THD< 20% when output loading 70% at 115VAC/230VAC input and output loading 80% at 277VAC input≧≧
TOTAL HARMONIC DISTORTION
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
72 units (circuit breaker of type B) / 80 units (circuit breaker of type C) at 230VAC
SPECIFICATION
MODEL PLD-25-1400PLD-25-1050PLD-25-700PLD-25-350
RATED CURRENT
OPERATING VOLTAGE RANGE
RATED POWER
OUTPUT
SETUP TIME
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
SHORT CIRCUIT
OVER TEMPERATURE
1400mA1050mA700mA350mA
25.2W25.2W25.2W20.3W
2Vp-p2.2Vp-p2.7Vp-p4.6Vp-p
60V 50V 35V 25V
500ms / 230VAC 2000ms / 115VAC at full load
47 ~ 63Hz
PF>0.98/115VAC, PF>0.92/230VAC, PF>0.91/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
84%85%86%85%
0.6A/115VAC 0.3A/230VAC 0.2A/277VAC
COLD START 25A(twidth=75 s measured at 50% Ipeak) at 230VACμ
<0.5mA / 240VAC
Hiccup mode, recovers automatically after fault condition is removed.
-30 ~ +60 (Refer to "Derating Curve")℃
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH℃
±℃ ℃0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
968.6Khrs min. MIL-HDBK-217F (25 )℃
84*57*29.5mm (L*W*H)
0.19Kg; 72pcs/14.7Kg/0.75CUFT
25W Single Output LED Power Supply
■ Features :
PLD-25 series
RIPPLE & NOISE (max.) Note.1
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, re-power on to recover
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH℃
24 ~ 36V40 ~ 58V 12 ~ 18V16 ~ 24V
File Name:PLD-25-SPEC 2018-01-10
1. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
2. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
3. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
connected to the mains.
VOLTAGE RANGE 90 ~ 295VAC 127 ~ 417VDC
NO LOAD OUTPUT VOLTAGE (max.)
±5.0%
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024,EN61547, light industry level, criteria A, EAC TP TC 020
EMC IMMUNITY
EMC EMISSION
Universal AC input / Full range (up to 295VAC)
Built-in active PFC function
Constant current design
Protections: Short circuit / Over temperature
Cooling by free air convection
Fully isolated plastic case
Class 2 Power Unit
ⅡClass power unit, no FG
IP42 design
Suitable for LED related fixture or appliance
(such as LED Decoration or Advertisement devices)
100% full load burn-in test
Low cost
High reliability
Suitable for dry / damp locations
3 years warranty
CURRENT ACCURACY
UL8750, CSA C22.2 No. 250.0-08(except for PLD-25-350, PLD-25-700), ENEC EN 61347-1, EN 61347-2-13 independent,
EN 62384, IP42 approved ;EAC TP TC 004, design refer to UL60950-1, TUV EN60950-1
Compliance to EN55015, EN61000-3-2 Class C ( 75% load) ; EN61000-3-3, FCC part 18 non-consumer equipment, EAC TP TC 020≦
SELV
110
IP42
(except for 350mA&700mA)
( for 350mA&700mA)