Absolute Maximum Ratings (@ 25˚ C)
2
Parameter Min Typ Max Units
Supply Voltages ± 5 - ±18 V
Differential Input Voltage - - ± 30 V
Output Short Circuit Duration Continuous -
Total Package Dissipation - - 11 W
Isolation Voltage
Input to Output 3750 - - V
RMS
Operational Temperature -40 - +85 °C
Storage Temperature -40 - +125 °C
Soldering Temperature
DIP Package - - +260 °C
Surface Mount Package - - +220 °C
(10 Seconds Max.)
1
Above 25°C Derate Linearly 1.67mW/°C
Electrical Characteristics @ TA = +25°C and
±VCC = 15VDC (unless otherwise specified)
PARAMETERS CONDITIONS MIN TYP MAX UNITS
Isolation
Continuous Voltage, AC - - - 3750 V
RMS
Input to Output Leakage Current 1000V
RMS
, 60Hz - 0.2 - µA
RMS
Offset Voltage
Output Offset Voltage (VOS) R
F
=R
IN
=51KΩ, K3=1.000 - 50 - mV
Input Grounded T
A
=25°C
Amplifier Input Impedance - - 10
12
|| 3 - Ω || pF
∆VOS/∆T Average TC of Input
Offset Voltage R
S
=50Ω -5-µV/°C
(Input and Output Stage)
Common Mode Rejection Ratio, CMRR 60Hz, R
F
=1MΩ - 100 - dB
R
IN
=10KΩ, Gain=100
Input Offset Voltage R
S
=50Ω, T
A
=25°C - 3 10 mV
Common Mode Range ±12 - - V
Frequency Response
Bandwidth - - 40 - kHz
Slew Rate 0-10V Step Input - 0.3 - V/µs
Non-Linearity F
O
=300Hz, -10dBm - - 0.01 %
Power Supplies
Input Stage Supply Voltage VCC1, VEE1 - ±5 - ±18 V
Output Stage Supply Voltage VCC2, VEE2 - ±5 - ±18 V
Input (A1) & Output Stage (A2) Supply Current - - 5 10 mA
Power Supply Rejection Ratio, PSRR - - 80 100 dB