IR604/3

___________________________________________________________________________________________
Whilst SGX has taken care to ensure the accuracy of the information contained herein it accepts no responsibility for the consequences of any use thereof and also
reserves the right to change the specification of goods without notice. SGX accepts no liability beyond the set out in its standard conditions of sale in respect of
infringement of third party patents arising from the use of SGX products in accordance with information contained herein.
In case of modification of the product, SGX disclaims all liability.
SGX Europe sp .z o.o. Poland REGON: 362332227 DS-0239, Issue 1, 13-May-2016, Page 1
SGX Europe Sp. z o.o.
Building 11
Ligocka St. 103,
40-568 Katowice,
Poland
T: +48 (0) 32 438 4778
E: sales.is@sgxsensortech.com
www.sgxsensortech.com
IR600 Datasheet
Infrared Gas Sensor for Hazardous Areas
(Fixed Systems)
The IR600 Series gas sensors are designed to detect and
monitor the presence of CO
2
, hydrocarbons and acetylene
using the same non-dispersive infrared (NDIR) principle as
used in the SGX Sensortech range of miniature infrared gas
sensors. Dual detector channels are used with a reference for
background compensation. A temperature sensor is mounted
for temperature compensation.
IR600 sensors are designed to be integrated with fixed gas
detection systems. Their construction is a stainless steel
flameproof enclosure with an integral stainless steel sinter for
the safe entry of the gases being tested.
Three types of mounting thread are available to allow easy
fixing to the junction box of the fixed system. On the front face
there is an external M46 thread for attaching optional
accessories for use in different applications. The IR600 Series
incorporates an inbuilt and sealed preamplifier/buffer and
require connection to suitable transmitter systems for their
power supply, operation and signal processing. The IR600
lead in/out terminates in an 8-pin connector.
FEATURES
For detection of the following gases:
o Carbon Dioxide (IR601),
o Hydrocarbons (IR602, IR603)
o Acetylene (IR604)
Diffused gas sampling via sinter
Low power
Reference channel for self-compensation
Special gold plated optical/gas cavity for stable signal
levels
Operational in varying temperature, pressure and
humidity
Fast response
Rugged stainless steel construction
No moving parts
Resistance to corrosion
Immunity from ‘poisoning’
Reliable fail-safe operation
Low maintenance
Sealed preamplifier/buffer electronics
Accessories available for field applications
ATEX certified
CSA certified (Canada and US)
OPERATING PRINCIPLE
SGX Sensortech manufactures a range of Infrared (IR) Gas
Sensors for a variety of gases and vapours in different
applications. These are compact and robust gas diffusion type
sensors based on an SGX Sensortech patented optical
design. They run on low power and use well proven Non-
Dispersive Infrared (NDIR) detection methods.
The sensor operates using the natural ability of the target
gases to absorb radiation in the infrared portion of the
electromagnetic spectrum. Using an infrared source, detector
and selective optical filters the SGX infrared sensors can be
used to detect a range of target gases. More information on
the NDIR sensors can be found in the SGX Sensortech
Application Notes.
TECHNICAL SPECIFICATION
Mechanical
Dimensions
See Outline on Page 5
Body material
Stainless Steel
Weight
435g
Environmental
Ambient temperature range
for operation (ATEX):
for operation (CSA):
storage:
-20°C to +60°C
-20°C to +65°C
-20°C to +60°C
Operational pressure range
700kPa to 1300kPa
Humidity range for operation
and storage
0 to 95% RH
(Non-condensing)
Gases Detected
Carbon Dioxide,
hydrocarbons
Electrical
DC supply to detectors
See Outline on Page 5
Typical power
180mW / 5V
Lamp Supply
(Recommended)
+5V, 60mA
(Square Wave at 4Hz, 50% duty cycle)
© SGX Sensortech 2016 Document subject to disclaimer on page 1 DS-0239, Issue 1, 13-May-2016, Page 2
SGX Europe Sp. Z o.o.
Building 11
Ligocka St. 103,
40-568 Katowice,
Poland
E: sales.is@sgxsensortech.com
www.sgxsensortech.com
PERFORMANCE
For test purposes, all data taken using the following conditions:
- SGX linearisation and temperature compensation algorithms; see Infrared Sensor Application Notes.
- Lamp modulation 0.4 - 5.0 V, square wave, at 4 Hz and 50% duty cycle.
- Ambient temperature (20°C) and pressure (103 kPa).
- All gases diluted in dry nitrogen.
Sensor type IR601 IR602 IR603 IR604
Gas Carbon Dioxide Hydrocarbons Acetylene
Sensing range 0 - 5.0%vol.
0 - 100% LEL and 0 - 100% vol.
(same sensor is suitable for both ranges)
Maximum response time (T90) <40 s
Voltage output in nitrogen for active and
reference channels
4.0 ± 0.5 V centred on 2.5 V
Sensitivity to gas over full concentration range
(before linearisation)
see Fractional Absorbance curves
Maximum deviation from linearity
±0.1% vol.
Maximum variation of zero from
20 to +55
°
C ±10 ppm/°C ±30 ppm/°C
Resolution (See note 1)
100 ppm
(at 2%vol)
500 ppm
(at 5%vol)
Maximum non-reproducibility of zero at 20
°
C ±100 ppm ±500 ppm
Maximum non-reproducibility of sensitivity at 20
°
C ±200 ppm <±1000 ppm
Long-term zero drift/month
<±100 ppm ±500 ppm
Response to 0 - 90% change in RH at 20 °C
(in target gas)
0% vol
(at 2%vol)
+0.1% vol
(at 5%vol)
+0.3% vol
(at 5%vol)
+0.5% vol
(at 2.5%vol)
MTBF (lamp dependent only) >10 years for 5 V operation
Vibration Complies with EN 60079-29-1
Ingress Protection See Weather Cap accessory, Page 6
Note 1: The resolution will vary with gas concentration due to the non-linear response to the target gas, therefore the best resolution will be at the low
concentrations and will get worse as the concentration increases.
HANDLING PRECAUTIONS
1. Do not allow sensors to fall on the floor. This could cause lamp filament breakage, damage to the pins and the gas entrance
aperture.
2. Do not apply mechanical force against the gas entrance aperture.
3. Do not immerse sensors in water or other fluids.
4. Protect the gas entrance aperture against dust ingress and sprayed materials.
5. Anti-static handling precautions must be taken.
© SGX Sensortech 2016 Document subject to disclaimer on page 1 DS-0239, Issue 1, 13-May-2016, Page 3
SGX Europe Sp. Z o.o.
Building 11
Ligocka St. 103,
40-568 Katowice,
Poland
E: sales.is@sgxsensortech.com
www.sgxsensortech.com
FRACTIONAL ABSORBANCE CURVES
These show the typical sensitivity versus concentration before linearisation for the range of gases. For further explanation, refer
to the Infrared Sensor Application Notes.
Principle Target Gases
IR601
(0-2% Carbon
Dioxide)
IR602
(0-100% LEL
Methane)
IR603
(0-100% LEL
Methane)
IR604
(0-2.5% Vol
Acetylene)
Other Target Gases
IR602
&
IR603
(0-25%LEL
Ethylene)
IR60
2
&
IR603
(0-30%LEL
Propane)
IR603
(0-1.5%
Benzene)

IR604/3

Mfr. #:
Manufacturer:
Amphenol SGX Sensortech
Description:
Air Quality Sensors IRSenHd0-100%LELAcet 3/4"Thrd in AmpCirc
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: