MC10EL35, MC100EL35
www.onsemi.com
4
Table 6. 100EL SERIES NECL DC CHARACTERISTICS (V
CC
= 0 V; V
EE
= −5.0 V (Note 1))
−40°C 25°C 85°C
Symbol Characteristic Min Typ Max Min Typ Max Min Typ Max Unit
I
EE
Power Supply Current 27 32 27 32 32 37 mA
V
OH
Output HIGH Voltage (Note 2) −1085 −1005 −880 −1025 −955 −880 −1025 −955 −880 mV
V
OL
Output LOW Voltage (Note 2) −1830 −1695 −1555 −1810 −1705 −1620 −1810 −1705 −1620 mV
V
IH
Input HIGH Voltage (Single-Ended) −1165 −880 −1165 −880 −1165 −880 mV
V
IL
Input LOW Voltage (Single-Ended) −1810 −1475 −1810 −1475 −1810 −1475 mV
I
IH
Input HIGH Current 150 150 150
mA
I
IL
Input LOW Current 0.5 0.5 0.5
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
1. Input and output parameters vary 1:1 with V
CC
. V
EE
can vary +0.8 V / −0.5 V.
2. Outputs are terminated through a 50 W resistor to V
CC
− 2.0 V.-
Table 7. AC CHARACTERISTICS (V
CC
= 5.0 V; V
EE
= 0 V or V
CC
= 0 V; V
EE
= −5.0 V (Note 1))
−40°C 25°C 85°C
Symbol Characteristic Min Typ Max Min Typ Max Min Typ Max Unit
fmax Maximum Toggle Frequency 1.4 2.0 1.8 2.2 1.8 2.2 GHz
t
PLH
t
PHL
Propagation Delay CLK
to Output MR
290
225
515
450
740
675
350
275
525
450
700
625
395
350
570
525
745
700
ps
t
S
Setup Time J, K 150 0 150 0 150 0 ps
t
H
Hold Time J, K 250 100 250 100 250 100 ps
t
RR
Reset Recovery 400 200 400 200 400 200 ps
t
PW
Minimum Pulse Width
CLK, Reset
400 400 400 ps
t
JITTER
Cycle-to-Cycle Jitter 1.0 1.0 1.0 ps
t
r
t
f
Output Rise/Fall Times Q (20%−80%) 100 225 350 100 225 350 100 225 350 ps
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
1. 10 Series: V
EE
can vary +0.25 V / −0.5 V.
100 Series: V
EE
can vary +0.8 V / −0.5 V.