9AD0901M121

416
AC
ACDC Fan 92mm
Wiring Diagram
Specications for Low-speed Sensors
VCE=+27.6 V DC MAX.
Ic
10 mA MAX.VCE (SAT) 1.0 V MAX.
Sensor scheme
HH
L
Fan power
Fan speed
Trip point
Sensor output
Startup delay
Detection delay
Example 2: when the rotor is locked when the fan motor is
turned on and released after the start-up delay time.
HH
L
Fan power
Fan speed
Trip point
Sensor output
Startup delay
Detection delay
Example 1: when steady running
VCE (SAT) = 1.0 V MAX.
Typical standard model: 9AD0901H1H
Output circuit: Open collector
Inside of DC fan
Pull-up resistor
Pull-up voltage
27.6 V DC MAX.
Photocoupler
Ic10 mA MAX.
Sensor
Sensor output
(V
CE)
9AD0901M1H
Startup delay: 36±3 s
Detection delay: 3 s MAX.
Trip point: 850 min
-1
9AD0901H1H
Startup delay: 18±3 s
Detection delay: 3 s MAX.
Trip point: 1,700 min
-1
FAN
FAN
Photocoupler
Yellow
Black
10 mA MAX.
+27.6 V MAX.
Senser output
GND (0 V)
Standard with Sensor
AC Power supply
AC Power supply
Pull-up resistor

9AD0901M121

Mfr. #:
Manufacturer:
Sanyo Denki
Description:
AC Fans AC, DC Fan, 92x38mm, 100VAC to 240VAC, Wide Voltage Range, Low Power, High Performance, Long Life, Ribless
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union