Nexperia
74AUP1G3208
Low-power 3-input OR-AND gate
74AUP1G3208 All information provided in this document is subject to legal disclaimers. © Nexperia B.V. 2017. All rights reserved.
Product data sheet Rev. 7 — 7 March 2017
10 / 22
25 °C -40 °C to +125 °CSymbol Parameter Conditions
Min Typ
[1]
Max Min Max
(85 °C)
Max
(125 °C)
Unit
C
L
= 5 pF, 10 pF, 15 pF and 30 pF
f
i
= 1 MHz; V
I
= GND to V
CC
[3]
V
CC
= 0.8 V - 2.6 - - - - pF
V
CC
= 1.1 V to 1.3 V - 2.7 - - - - pF
V
CC
= 1.4 V to 1.6 V - 2.8 - - - - pF
V
CC
= 1.65 V to 1.95 V - 3.0 - - - - pF
V
CC
= 2.3 V to 2.7 V - 3.5 - - - - pF
C
PD
power
dissipation
capacitance
V
CC
= 3.0 V to 3.6 V - 4.0 - - - - pF
[1] All typical values are measured at nominal V
CC
.
[2] t
pd
is the same as t
PLH
and t
PHL
.
[3] C
PD
is used to determine the dynamic power dissipation (P
D
in μW).
P
D
= C
PD
× V
CC
2
× f
i
× N + Σ(C
L
× V
CC
2
× f
o
) where:
f
i
= input frequency in MHz;
f
o
= output frequency in MHz;
C
L
= output load capacitance in pF;
V
CC
= supply voltage in V;
N = number of inputs switching;
Σ(C
L
× V
CC
2
× f
o
) = sum of the outputs.