .1 to 3 .03 to 1 .012 to .3 .004 to .15 .004 to .1
72 No Trip 1.8 to 100 1.7 to 60 1 to 20 .15 to 3 .04 to 2 .008 to .79 .006 to .28
73 No Trip 50 to 600 30 to 400 10 to 150 1.8 to 20 .22 to 10 .18 to .88 .011 to .5
79 No Trip .120 max. .100 max. .050 max. .023 max. .016 max. .015 max. .015 max.
Notes: All trip times and trip currents are specified with the protector mounted in the normal vertical position at ambient temperature of 25 C.
Protectors do not carry current prior to application of overload.
A: 135% for delays 71, 72, 73 and 79.
APL/UPL - NOMINAL DCR / IMPEDANCE
Current
Ratings
(Amps)
Resistance (ohms) Impedance (ohms) Impedance (ohms)
DC Delays AC, 50/60Hz Delays AC, 400Hz Delays
51, 52, 53, 59 61, 62, 63, 69 41, 42, 43, 49
0.20
45.8
28.5 71.94
1.0
1.38
1.10 2.85
5.0
.371
.29 .76
10.0
.055
.051 .12
15.0
.017
.016 .032
20.0
.006
.006 .010
30.0
.003
.004 .006
50.0
.0019
.0018 .0019
60.0
.00157
.00134
70.0
.00147
.00133
Notes: DCR and impedance based on 100% rated current applied and
stabilized for a minimum of one hour. Tolerance .05-2.5 amperes ± 20%; 2.6-20
amperes ± 25%; 21-70 amperes ± 50%. Consult factory for special values and
for coil impedance of delays not shown.

IELR1-1-63-2.50-91-V

Mfr. #:
Manufacturer:
Description:
Circuit Breakers
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union