PCS2P2309NZ
Operating Conditions
Parameter Description Min Max Unit
V
DD
Supply Voltage 3.0 3.6 V
T
A
Operating Temperature -40 85 °C
C
L
Load Capacitance, Fout < 100MHz 30 pF
Load Capacitance,100MHz < Fout < 133.33MHz 15 pF
C
IN
Input Capacitance 7 pF
BUF_IN,
OUTPUT
[1:9]
Operating Frequency DC 133.33 MHz
t
PU
Power-up time for all V
DD
’s to reach minimum specified voltage (power
ramps must be monotonic)
0.05 50 mS
Electrical Characteristics
Symbol Parameter
Test Conditions Min Max Unit
V
IL
Input LOW Voltage
1
0.8 V
V
IH
Input HIGH Voltage
1
2.2 V
I
IL
Input LOW Current V
IN
= 0V 50.0 µA
I
IH
Input HIGH Current V
IN
= V
DD
100.0 µA
V
OL
Output LOW Voltage
2
I
OL
= 12mA 0.4 V
V
OH
Output HIGH Voltage
2
I
OH
= -12mA 2.4 V
I
DD
Supply
Current
0°C to +70°C
Unloaded outputs at 66.66MHz
30
mA
-40°C to +85°C 32
Notes: 1. BUF_IN input has a threshold voltage of V
DD
/2.
2. Parameter is guaranteed by design and characterization. It is not 100% tested in production.
Switching Characteristics
1
Symbol Parameter
Test Conditions
Min Typ Max Unit
t
3
Rise Time
2
Measured between 0.8V and 2.0V 1.5 2 nS
t
4
Fall Time
2
Measured between 2.0V and 0.8V
1.5 2 nS
t
D
Duty Cycle
2
= t
2
÷ t
1
Measured at 1.4V (For an Input
Clock Duty Cycle 50%)
45 50 55 %
t
5
Output to Output Skew
2
All outputs equally loaded ±250 pS
t
6
Propagation Delay,
BUF_IN Rising Edge to
OUTPUT Rising Edge
2
Measured at V
DD
/2 4 6 nS
Note: 1. All parameters specified with loaded outputs.
2. Parameter is guaranteed by design and characterization. It is not 100% tested in production.