Data Sheet ADuM4150
Rev. B | Page 11 of 21
PACKAGE CHARACTERISTICS
Table 10.
Parameter Symbol Min Typ Max Unit Test Conditions/Comments
Resistance (Input to Output)
1
I-O
12
Capacitance (Input to Output)
1
C
I-O
1.0 pF f = 1 MHz
Input Capacitance
2
C
I
4.0 pF
IC Junction-to-Ambient Thermal Resistance θ
JA
46 °C/W Thermocouple located at center of package underside
1
The device is considered a 2-terminal device: Pin 1 through Pin 10 are shorted together, and Pin 11 through Pin 20 are shorted together.
2
Input capacitance is from any input data pin to ground.
REGULATORY INFORMATION
The ADuM4150 is approved by the organizations listed in Table 11. See Table 16 and the Insulation Lifetime section for recommended
maximum working voltages for specific cross-isolation waveforms and insulation levels.
Table 11.
UL CSA VDE
Recognized Under UL 1577 Component
Recognition Program
1
Approved under CSA Component Acceptance
Notice 5A
Certified according to DIN V VDE V 0884-10
(VDE V 0884-10):2006-12
2
5000 V rms Single Protection Basic insulation per CSA 60950-1-07+A1+A2
and IEC 60950-12nd Ed+A1+A2., 800 V rms
(1131 V peak) maximum working voltage
3
Reinforced insulation, 849 V peak
Reinforced Insulation per CSA 60950-1-
07+A1+A2 and IEC 60950-1 2
nd
Ed.+A1+A2,
400 V rms (565 V peak) maximum working
voltage
Reinforced insulation (2MOPP) per IEC 60601-1
Ed.3.1, 250 V rms (353 V peak) maximum
working
File E214100 File 205078 File 2471900-4880-0001
1
In accordance with UL 1577, each model is proof tested by applying an insulation test voltage ≥ 6000 V rms for 1 second (current leakage detection limit = 10 µA).
2
In accordance with DIN V VDE V 0884-10, each model is proof tested by applying an insulation test voltage ≥ 1590 V peak for 1 second (partial discharge detection limit = 5 pC).
The asterisk (*) marked on the component designates DIN V VDE V 0884-10
approval.
3
Use at working voltages above 400 V
AC
RMS
shortens lifetime of the isolator significantly. See Table 16 for recommended maximum working voltages under ac and dc conditions.
INSULATION AND SAFETY RELATED SPECIFICATIONS
Table 12.
Parameter Symbol Value Unit Conditions
Rated Dielectric Insulation Voltage 5000 V rms 1-minute duration
Minimum External Air Gap (Clearance) L(I01) 8.3 mm min Measured from input terminals to output terminals,
shortest distance through air
Minimum External Tracking (Creepage) L(I02) 8.3 mm min Measured from input terminals to output terminals,
shortest distance path along body
Minimum Internal Gap (Internal Clearance) 0.017 mm min Insulation distance through insulation
Tracking Resistance (Comparative Tracking Index) CTI >400 V DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)