VDRS-240-24

cui.com
date 01/17/2013 page 4 of 7CUI Inc SERIES: VDRS-240 DESCRIPTION: AC-DC DIN RAIL
125.0
117.7
65.80
12
3
4
5
6
CN2
1
CN1
2
3
Relay Contact
DC ON
+V
ADJ.
35
+
SW1
SW2
ON OFF
MECHANICAL DRAWING
CN1
1
FG
2 ac line
3 ac neutral
CN2
1 DC+
2DC-
3 INH+
4 INH-
5 relay contact
6 relay contact
Switch
1 peak load setting
2 remote on/off setting
Admissible DIN-RAIL:
TS35/7.5 or TS35/15
MECHANICAL
parameter conditions/description min typ max units
dimensions 2.591 x 4.921 x 4.634 (65.8 x 125 x 117.7 mm) inch
For more information, please visit the product page.
cui.com
date 01/17/2013 page 5 of 7CUI Inc SERIES: VDRS-240 DESCRIPTION: AC-DC DIN RAIL
I
T
I-normal
I-peak
T-peak
T-normal
0
I
T
I-peak
T-peak
0
3 ~ 4 sec
0
2
4
6
8
10
12
14
16
18
20
22
24
10% 20% 30% 40% 50% 60% 70% 80% 90%
T-normal
I-normal
0
2
4
6
8
10
12
14
16
18
20
22
110% 115% 120% 125% 130% 135% 140% 145% 150%
T-peak
I-peak
T-peak presents while the unit is working within 110%~150% raterd output power.
See Curve “B” for the variation in T-Peak between output current and hold-up time.
If T-peak is more than the time setting in Curve “B”, the output current will drop to
the constant limit (I-normal) that is 105% of the rated power. Meanwhile, I-normal
and T-normal will be presenting. See Curve “A” for the timing back to I-Peak of
T-normal and this mode can be used for easy 2-stage battery chargers.
CURVE BCURVE A
T-peak presents while the unit is working within 110%~150% rated output power.
See Curve “B” for the variation of T-peak between output current and hold-up time.
If T-peak is more than the time setting in Curve “B”, the output voltage sill be shut
down for 3~4 seconds and then auto-recover.
PEAK LOADING SW1 ON
(
MODE1
)
DEFAULT SETTING
PEAK LOADING SW1 OFF
(
MODE2
)
For more information, please visit the product page.
cui.com
date 01/17/2013 page 6 of 7CUI Inc SERIES: VDRS-240 DESCRIPTION: AC-DC DIN RAIL
DERATING CURVE
Ambient temperature (°C)
Load (%)
Load
(%)
-25
40
50
40
60
100
80
125
150
60
100
80
40
60
20
0
88
Input Voltage (Vac) 60 Hz
264100
Output power vs. Ambient temperature Output power vs. Input Voltage
110 120
0
10 20 30
70
112.5
for 3 sec. typ.
continuous
50
ACTIVE DC SIGNAL - RELAY CONTACT
Contact Close When the output voltage reaches the adjusted output voltage
Contact Open When the output voltage drops below 45%
Contact Ratings (MAX) 30 V / 1 A resistive load
Note: 1. Derating may be needed under low input voltage. Please check the derating curve for more details.
REMOTE ON/OFF
The power supply can be turned on/off by using the “remote control” function.
12
3
4
5
6
Relay Contact
DC ON
+V
ADJ.
+
SW1
SW2
ON OFF
CN2
SW
External Power Source
I=6~20mA
SW2 INH+(3 PIN)/INH-(4 PIN) Output Status
off SW ON (>2.5 V) ENABLE
off SW OFF (<0.8 V) DISABLE
on SW ON (>2.5 V) DISABLE
on SW OFF (<0.8 V) ENABLE
(default setting)
For more information, please visit the product page.

VDRS-240-24

Mfr. #:
Manufacturer:
Description:
DIN Rail Power Supplies ac-dc, 240 W, 24 Vdc, single output, DIN rail
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet