1410-F110-P1F1-W19QE2-2A

1
USA (847) 827-7600 - CANADA (905) 764-9510Issue C
57
Authority Voltage ratings Current ratings
CSA, UL AC 250 V 0.63...10 A
DC 48 V 0.63... 8 A
UL DC 60 V 0.63... 5 A
SEV (EN 60934) AC 240 V 0.63... 4 A
DC 28 V 0.63... 8 A
Voltage rating AC 240 V; DC 28 V
(AC 250 V; DC 48) up to 10A UL/CSA
DC 60 V up to 5A
Current rating range 0.63...10 A
Typical life
circuit 1-3 30,000 operations for I
N
6.3 A AC/DC
10,000 operations for I
N
> 6.3 A AC
3,000 operations for I
N
> 6.3 A DC
protection circuit 1-2 300 break operations at 2 x I
N
Ambient temperature -40...+70 °C (-40...+158 °F)
Insulation co-ordination Rated impulse Pollution
(IEC 60664 and 60664A) withstand voltage degree
2.5 kV 2
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A) Test voltage
operating area AC 3,000 V
Insulation resistance > 100 M (DC 500 V)
Interrupting capacity I
cn
0.63...2 A 12 x I
N
2.5 ...8 A 8 x I
N
, AC max. 50 A
10 A 6 x I
N
3.15...10 A 10 x I
N
, DC
Interrupting capacity 0.63...10 A 2,000 A AC 250 V
(UL 1077) 0.63... 8 A 200 A DC 48 V
0.63... 5 A 200 A DC 60 V
Degree of protection operating area IP 30
(IEC 60529/DIN 40050) terminal area IP 00
Vibration 8 g (57-500 Hz) ±0.61 mm (10-57 Hz),
to IEC 60068-2-6, Test Fc,
10 frequency cycles/axis
Shock 20 g (11 ms)
to IEC 60068-2-27, test Ea
Corrosion 48 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
Humidity 96 hours at 95 % RH
to IEC 60068-2-3, test Ca
Mass approx. 9 g
Thermal Overcurrent Circuit Breaker 1410-F1...
Miniaturised single pole rocker switch/thermal circuit breaker combining
ON/OFF switching and extremely fast overload performance in a single
component (S-type TO CBE to EN 60934/IEC 60934). Under overload
conditions an internal neon (filament bulb for low voltages) illuminates to
give a clear signal of the tripped status of the mechanism and thereby the
cause of power interruption, suffix -B. Alternatively the illumination can be
conventionally wired to indicate the ON status of the device, suffix -E.
Returning the rocker switch through the OFF position and back ON will
reset the mechanism and restore the supply. Largely temperature-insen-
sitive.
Description
Ordering information
Technical data
1410-F1..
Approvals
Typical applications
Motors, transformers, solenoids, PCBs, hand-held machines,
appliances, instrumentation.
Standard current ratings and typical internal resistance values
Current Internal Current Internal
rating (A) resistance () rating (A) resistance ()
0.63 1.8
0.8 1.7
1 1.3
1.5 < 1
1.8 < 1
2< 1
2.5 < 0.15
3.15 < 0.12
4 < 0.1
5 < 0.1
6.3 < 0.1
8 < 0.1
10 < 0.1
Type No.
1410 single pole rocker switch/circuit breaker
Mounting
F snap-in panel mounting
Size of frame
1 to fit mounting cut-out 28 x 12.7 mm (1.1 x .5 in)
Number of poles
1 single pole, thermally protected
Accessories
0without accessories
Terminal design
P1 blade terminals 2.8-0.8 (QC .110/2x.110)silver-plated
Characteristic curve
F1 fast acting
Actuator style
Wrocker, rounded profile
Actuator colour
14 red translucent
19 green translucent
Actuator markings
Q I and 0
Trip/ON illumination (optional)
B illuminated when tripped
E illuminated when ON
.. without illumination
Illumination voltage range
(optional)
2
20- 28V marked 24V 35mA
3 90-140V marked 115V <1mA
4 185-275V marked 230V <1mA
Current ratings
0.63...10 A
1410 - F 1 1 0 - P1 F1 - W 14 Q E 3 - 2 A ordering example
The exact part number required can be built up from the table of choices shown
above. Ordering references for optional features should be omitted if not required.
Packaging quantities: 100, 250, 300, 400, 500 or 1,000 pcs
USA (847) 827-7600 - CANADA (905) 764-9510 Issue C
1
58
Thermal Overcurrent Circuit Breaker 1410-F1...
Dimensions
Typical time/current characteristics at +23°C/+73.4°F
Installation drawing
Internal connection diagram
1410-F...-....-....E.
1410-F...-....-....B. 1410-F...-....-....B. 1410-F...-....-....E.
blade terminals
DIN 46244-C
(QC 2x.110)
blade terminal
DIN 46244-A2.8-0.8
(QC .110)
.039
1.10
+.008
12.7
+0.3
R
.0
0
8
+.008
0.8 … 3
2
0
°
20°
ON
OFF
.925
mounting hole
sharp edged
1.27
illuminated trip indication
.201
.472
.083
.295
.197
1.26
1.09
.118
.256
.835
.913
.374
.118
.670
.059
.354
.039
.346
.472
.630
.531
.039
.236
45°
16
13.5 1
6
27.6
32
6.5
3
9.5
3
23.2
21.2
5.1
7.5
1
12
23.5
2.1
32.3
1.5
5
17
9
1
8.8
12
28
+0.2
.500
+.012
R
0
.2
+0.2
.031 … .118
13.5
20°
20°
2
0
°
.630
.531
.039
.236
45°
16
1
6
.197
.670
.059
.354
.039
.346
.472
1.5
5
17
9
1
8.8
12
blade terminals
DIN 46244-C
