SPECIFICATION OF VDE MARKS LICENSE DOCUMENT
Parameter Symbol Spec. Unit
Climatic test class (IEC 60068-1/DIN EN 60068-1) 40/100/21
Dielectric strength
maximum operating isolation voltage
Test voltage (partial discharge test, procedure a for type test and
random test)
U
pr
= 1.6 × U
IORM
, P
d
< 5 pC
U
IORM
U
pr
707
1 131
V
peak
V
peak
Test voltage (partial discharge test, procedure b for all devices)
U
pr
= 1.875 × U
IORM
, P
d
< 5 pC
U
pr
1 326 V
peak
Highest permissible overvoltage U
TR
6 000 V
peak
Degree of pollution (DIN EN 60664-1 VDE0110 Part 1) 2
Comparative tracking index (IEC 60112/DIN EN 60112 (VDE 0303
Part 11))
CTI 175
Material group (DIN EN 60664-1 VDE0110 Part 1) III a
Storage temperature range T
stg
–55 to +125 °C
Operating temperature range T
A
–40 to +100 °C
Isolation resistance, minimum value
V
IO
= 500 V dc at T
A
= 25°C
V
IO
= 500 V dc at T
A
MAX. at least 100°C
Ris MIN.
Ris MIN.
10
12
10
11
Ω
Ω
Safety maximum ratings (maximum permissible in case of fault, see
thermal derating curve)
Package temperature
Current (input current I
F
, P
si
= 0)
Power (output or total power dissipation)
Isolation resistance
V
IO
= 500 V dc at T
A
= Tsi
Tsi
Isi
Psi
Ris MIN.
150
200
300
10
9
°C
mA
mW
Ω