HL2-H-DC6V

HL
SPECIFICATIONS
15A (1C), 10 A (2C)
SPACE SAVING
POWER RELAY
HL RELAYS
mm inch
27.2
1.071
35.4
1.394
20.8
.819
FEATURES
• High switching capacity in a compact size
1 Form C (15 A 125 V AC), 2 Form C (10 A 250 V AC)
• Rugged construction for tough applications
• Long life
Mechanical: Min. 10
8
operations (DC),
Min. 5 × 10
7
operations (AC)
Electrical: Min. 5 × 10
5
operations
Contacts
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load.
Remarks
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as “Initial breakdown voltage” section
*
2
Detection current: 10 mA
*
3
Excluding contact bounce time
*
4
Half-wave pulse of sine wave: 11ms; detection time: 10µs
*
5
Half-wave pulse of sine wave: 6ms
*
6
Detection time: 10µs
*
7
Refer to 6. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT
Characteristics (at 25°C 77°F, 50% Relative humidity)
Arrangement 1 Form C 2 Form C
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
50 m
Contact material Silver alloy
Rating
(resistive)
Nominal switching
capacity
15 A 125 V AC,
10 A 250 V AC
10 A 250 V AC
Max. switching power
AC: 2,500 VA
DC: 90 W
AC: 2,500 VA
DC: 90 W
Max. switching voltage
250 V AC
30 V DC
250 V AC
30 V DC
Max. switching current 15 A 10 A
Min. switching capacity
#1
100 mA, 5 V DC
Expected
life
Mechanical (at 180 cpm) 5×10
7
(AC), 10
6
(DC)
Electrical
(resistive)
15 A 125 V
AC
5×10
5
10 A 250 V
AC
5×10
5
5×10
5
3 A 30 V DC 5×10
5
5×10
5
Max. operating speed 20 cpm
Initial insulation resistance*
1
Min. 100 M (at 500 V DC)
Initial
breakdown
voltage*
2
Between contact sets 1,500 Vrms for 1 min.
Between open contacts 1,000 Vrms for 1 min.
Between contacts and coil 2,000 Vrms for 1 min.
Operate time (at nominal voltage)
Max. 25 ms (DC type)
Max. 25 ms (AC type)
Release time*
3
(without diode)
(at nominal voltage)
Max. 25 ms (DC type)
Max. 25 ms (AC type)
Temperature rise, max.
(at nominal voltage)
Max. 80°C
Shock resistance
Functional*
4
Min. 196 m/s
2
{20 G}
Destructive*
5
Min. 980 m/s
2
{100 G}
Vibration resistance
Functional*
6
10 to 55 Hz
at double amplitude of 1 mm
Destructive
10 to 55 Hz
at double amplitude of 2 mm
Conditions for operation,
transport and storage*
7
(Not freezing and
condensing at low
temperature)
Ambient
temperature
–50°C to +70°C
–58°F to +158°F
Humidity 5 to 85% R.H.
Unit weight Approx. 35 g 1.25 oz
TYPICAL APPLICATIONS
Power station control equipment,
refrigerators, building control equipment,
office machines, and medical equipment.
ORDERING INFORMATION
2HHLEx.
Contact arrangement
AC240V
Terminal arrangement Coil voltage
Note: Standard packing Carton: 20 pcs., Case: 200 pcs.
UL/CSA approved type is standard.
1: 1 Form C
2: 2 Form C
H: Plug-in
HP: PC board
HTM: Top mounting
L: Light emitting diode wired, plug-in
PL: Light emitting diode wired, PC board
AC 6, 12, 24, 48,
120, 240 V
DC 6, 12, 24, 48,
110 V
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
HL
COIL DATA (at 20
°
C 68
°
F)
DIMENSIONS
mm inch
Plug-in PC board*
1
Top mounting
HL1
(1 Form C)
DC coils
AC coils at 60 Hz
Coil voltage,
V DC
Pick-up voltage,
V DC (max.)
Drop-out voltage,
V DC (min.)
Max. allowable
voltage, V DC
Coil resistance,
(±10%)
Nominal coil
current, mA
Operating power, W
Nominal Minimum
6 4.8 0.6 6.6 40 150
0.90 0.58
12 9.6 1.2 13.2 160 75
24 19.2 2.4 26.4 650 37
48 38.4 4.8 52.8 2,600 18.5
110 88.0 11.0 121.0 10,000 10 1.0 0.64
Coil voltage,
V DC
Pick-up voltage,
V AC (max.)
