CXA20-48D05

2 YEAR WARRANTY
CXA20 Series
Single and dual output
4:1 input voltage range
No minimum load on singles
6 A on 3.3 V output (@ 48 Vin) at 50 ˚C in still air
Wide operating temperature with overtemperature
protection
±10% output voltage trim
Remote On/Off control
Overvoltage protection
Available RoHS complaint
The CXA20 is a new 20 W addition to the CXA family of open-frame, isolated, dc-dc
converters. The five model series features a 4:1 input voltage range of 18 Vdc to
75 Vdc, making it suitable for a wide variety of communications and distributed
power applications. With its 2.0 x 1.6 inch industry standard footprint, the CXA20
provides an easy upgrade option for new and existing Artesyn customers seeking a
high-performance, cost-effective power supply. The CXA20 is available in output
voltages of 3.3 V, 5 V, 12 V, ±5 V and ±12 V. The 3.3 V version delivering up to 6 A is
fully rated to 20 W. Typical efficiency for the CXA20 is 83%. The CXA20 offers remote
ON/OFF as well as overvoltage, overtemperature and short circuit protection
features.
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
EMC CHARACTERISTICS
ETS 300 386-1 table 5
Conducted emissions EN55022, ext. cap. (Note 5) Level A
EN55022, external filter, Level B
VDE0878, 48V models
Radiated emissions EN55022-B See App. Note 107
Immunity:
ESD air EN61000-4-2 8 kV (NP), 15 kV (RP)
ESD contact EN61000-4-2 6 kV (NP), 8 kV (RP)
EFT DC power EN61000-4-4 2 kV (NP), 4 kV (LFS)
EFT signal EN61000-4-4 1 kV (NP), 2 kV (LFS)
Radiated field enclosure EN61000-4-3 10 V/m (NP)
Surges indoor signal EN61000-4-5 500 V (RP)
Conducted (dc power) EN61000-4-6 10 V (NP)
Conducted (signal) EN61000-4-6 10 V (NP)
Input transients ETS 300 132-2, ETR 283
GENERAL SPECIFICATIONS
Efficiency See table
Overtemp. shutdown 120 ˚C
Isolation voltage Input/output test voltage 1500 Vdc
Switching frequency Fixed 400 kHz
Approvals and standards
EN60950
(See Notes 6,7,8) UL1950 File No. E136005
Material flammability UL94V-0
Weight 26 g (0.92 oz)
MTBF MIL-HDBK-217F 3,485,000 hours
(Representative model Parts stress method
48S05J @ 48 Vin) Ground Benign @ 25 °C
ENVIRONMENTAL SPECIFICATIONS
Thermal performance Operating ambient -40 °C to +60 °C,
temperature (See Note 9)
Non-operating -55 °C to +125 °C
ETS 300 019-2-3 Classes T3.1, 3.2, 3.3, 3.5
Air temperature Low: IEC 68-2-1 -40 °C
High: IEC 68-2-2 +60 °C
Change: IEC 68-2-14 -40 °C to +60 °C
Relative humidity IEC 68-2-56 10% to 100% RH
IEC 68-2-30 Condensation
OUTPUT SPECIFICATIONS
Voltage accuracy ±1.0%
Line regulation Singles/dual positives ±0.1%
(LL to HL) Dual negatives ±0.1%
Load regulation Full load to minimum load
(not incl. cross reg.) S3V3 ±0.2%
Singles/dual positives ±0.1%
Dual negatives ±0.1%
Minimum load Singles None
Duals (for imbalanced loads) 10%
Ripple and noise S3V3, S05, D05 75 mV pk-pk max.
20 MHz bandwidth S12, D12 100 mV pk-pk max.
All models 20 mV rms max.
Temperature coefficient ±0.02%/°C
Overvoltage protection See Application Note 107
Short circuit protection Hiccup Continuous
Short <20 m automatic recovery
Transient response 25% load step ±2.0% max. dev.,
300 µs recovery to
within total error band
Load cross regulation 10% load to full load, ±7.0%
(See Note 1) either output
INPUT SPECIFICATIONS
Input voltage range 48 Vin nominal 18-75 Vdc
Input fuse HRC recommended 2.0 A
Max. input rise 48 V ETS300-132 5 V/ms
and fall time
