Technical data and measuring conditions
Rated voltage V
R
250 V AC (50/60 Hz) / 250 V DC
Rated current I
R
Referred to 40 °C rated temperature
Test voltage V
test
1414 V DC, 2 s (line/line)
2700 V DC, 2 s (lines/case)
Climatic category (IEC 60068-1) 25/085/21 (25 °C/+85 °C/21 days damp heat test)
Approvals IEC 60939, UL 1283, CSA C22.2 No.8
Characteristics and ordering codes
I
R
A
C
R
X2
µF
C
R
Y2
pF
L
R
mH
I
LK
mA
Approx.
weight
g
Ordering code
Approvals
× = Approval granted
V
R
= 250 V AC/DC
1 2 × 0.47 2 × 4700 2 × 5.6 0.369 150 B84114D0000A010 × × ×
1 2 × 0.47 2 × 4700 2 × 5.6 0.369 150 B84114D0000B010 × × ×
2 2 × 0.47 2 × 4700 2 × 5.6 0.369 150 B84114D0000A020 × × ×
2 2 × 0.47 2 × 4700 2 × 5.6 0.369 150 B84114D0000B020 × × ×
3 2 × 0.47 2 × 4700 2 × 5.6 0.369 150 B84114D0000A030 × × ×
3 2 × 0.47 2 × 4700 2 × 5.6 0.369 150 B84114D0000B030 × × ×
6 2 × 0.47 2 × 4700 2 × 4.7 0.369 230 B84114D0000A060 × × ×
6 2 × 0.47 2 × 4700 2 × 4.7 0.369 230 B84114D0000B060 × × ×
10 2 × 0.68 2 × 4700 2 × 4.7 0.369 420 B84114D0000A110 × × ×
10 2 × 0.68 2 × 4700 2 × 4.7 0.369 420 B84114D0000B110 × × ×
Cases and dimensions
I
R
Dimensions (mm)
A b
1
b
2
b
3
b
4
l
1
l
2
l
3
l
4
h
1
h
2
1
1
50.8
50.8
31.5
31.5
60.4
70
63.5
63.5
74.7
84.5
89.5
89.5
28.6
28.6
20
20
2
2
50.8
50.8
31.5
31.5
60.4
70
63.5
63.5
74.7
84.5
89.5
89.5
28.6
28.6
20
20
3
3
50.8
50.8
31.5
31.5
60.4
70
63.5
63.5
74.7
84.5
89.5
89.5
28.6
28.6
20
20
6
6
50.8
50.8
31.5
31.5
60.4
70
75.5
75.5
87.1
97
101.5
101.5
31.8
31.8
20
20
10
See dimensional drawing
10
2-line filters B84114D
SIFI-D for high insertion loss
Page 3 of 10Please read Cautions and warnings and
Important notes at the end of this document.