Drop-out voltage,
V AC (min.)
Max. allowable
voltage, V AC
Nominal coil
current, mA
Operating power, VA
Nominal Minimum
6 4.8 1.8 6.6 200
1.20 0.77
12 9.6 3.6 13.2 100
24 19.2 7.2 26.4 50
48 38.4 14.4 52.8 25
110/120 88 36 132 10.9/11.9
220/240 176 72 264 6.0/6.5
Notes:
1. The range of coil current is ±15% for AC (60 Hz), ±10% for DC, at 20°C.
2. The relay may be used in the range of 80% to 110% of the nominal coil
voltage. However, it is recommended that the relay be used at 85% to
110% nominal voltage to take temporary voltage variations into
consideration.
3. Each coil resistance of DC types is the measured value at a coil
temperature of 20°C. Please allow a compensation of ±0.4%
resistance for each coil temperature change of ±1°C.
4. All AC 240 V types are rated for double coil voltages, both AC 220 V
and AC 240 V.
5. For use with 220 or 240 V DC, connect a resistor, as suggested below,
in series with the 110 V DC relay.
Voltage 1 Form C, 2 Form C
220 V DC
240 V DC
11 kW (5 W)
13 kW (5 W)
1.2
.047
Accepts Faston #187
Schematic
2
6
87
3
20.8
.819
27.2
1.071
6.35
.250
10
.394
3.95
.156
4.6
.181
6
.236
7.15
.281
35.4
1.394
14.2
.559
AC type DC type
8
7
()
()
3
2
6
8
7
()
(+)
3
2
6
20.8
.819
27.2
1.071
35.4
1.394
3
3
2
2
6
6
8
7
Schematic
1.2
.047
0.5
.020
1.5
.059
5
.197
3.5
.138
1.5
.059
78
AC type DC type
8
7
()
()
3
2
6
8
7
()
(+)
3
2
6
20.6
.811
43
1.693
3
3
2
6
87
2
6
8
7
Schematic
Accepts Faston #187
Mounting dimension
2-3.2 to 3.5 dia
2
.079
1.2
.047
2-.126 to .138 dia
6.35
.250
3.6
.142
35.4
1.354
37.6
1.480
37.6
1.480
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
HL
mm inch
Tolerance:
±
0.5
±
.020
ACCESSORIES
mm inch
Plug-in PC board*
1
Top mounting
HL2
(2 Form C)
20.8
.819
35.4
1.394
27.2
1.071
1.2
.047
6.35
.250
10
.394
14.2
.559
3.7
.146
4.7
.185
6
.236
7.3
.287
1
3
5
7
Accepts Faston #187
8
2
4
6
Schematic
AC type DC type
8
7
()
()
3
2
6
8
7
()
(+)
3
2
6
27.2
1.071
1.2
.047
0.5
.020
1.5
.059
20.8
.819
35.4
1.394
3.5
.138
1.5
.059
1
78
1
3
5
78
2
4
6
3
5
2
4
6
Schematic
5
.197
AC type DC type
8
7
()
()
3
2
6
8
7
()
(+)
3
2
6
20.6
.811
37.6
1.480
37.6
1.480
2
.079
43
1.693
1.2
.047
1
1
2
4
65
3
87
3
5
2
4
6
78
Schematic
Accepts Faston #187
Mounting dimension
2-3.2 to 3.5 dia.
2-.126 to .138 dia.
6.35
.250
3.6
.142
34.4
1.354
*
1
PC board pattern
Copper-side view
(HL1) (HL2)
5-2 dia.
5-.079 dia.
7.15
.281
17.75
.700
8.5
.335
14.2
.559
4.6
.181
6
.236
4
.158
4
.158
4
.158
10
.394
1.25
.049
1.25
.049
1.25
.049
R3
R2
8-2 dia.
8-.079 dia.
7.3
.287
18
.709
13.3
.524
14.2
.559
2
.079
10
.394
2
.079
R2
R2
Tolerance: ±0.1 ±.004
HL1-SS-K (with hold-down clip)
25.5
1.004
18.7
.736
11.2 .441
29.4
1.157
Accepts Faston #187
0.23
.009
4.75
.187
Panel cutout
25.8
1.016
21.6
.850
HL2-SS-K (with hold-down clip)
25.5
1.004
18.7
.736
11.2 .441
29.4
1.157
Accepts Faston #187
0.23
.009
4.75
.187
Panel cutout
25.8
1.016
21.6
.850
Plug-in terminal socket mount
Simply insert socket into panel hole and
push down as indicated to lock socket in
place.
Panel cutout for tandem mounting
Tolerance: ±0.1 ±.004
1.0 to 2.0
.039 to .079 Panel thickness
25.8
1.016
8.9
.350
25.8
1.016
21.6
.850
21.6
.850
5.9
.232
Minimum
separation distance
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.

HL2-H-DC6V

Mfr. #:
Manufacturer:
Panasonic Industrial Devices
Description:
Relay Sockets & Hardware High Cap Power Relay Plug-In
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union