IR601/1

© SGX Sensortech 2016 Document subject to disclaimer on page 1 DS-0239, Issue 1, 13-May-2016, Page 4
SGX Europe Sp. Z o.o.
Building 11
Ligocka St. 103,
40-568 Katowice,
Poland
E: sales.is@sgxsensortech.com
www.sgxsensortech.com
CERTIFICATION
ATEX CSA
Certificate / File:
BAS 01ATEX2110X 2589678
Standards:
EN 60079-0:2012
IEC 60079-1:2014 Ed.7
CSA C22.2 No.30 (M1986)
CSA C22.2 No.142 (M1987)
FM 3600 (Nov 1998)
FM 3615 (Feb 2006)
Product Marking:
II 2G Ex db IIC T5 Gb
Class I
Groups B,C&D
Certified
Manufacturing
Locations:
SGX Europe Sp. z o.o., Ligocka St. 103, 40-568 Katowice, Poland
Certificate
Address:
SGX Europe Sp. z o.o., Ligocka St. 103, 40-568 Katowice, Poland
INSTRUCTIONS SPECIFIC TO HAZARDOUS AREA INSTALLATIONS
(Ref : EU ATEX Directive 2014/34/EU)
1. The head is classified as flameproof equipment and is marked:
BAS01ATEX2110X
II 2G Ex db IIC T5 Gb
T
amb
= -20°C to +60°C
2W/5V MAX
The head should only be used within the limits imposed by this certification and by these conditions of use.
2. The head may be used in a hazardous area without further mechanical protection. However, the cable requires mechanical
protection and must be terminated in a suitable enclosure.
3. The head must be efficiently earthed (grounded). This may be achieved by mounting it into an appropriate earthed metal
junction box or into a non-metallic junction box fitted with an earth continuity plate used in accordance with the box
manufacturer's instructions. There are no internal connections to the sensing head body.
4. In the event that the head becomes embedded in a junction box by over-tightening or corrosion, it may be released by the
use of a spanner or wrench on the two flat surfaces on the sides of the body.
5. There are no user serviceable parts inside the body of the sensing head, and no attempt should be made to open the body
for any purpose. The unit is non-repairable.
6. The head has not been assessed as a safety device (EHSR 1.5).
7. When installed in outdoor locations where rain or spray could interfere with the safe working of the head, or in indoor
locations where water jets, sprays, or hoses are used routinely for cleaning purposes, the head should be fitted with the
Weather Cap that is available as an accessory.
8. The end-user/installer should be aware that the certification of the head relies in its construction on the use of the following
materials, which are suitable for most common applications:
Enclosure ........... Stainless Steel
Sinter ................. Stainless Steel
Bushing .............. Epoxy resin
In accordance with the Note in EN60079-0:2006 Clause 6.1, the end-user/installer shall inform the manufacturer of any
adverse conditions that the head may encounter. This is to ensure that the head is not subject to conditions that may cause
degradation of these materials.
© SGX Sensortech 2016 Document subject to disclaimer on page 1 DS-0239, Issue 1, 13-May-2016, Page 5
SGX Europe Sp. Z o.o.
Building 11
Ligocka St. 103,
40-568 Katowice,
Poland
E: sales.is@sgxsensortech.com
www.sgxsensortech.com
OUTLINE (All dimensions in millimetres; dimensions without limits are nominal)
Table 1 - Connections
HE14 crimp socket, 8-way double-row, single orientation
Socket
Wire Colour
Description
1
Red
Temperature Output
2
Yellow
Active Detector Output
3
Blue
0 VA
4
Black
5 VA
5
Orange
2.5 V Reference
6
Brown
Reference Detector Output
7
Green
Lamp
8
Purple
Lamp
Table 2 - Mounting Options
The sensing head is supplied with one of three different mounting threads at the user's choice.
Thread
Thread
code
Dimension X
(mm)
Metric 20 x 1.5 mm
1
16.00
ANP (Taper) ½" - 14 NPT
2
19.85
ANP (Taper) ¾" - 14 NPT
3
20.16
Taper threads are manufactured in accordance with ANSI/ASME B1.20.1.
© SGX Sensortech 2016 Document subject to disclaimer on page 1 DS-0239, Issue 1, 13-May-2016, Page 6
SGX Europe Sp. Z o.o.
Building 11
Ligocka St. 103,
40-568 Katowice,
Poland
E: sales.is@sgxsensortech.com
www.sgxsensortech.com
ACCESSORIES
(All dimensions in millimetres)
Three accessories are available to complement the IR600
Series gas detection head.
Flow Cap DAS546633AA
The Flow Cap allows the IR600 to be used in applications
where it is to be aspirated permanently with a pumped or
pressurised sample. The cap is made of 316 stainless steel
and can be used in a variety of applications involving
pumped sampling analysis or detection systems.
Weather Cap DAS546632AA
The Weather Cap protects the IR600 from water when
used in external locations, where rain or spray could
interfere with the safe working of the head, or in internal
locations where water jets, sprays or hoses are used
routinely for cleaning purposes, etc. The cap is made of
316 stainless steel and has been tested to IP64 for
effectiveness, and also to ensure that it does not
significantly affect the IR600's performance.
Quick Calibration Hood DPP546618DA
The Quick Calibration Hood is constructed from
polypropylene, and provides a convenient means of
supplying test gases to the IR600 in the field, for calibration
and checking purposes. The assembly push-fits into the
central gas access recess of the head, and is designed to
accommodate 6 mm ID or ¼" flexible tubing.
ORDERING INFORMATION
IR60n/n
TARGET GAS
1 Carbon Dioxide
2 Hydrocarbons (Narrow band)
3 Hydrocarbons (Broad band)
4 Acetylene
THREAD TYPE
(Refer to Table 2, page 5)
1 Metric 20 x 1.5 mm
2 ANP (Taper) ½" - 14 NPT
3 ANP (Taper) ¾" - 14 NPT

IR601/1

Mfr. #:
Manufacturer:
Amphenol SGX Sensortech
Description:
Air Quality Sensors IR Sens Hdfor0-5%CO2 M20 Thrd in AmpCirc
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: