VDRS-240-48

cui.com
date 01/17/2013
page 1 of 7
SERIES: VDRS-240 DESCRIPTION: AC-DC DIN RAIL
MODEL
output
voltage
output
current
output
power
ripple
and noise
1
ef ciency
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
(%)
VDRS-240-24 24 10 240 240 91
VDRS-240-48 48 5 240 480 92
Note: 1. at full load, 230 Vac input, measured at 20MHz bandwidth with a 47 μF and 0.1 μF parallel cap on the output
2. 3 seconds or 20% duty cycle max. The average output power should not exceed the rated power.
PART NUMBER KEY
VDRS - 240 - XX
Output
Voltage
Base Number
FEATURES
• up to 240 W continuous power
• universal input (88~264 Vac / 124~373 Vdc)
• 150% peak load capability
2
• DIN Rail power supplies
• two peak load mode selector
• built-in remote ON/OFF function
• over voltage, over load, and over temperature protections
• UL 508 and TUV safety approvals
• built-in active PFC function (PF 0.96)
• efficiency up to 92%
For more information, please visit the product page.
cui.com
date 01/17/2013 page 2 of 7CUI Inc SERIES: VDRS-240 DESCRIPTION: AC-DC DIN RAIL
INPUT
parameter conditions/description min typ max units
voltage
88
124
264
373
Vac
Vdc
frequency 47 63 Hz
current
at 115 Vac
at 230 Vac
2.6
1.3
A
A
inrush current
at 115 Vac
at 230 Vac
33
65
A
A
power factor correction 0.96
leakage current at 240 Vac 1mA
OUTPUT
parameter conditions/description min typ max units
voltage accuracy ±1 %
line regulation ±0.5 %
load regulation ±1 %
temperature coef cient (0 ~ 50°C) ±0.03 %/°C
hold-up time at 115 Vac, cold start 16 ms
voltage adjustment range -2 +8 %
Note: 1. All speci cation are measured at 230 Vac input, rated load, 25°C unless otherwise speci ed.
PROTECTIONS
parameter conditions/description min typ max units
over voltage protection
latch-off mode, restart
to recover from fault
24 V model
48 V model
120
117
138
135
%
%
Kicks in between 105~150% rated output power
when the fault persist for about 3 sec, then clamps
output voltage down, automatic recovery’ >150%
rated power or short circuit would cause the power
supply to go in to constant current limiting; if fault
condition is not removed after 5 times, then the
converter will shutdown and need to be restarted
to recover from fault.
over load protection
constant current limiting, automatically recovers
after fault condition is removed
105 150 %
over temperature protection
output shut down and auto restart upon reduction
of temperature
90 95 100 °C
DC ok relay contact ratings
at 0.3 A
at 1 A and 0.5 A
60
30
Vdc
Vdc
For more information, please visit the product page.
cui.com
date 01/17/2013 page 3 of 7CUI Inc SERIES: VDRS-240 DESCRIPTION: AC-DC DIN RAIL
SAFETY & COMPLIANCE
parameter conditions/description min typ max units
isolation voltage
input to output for 1 minute
input to case for 1 minute
output to case, output to DC OK for 1 minute
4,242
2,121
707
Vdc
Vdc
Vdc
isolation resistance
input to output, input to case,
output to case, 500 Vdc
100
MΩ
safety approvals UL 508, TUV EN 60950-1
EMI/EMC
2
EN 55022 Class B, EN 61000-3-3, EN 61204-3,
EN 55024, light industry level, criteria A, meet SEMI F47
RoHS compliant yes
Note: 2. The power supply is considered a component which will be installed into a nal equipment. The nal equipment must be re-con rmed that it still
meets EMC directives.
ENVIRONMENTAL
parameter conditions/description min typ max units
operating temperature -25 70 °C
storage temperature -40 85 °C
operating humidity non-condensing 20 95 %
storage humidity 10 95 %
vibration (10 ~ 500 Hz, 1 hour per axis, 3 hours total) 2 Grms
For more information, please visit the product page.