(QC 2x.110)
.039
ON
OFF
.925
1.27
.201
.472
.083
.295
1.26
1.09
.256
.835
.374
.118
27.6
32
6.5
3
9.5
3
23.2
21.2
5.1
7.5
1
12
23.5
2.1
32.3
.118
.913
.079
blade terminal
DIN 46244-A2.8-0.8
(QC .110)
.409
.835
illuminated trip indication
10.4
21.2
.409
.835
10.4
21.2
11.5
.453
.110
2
2.8
lamp current
24 V = 35 mA
115 V < 1 mA
230 V < 1 mA
14 213 2
LINELINE
12 468102040
… times rated current
Trip time in seconds
10000
1000
100
10
1
0.1
0.01
10
.394
10
.394
mounting area
operating area
10
32
1.26
.394
10
.394
10
.394
This is a metric design and millimeter dimensions take precedence ( )
mm
inch
All dimensions without tolerances are for reference only. In the interest of improved design,
performance and cost effectiveness the right to make changes in these specifications without
notice is reserved.Product markings may not be exactly as the ordering codes. Errors and
omissions excepted.
1
USA (847) 827-7600 - CANADA (905) 764-9510Issue C
59
0.63 1.8 3.15 < 0.12
0.8 1.7 4 < 0.1
1 1.3 4.5 < 0.1
1.25 < 1 5 < 0.1
1.5 < 1 6.3 < 0.1
1.8 < 1 8 < 0.1
2< 1 10< 0.1
2.5 < 0.15
Voltage rating AC 240 V; DC 28 V
(AC 250 V; DC 50 V UL/CSA)
Current rating range 1-2 0.63...10 A
Auxiliary circuit 1-3 0.2 x I
N
max. 1 A, AC 250 V
style -L2 and -G1 only
Typical life 300 operations at 2 x I
N
(-L2...)
500 operations at 2 x I
N
(-L1../-G1..)
Ambient temperature -20...+100 °C (-4...+212 °F)
Insulation co-ordination Rated impulse Pollution
(IEC 60664 and 60664A) withstand voltage degree
2.5 kV 2
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A) Test voltage
operating area AC 1,500 V
Insulation resistance > 100 M (DC 500 V)
Interrupting capacity I
cn
0.63...2 A 12 x I
N
(o-o-o) 2.5 ...8 A 8 x I
N
, AC max. 50 A
10 A 6 x I
N
, AC
3.15...10 A 10 x I
N
, DC
Interrupting capacity 0.63...10 A 2,000 A AC 250 V
(UL 1077) 0.63...10 A 200 A DC 50 V
Degree of protection operating area IP 40
(IEC 60529/DIN 40050) terminal area IP 00
Vibration 8 g (57-500 Hz) ±0.61 mm (10-57 Hz),
to IEC 60068-2-6, Test Fc,
10 frequency cycles/axis
Shock 20 g (11 ms)
to IEC 60068-2-27, test Ea
Corrosion 48 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
Humidity 96 hours at 95 % RH
to IEC 60068-2-3, test Ca
Mass approx. 5 g
Thermal Overcurrent Circuit Breaker 1410-L/-G...
Description
Single pole press-to-reset thermal circuit breaker with extremely fast
overload switching performance (R-type TO CBE to EN 60934). Single
hole threadneck, PCB or integral mounting with a choice of designs.
Miniaturized construction minimizes PCB real estate required. Type
1410-L2 and 1410-G1 versions feature changeover contacts suitable
for providing status output signals. Largely temperature-insensitive.
Typical applications
Motors, transformers, solenoids, PCBs, hand-held machines, ap-
pliances, instrumentation.
Ordering information Technical data
1410-L1... 1410-L2... 1410-G1...
Approvals
Authority Voltage rating Current ratings
VDE AC 240 V 0.63...10 A
DC 50 V 0.63...2.5 A
DC 28 V 2.5 ...10 A
UL, CSA AC 250 V; DC 50 V 0.63...10 A
Standard current ratings and typical internal resistance values
Current Internal Current Internal
rating (A) resistance () rating (A) resistance ()
All dimensions without tolerances are for reference only. In the interest of improved design,
performance and cost effectiveness the right to make changes in these specifications without
notice is reserved.Product markings may not be exactly as the ordering codes. Errors and
omissions excepted.
Type No.
1410 single pole circuit breaker
Configuration
L PCB mounting
G threadneck panel mounting
Mounting
1 threadneck 3/8-27 UNS-2A (1410-G)
1 PCB 16.3x4.6 grid (1410-L) .642 x .181
2 PCB 10.15x7.6 grid (1410-L) .400 x .299
Number of poles
1 1 pole, thermally protected
Hardware
0 without
1with hex nut and knurled nut (1410-G only) bulk shipped
Terminal design
L1 solder pins 1.8x0.8 silver-plated (-L1 only)
L2 solder pins 1x0.8 silver-plated (-L2 and -G1 only)
P2
blade terminals A2.8-0.8 (QC .110) silver-plated (-G1 only)
Characteristic curve
F1 fast acting
Actuator
Smanual re-set
Actuator colour
01 black (for -G1.. and -L1..)
02 white (for -L2..)
Current ratings
0.63 ... 10 A
1410- L 1 1 0 - L1 F1 - S 01 - 0.8 A ordering example
Packaging quantities: 100, 250, 300, 400, 500 or 1,000 pcs

1410-F110-P1F1-W19QE2-2A

Mfr. #:
Manufacturer:
E-T-A Circuit Breakers
Description:
Circuit Breakers Thermal circuit breaker for snap-in panel mounting, rocker operated, fast acting
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet