10
LT1086 Series
sn1086 1086ffs
APPLICATIONS INFORMATION
WUU
U
Load Regulation
Because the LT1086 is a 3-terminal device, it is not
possible to provide true remote load sensing. Load regu-
lation will be limited by the resistance of the wire connect-
ing the regulator to the load. The data sheet specification
for load regulation is measured at the bottom of the
package. Negative side sensing is a true Kelvin connec-
tion, with the bottom of the output divider returned to the
negative side of the load. Although it may not be immedi-
ately obvious, best load regulation is obtained when the
top of the resistor divider R1 is connected
directly
to the
case
not to the load
, as illustrated in Figure 2. If R1 were
connected to the load, the effective resistance between the
regulator and the load would be:
R
P
, R
P
= Parasitic Line Resistance
R2 + R1
R1
()
Thermal Considerations
The LT1086 series of regulators have internal power and
thermal limiting circuitry designed to protect the device
under overload conditions. For continuous normal load
conditions however, maximum junction temperature rat-
ings must not be exceeded. It is important to give careful
consideration to all sources of thermal resistance from
junction to ambient. This includes junction-to-case, case-
to-heat sink interface and heat sink resistance itself. New
thermal resistance specifications have been developed to
more accurately reflect device temperature and ensure
safe operating temperatures. The data section for these
new regulators provides a separate thermal resistance and
maximum junction temperature for both the
Control Sec-
tion
and the
Power Transistor
. Previous regulators, with a
single junction-to-case thermal resistance specification,
used an average of the two values provided here and
therefore could allow excessive junction temperatures
under certain conditions of ambient temperature and heat
sink resistance. To avoid this possibility, calculations
should be made for both sections to ensure that both
thermal limits are met.
For example, using a LT1086CK (TO-3, Commercial) and
assuming:
V
IN
(max continuous) = 9V, V
OUT
= 5V, I
OUT
= 1A,
T
A
= 75°C, θ
HEAT SINK
= 3°C/W,
θ
CASE-TO-HEAT SINK
= 0.2°C/W for T package with
thermal compound.
Power dissipation under these conditions is equal to:
P
D
= (V
IN
– V
OUT
)(I
OUT
) = 4W
Junction temperature will be equal to:
T
J
= T
A
+ P
D
(θ
HEAT SINK
+ θ
CASE-TO-HEAT SINK
+ θ
JC
)
For the Control Section:
T
J
= 75°C + 4W(3°C/W + 0.2°C/W + 1.5°C/W) = 94.6°C
95°C < 125°C = T
JMAX
(Control Section
Commercial Range)
For the Power Transistor:
T
J
= 75°C + 4W(3°C/W + 0.2°C/W + 4°C/W) = 103.8°C
103.8°C < 150°C = T
JMAX
(Power Transistor
Commercial Range)
LT1086 OUTINV
IN
ADJ
R
P
PARASITIC
LINE RESISTANCE
R1*
*CONNECT R1 TO CASE
CONNECT R2 TO LOAD
1086 • F02
R
L
R2*
Figure 2. Connections for Best Load Regulation
Connected as shown, R
P
is not multiplied by the divider
ratio. R
P
is about 0.004 per foot using 16-gauge wire.
This translates to 4mV/ft at 1A load current, so it is
important to keep the positive lead between regulator and
load as short as possible and use large wire or PC board
traces.
Note that the resistance of the package leads for the H
package 0.06/inch. While it is usually not possible to
connect the load directly to the package, it is possible to
connect larger wire or PC traces close to the case to avoid
voltage drops that will degrade load regulation.
For fixed voltage devices the top of R1 is internally Kelvin
connected and the ground pin can be used for negative
side sensing.
11
LT1086 Series
sn1086 1086ffs
APPLICATIONS INFORMATION
WUU
U
In both cases the junction temperature is below the
maximum rating for the respective sections, ensuring
reliable operation.
Junction-to-case thermal resistance for the K and T pack-
ages is specified from the IC junction to the bottom of the
case directly below the die. This is the lowest resistance
path for heat flow. While this is also the lowest resistance
path for the H package, most available heat sinks for this
package are of the clip-on type that attach to the cap of the
package. The data sheet specification for thermal resis-
tance for the H package is therefore written to reflect this.
SCSI-2 Active Termination
TYPICAL APPLICATIONS
U
5V, 1.5A Regulator
10µF
TANTALUM
4.25V
TO 5.25V
1N5817
TERMPWR
LT1086 • TA03
10µF
TANTALUM
0.1µF
CERAMIC
18 TOTAL
110
2%
110
110
110
110
2%
110
2%
LT1086-2.85IN OUT
GND
+ +
V
IN
6.5V 5V AT 1.5A
*REQUIRED FOR STABILITY
LT1086
LT1086 • AI02
10µF*
TANTALUM
121
1%
365
1%
10µF
IN OUT
ADJ
+
+
In all cases proper mounting is required to ensure the best
possible heat flow from the die to the heat sink. Thermal
compound at the case-to-heat sink interface is strongly
recommended. In the case of the H package, mounting the
device so that heat can flow out the bottom of the case will
significantly lower thermal resistance ( a factor of 2). If
the case of the device must be electrically isolated, a
thermally conductive spacer can be used as long as its
added contribution to thermal resistance is considered.
Note that the case of all devices in this series is electrically
connected to the output.
12
LT1086 Series
sn1086 1086ffs
TYPICAL APPLICATIONS
U
1.2V to 15V Adjustable Regulator
IN
V
IN
OUT
TTL
ADJ
1k
1k
10µF
100µF
5V
LT1086
2N3904
LT1086 • TA05
+
121
1%
365
1%
+
5V Regulator with Shutdown
IN OUT
ADJ
R2
5k
C1*
10µF
V
OUT
V
IN
LT1086
LT1086 • TA04
+
C2
100µF
+
R1
121
*NEEDED IF DEVICE IS FAR FROM FILTER CAPACITORS
V
OUT
= 1.25V 1 +
R2
R1
(
)
+
LT1086 OUTIN
V
IN
V
IN
RETURN
ADJ
R
P
(MAX DROP 300mV)
121
365
25
10µF
5µF
100µF
LT1086 • TA09
R
L
V
OUT
5V
RETURN
25
2
6
7
1
8
100pF
3
4
+
1k
LM301A
+
+
Remote Sensing
Regulator with Reference Protected High Current Lamp Driver
V
IN
> 11.5V 10V
LT1086-5
LT1086 • TA08
100µF
LT1029
5V
10µF
IN OUT
GND
++
Battery Charger
V
IN
V
OUT
R2
I
F
R
S
R1
LT1086
1.25V
LT1086 • TA06
R2
R1
1 +V
OUT
– 1.25
()
R2
R1
1 + – R
S
I
F
=
()
1
R2
R1
1 + – R
S
=
()
dI
F
dV
OUT
()
IN
OUT
ADJ
Adjusting Output Voltage of Fixed Regulators
V
IN
> 12V 5V TO 10V
*OPTIONAL IMPROVES RIPPLE REJECTION
LT1086-5
LT1086 • TA07
100µF
1k
10µF
10µF*
IN OUT
GND
+ +
+
TTL OR
CMOS
15V
10k
LT1086
ADJ
INOUT
LT1086 • TA10
12V
1A

LT1086CM-3.6#TRPBF

Mfr. #:
Manufacturer:
Analog Devices / Linear Technology
Description:
LDO Voltage Regulators 3.6V L/Dropout Pos VR 1.5A
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union