RS
Input Voltage Range 2:1 and 4:1
Output Accuracy ±2% typ.
Line Voltage Regulation ±0.5% max.
Load Voltage Regulation 20%-100% Load ±0.5% max.
Minimum Load 10%
(2)
Output Ripple and Noise (20MHz limited) 50mVp-p max.
Switching Frequency Full Load 100kHz min. / 300kHz max.
Efficiency at Full Load See Selection Guide
Quiescent Current RS-05xxS_D 40mA typ.
Nominal input Voltage RS-12xxS_D 32mA typ.
(Standard, /H2 and /H3) RS-24xxS_D, SZ_DZ 25mA typ.
RS-48xxS_D, SZ_DZ 15mA typ.
Isolation Voltage Standard (tested for 1 second) 1000VDC
(rated for 1 minute**) 500VAC / 60Hz
/H2 Version (tested for 1 second) 2000VDC
(rated for 1 minute**) 1000VAC / 60Hz
/H3 Version (tested for 1 second) 3000VDC
(rated for 1 minute**) 1500VAC / 60Hz
Isolation Capacitance Standard 2:1 Single 10pF min. / 40pF typ. / 60pF max.
/H2 and /H3 2:1 Single 5pF min. / 30pF typ. / 60pF max.
Standard 2:1 Dual 120pF min. / 170pF typ. / 250pF max.
/H2 and /H3 2:1 Dual 5pF min. / 30pF typ. / 60pF max.
Standard 4:1 Single/Dual 200pF max.
/H2 and /H3 4:1 Single/Dual 30pF max
Isolation Resistance 1GΩ min.
Short Circuit Protection Continuous
Operating Temperature Range 2:1 –40°C to +85°C
(No Derating) 4:1 –40°C to +75°C
Storage Temperature Range –55°C to +125°C
Relative Humidity 95% RH
Package Weight 4.7g
Packing Quantity 22 pcs per Tube
MTBF (+25°C) using MIL-HDBK 217F 1398 x 10
3
hours
(+85°C) using MIL-HDBK 217F 210 x 10
3
hours
Certifications
EN General Safety Report: SPCLVD1605077-10 EN60950-1, AM2:2013
EN Medical Safety Report: MDD1205098-3 + RM1205098-3 IEC/EN 60601-1 3rd Edition
Medical Report + ISO14971 Risk Assessment
UL General Safety Report: E224736-A35 UL60950-1, 2nd Edition 2014
CSA C22.2 60950-1-07, 2nd Edition 2014
Specifications (measured at T
A
= 25°C, nominal input voltage, full load and after warm-up time unless otherwise specified)
RS-S_D(Z)
Series
ECONOLINE
DC/DC-Converter
}
Detailed Information see
Application Notes chapter "MTBF"
**Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer to our Application Notes.
Notes
Note 1: Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter
Note 2: The RS series requires a minimum of 10% load on the output to maintain specified regulation. Operating under no-load conditions
will not damage these devices; however, they may not meet all listed specifications.
REV: 1/2017 E-127www.recom-power.com