1
☎
USA (847) 827-7600 - CANADA (905) 764-9510Issue C
57
Authority Voltage ratings Current ratings
CSA, UL AC 250 V 0.63...10 A
DC 48 V 0.63... 8 A
UL DC 60 V 0.63... 5 A
SEV (EN 60934) AC 240 V 0.63... 4 A
DC 28 V 0.63... 8 A
Voltage rating AC 240 V; DC 28 V
(AC 250 V; DC 48) up to 10A UL/CSA
DC 60 V up to 5A
Current rating range 0.63...10 A
Typical life
circuit 1-3 30,000 operations for I
N
≤ 6.3 A AC/DC
10,000 operations for I
N
> 6.3 A AC
3,000 operations for I
N
> 6.3 A DC
protection circuit 1-2 300 break operations at 2 x I
N
Ambient temperature -40...+70 °C (-40...+158 °F)
Insulation co-ordination Rated impulse Pollution
(IEC 60664 and 60664A) withstand voltage degree
2.5 kV 2
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A) Test voltage
operating area AC 3,000 V
Insulation resistance > 100 MΩ (DC 500 V)
Interrupting capacity I
cn
0.63...2 A 12 x I
N
2.5 ...8 A 8 x I
N
, AC max. 50 A
10 A 6 x I
N
3.15...10 A 10 x I
N
, DC
Interrupting capacity 0.63...10 A 2,000 A AC 250 V
(UL 1077) 0.63... 8 A 200 A DC 48 V
0.63... 5 A 200 A DC 60 V
Degree of protection operating area IP 30
(IEC 60529/DIN 40050) terminal area IP 00
Vibration 8 g (57-500 Hz) ±0.61 mm (10-57 Hz),
to IEC 60068-2-6, Test Fc,
10 frequency cycles/axis
Shock 20 g (11 ms)
to IEC 60068-2-27, test Ea
Corrosion 48 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
Humidity 96 hours at 95 % RH
to IEC 60068-2-3, test Ca
Mass approx. 9 g
Thermal Overcurrent Circuit Breaker 1410-F1...
Miniaturised single pole rocker switch/thermal circuit breaker combining
ON/OFF switching and extremely fast overload performance in a single
component (S-type TO CBE to EN 60934/IEC 60934). Under overload
conditions an internal neon (filament bulb for low voltages) illuminates to
give a clear signal of the tripped status of the mechanism and thereby the
cause of power interruption, suffix -B. Alternatively the illumination can be
conventionally wired to indicate the ON status of the device, suffix -E.
Returning the rocker switch through the OFF position and back ON will
reset the mechanism and restore the supply. Largely temperature-insen-
sitive.
Description
Ordering information
Technical data
1410-F1..
Approvals
Typical applications
Motors, transformers, solenoids, PCBs, hand-held machines,
appliances, instrumentation.
Standard current ratings and typical internal resistance values
Current Internal Current Internal
rating (A) resistance (Ω) rating (A) resistance (Ω)
0.63 1.8
0.8 1.7
1 1.3
1.5 < 1
1.8 < 1
2< 1
2.5 < 0.15
3.15 < 0.12
4 < 0.1
5 < 0.1
6.3 < 0.1
8 < 0.1
10 < 0.1
Type No.
1410 single pole rocker switch/circuit breaker
Mounting
F snap-in panel mounting
Size of frame
1 to fit mounting cut-out 28 x 12.7 mm (1.1 x .5 in)
Number of poles
1 single pole, thermally protected
Accessories
0without accessories
Terminal design
P1 blade terminals 2.8-0.8 (QC .110/2x.110)silver-plated
Characteristic curve
F1 fast acting
Actuator style
Wrocker, rounded profile
Actuator colour
14 red translucent
19 green translucent
Actuator markings
Q I and 0
Trip/ON illumination (optional)
B illuminated when tripped
E illuminated when ON
.. without illumination
Illumination voltage range
(optional)
2
20- 28V marked 24V 35mA
3 90-140V marked 115V <1mA
4 185-275V marked 230V <1mA
Current ratings
0.63...10 A
1410 - F 1 1 0 - P1 F1 - W 14 Q E 3 - 2 A ordering example
The exact part number required can be built up from the table of choices shown
above. Ordering references for optional features should be omitted if not required.
Packaging quantities: 100, 250, 300, 400, 500 or 1,000 pcs