UVLO turn ON voltage (See Note 4) 92%
UVLO turn OFF voltage (See Note 4) 86%
Remote ON/OFF
Logic compatibility CMOS/TTL/Open Collector
ON Open circuit or >2 Vdc
OFF <1.2 Vdc
SPECIFICATIONS
File Name: cxa20.pdf Rev (02): 09 Dec 2005
NNootteess
1 Negative output voltage deviation when either load is changed.
2 For TVS/Zener specifications please see Application Note 107.
3 On dual output models, OVP protection is on positive outputs only.
4 With respect to minimum input voltage.
5 With one external 4 µF capacitor across the input.
6 Unit provides basic insulation up to the 75 Vdc maximum input voltage.
7 Maximum continuous output power not to exceed 20 Watts.
8 User must provide 2 A HRC (recommended) in line fuse in order to comply
with safety approvals.
9 Download Application Note 107 and the full data sheet from our website.
10 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on
special request, please contact your local sales representative for details.
11 NOTICE: Some models do not support all options. Please contact your
local Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
CXA20 Series
Single and dual output
File Name: cxa20.pdf Rev (02): 09 Dec 2005
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
INPUT OUTPUT OVERVOLTAGE OUTPUT TYPICAL MODEL
VOLTAGE VOLTAGE PROTECTION
(2,3)
CURRENT (MAX.) EFFICIENCY NUMBER
(10,11)
18-75 Vdc 3.3 V 3.7 V 6 A 80% CXA20-48S3V3J
18-75 Vdc 5 V 6.67 V 4 A 83% CXA20-48S05J
18-75 Vdc 12 V 14.25 V 1.66 A 83% CXA20-48S12J
18-75 Vdc ±5 V 6.67 V 2 A ea. 84% CXA20-48D05J
18-75 Vdc ±12 V 14.25 V 0.83 A ea. 84% CXA20-48D12J
PIN CONNECTIONS
PIN NUMBER SINGLE OUTPUT DUAL OUTPUT
1 + Input + Input
2 – Input - Input
3 No Pin No Pin
4 Remote On/Off Remote On/Off
5 No Pin + Output
6 + Output Common
7 - Output - Output
8 Trim Trim
Derating Curve Output Current vs Temperature S3V3J
Natural Convection (<0.1 m/s airflow)
-40˚C
0
20
40
60
80
100
Ambient Temperature
Rated Output Current
-20˚C
20˚ 40˚ 60˚ 80˚ 100˚
75%
MAX. TEMPERATURES FOR FULL RATED OUTPUT CURRENT
MODEL FULL Vin RANGE Vin <60 Vdc
48S3V3J 50 ˚C 50 ˚C
48S05J 55 ˚C 60 ˚C
48S12J 50 ˚C 55 ˚C
48D05J 55 ˚C 60 ˚C
48D12J 50 ˚C 60 ˚C
TRIM
DOWN
+ Output
TRIM
UP
Trim
- Output
EXTERNAL OUTPUT TRIMMING
All models can be externally trimmed by ±10% using either
method shown below. See Application Note 107 for details.
International Safety Standard Approvals
UL/cUL CAN/CSA 22.2 No. 60950-00 : UL 60950
File No. E174104
VDE Certificate No.112836. File No. 10401-3336-0154
CB Report and Certificate to IEC60950, Licence No. 121914
STAND-OFFS
4 PLACES
Ø0.040 ±0.002
(Ø1.02 ±0.05)
2.00 ±0.02
(50.80 ±0.5)
1.80
(45.72)
1
ALL DIMENSIONS IN INCHES (mm)
General tolerance ±0.010 (±0.25)
unless otherwise specified
2
4
5
6
7
8
0.02 ±0.004
(0.50 ±0.1)
1.60 ±0.02
(40.64 ±0.5)
0.70
(17.78)
0.20
(5.08)
0.10
(2.54)
0.30
(7.62)
0.70
(17.78)
0.50
(12.70)
0.60
(15.24)
0.14 ±0.02
(3.60 ±0.5)
0.413
(10.50)
MAX.
OPEN
FRAME
HEIGHT
BOTTOM
VIEW
Datasheet © Artesyn Technologies
®
2005
The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
CXA20 Series
Single and dual output
Please consult our website for the following items: Application Note Longform Data Sheet
www.artesyn.com
File Name: cxa20.pdf Rev (02): 09 Dec 2005

CXA20-48D05

Mfr. #:
Manufacturer:
Artesyn Embedded Technologies
Description:
Isolated DC/DC Converters 20W 5V 2A EA.
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union