MNG10-10FBK

Installation Information
UL Listed and CSA Certified for use on stranded copper
(AWG) wire only.
Strip away the end 3/8 inch of wire insulation.
Make the crimp in the proper station of a recommended
3M crimp tool: TH-440, TH-450 (scissor style), or TR-482,
TR-490 (ratchet style) hand tools.
Scotchlok
Terminals
MNG18-4FB/S thru MNG10-10FB
Block Fork, Nylon Insulated with Insulation Grip
Data Sheet
Barrel Crimp (Electrical)
L
E
C
W
Insulation Crimp (Mechanical)
LISTED 314R
UNDERWRITERS
LABORATORIES
STANDARD NO. UL 486A
3M FILE NO. E23438
CANADIAN STANDARDS
ASSOCIATION
STANDARD NO. C22.2
NO. 0. 65
3M FILE NO. LR22190
tcudorP
rebmuN
eriW
egnaR
)GWA(
dutS
eziSWCLE ssenkcihT
lerraB
htgneL
lerraB
.D.I
mumixaM
noitalusnI
retemaiD
S/BF4-81GNM81-22452.052.048.096.0030.052.0070.0541.0
S/BF6-81GNM81-22652.052.048.096.0030.052..0070.0541.0
BF6-81GNM81-22603.052.048.096.0030.052.0070.0541.0
BF8-81GNM81-22803.052.048.096.0030.052.0070.0541.0
BF01-81GNM81-220103.052.048.096.0030.052.0070.0541.0
S/BF4-41GNM41-61452.052.068.017.0030.052.0090.0071.0
S/BF6-41GNM41-61652.052.068.017.0030.052.0090.0071.0
BF6-41GNM41-61603.052.068.017.0030.052.0090.0071.0
BF8-41GNM41-61803.052.068.017.0030.052.0090.0071.0
BF01-41GNM41-610103.052.068.017.0030.052.0090.0071.0
BF6-01GNM01-21623.092.030.148.0040.052.0531.0052.0
BF8-01GNM01-21823.092.030.148.0040.052.0531.0052.0
BF01-01GNM01-210123.092.030.148.0040.052.0531.0052.0
WARNING
Turn power off before installing or removing terminal. All electrical
work should be done according to appropriate electrical codes.
Specifications
Wire Size: See Table Above
Barrel Seam: Butted with Insulation Grip
Max. Voltage Rating: 600 V Building Wire
1000 V Signs, Fixtures
and Luminaires
Max. Operating Temp.: 221˚F (105˚C)
Max. Current: Same as Wire
Insulator Material: Nylon
Terminal Material: ETP Copper
Insulation Grip Material: Brass
Plating: Tin
Electrical Products Division
6801 River Place Blvd.
Austin, TX 78726-9000
http://www.3M.com/elpd
Litho in USA.
© 3M 2002 78-8126-0493-8-A
IMPORTANT NOTICE
Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability
associated with such use.
Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture as of the date of purchase.
3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be,
at 3M’s option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will
not be liable for any loss or damage arising from this 3M product, whether direct, indirect, special, incidental or consequential
regardless of the legal theory asserted.
3M and Scotchlok are trademarks of 3M
Engineering Specification
Crimp-type terminals shall, electrically and mechanically,
connect to a pre-stripped end of a stranded copper wire:
and have a flat tongue portion with a central opening for
mounting around a screw or stud.
The terminal line shall offer tongue variations in hole
(stud) size (6, 8 10, etc.) and configuration (ring, fork,
block fork, flanged block fork, locking fork, etc.): and
barrel variations in wire (AWG) size (22-18, 16-14, 12-10,
etc.) and construction (non-insulated brazed seam, vinyl
insulated butted seam, nylon insulated with insulation grip,
etc.). The terminal line shall have regulatory agency
coverage (UL Listing, CSA Certification). The terminal
tongue shall be marked with the wire range and
manufacturers symbol (
).
The nylon-insulated, block fork terminal with insulation
grip shall be tin-plated, annealed copper, with the tongue
having a specified stud slot (size 4 thru 10) and a butted
seam barrel with a tin plated brass, funnel entry insulation
grip, covered by a molded nylon sleeve, color coded and
sized for a specified (AWG) wire range (22-18, 16-14,
12-10).
Insulated terminals shall be UL Listed and CSA Certified
for 600 Volts maximum building wire: 1000 Volts
maximum in signs, fixtures and luminaires and have a
maximum operating temperature of 221°F (105°C).

MNG10-10FBK