SELECTION TABLE:
PART
NUMBER
PART
NUMBER
MAX
kBITS/SEC
EXTERNAL
CAPACITORS
MAX
SUPPLY
SHUTDOWN AND
TRI-STATE
FEATURES
01 MAX220 20 0.047/0.33 2 NO Lowest power
02 MAX222 116 0.1 10 YES/NO _____
SHDN
03 MAX232A 116 0.1 10 NO High Speed
04 MAX242 116 0.1 10 YES/YES __ _____
EN, SHDN
05 MAX243 116 0.1 10 NO Open-Line
Detect
QUALITY ASSURANCE
Sampling and inspection procedures shall be in accordance with MIL-Prf-38535, Appendix A as specified in Mil-Std-
883.
Screening shall be in accordance with Method 5004 of Mil-Std-883. Burn-in test Method 1015:
1. Test Condition, A, B, C, or D.
2. T
A
= +125
o
C minimum.
3. Interim and final electrical test requirements shall be specified in Table 2.
Quality conformance inspection shall be in accordance with Method 5005 of Mil-Std-883, including Groups A, B, C,
and D inspection.
Group A inspection:
1. Tests as specified in Table 2.
2. Selected subgroups in Table 1, Method 5005 of Mil-Std-883 shall be omitted.
Group C and D inspections:
a. End –point electrical parameters shall be specified in Table 1.
b. Steady-state life test, Method 1005 of Mil-Std-883:
1. Test condition A, B, C, D.
2. T
A
= +125
o
C minimum.
3. Test duration, 1000 hours, except as permitted by Method 1005 of Mil-Std-883.
TABLE 2. ELECTRICAL TEST REQUIREMENTS
Mil-Std-883 Test Requirements Subgroups per Method 5005, Table 1
Interim Electrical Parameters
Method 5004
1
Final Electrical Parameters
Method 5005
1*, 2, 3, 9, 10, 11
Group A Test Requirements
Method 5005
1, 2, 3, 9, 10, 11
Group C and D End-Point Electrical Parameters
Method 5005
1
* PDA applies to Subgroup 1 only.