Nexperia
74AUP1G3208
Low-power 3-input OR-AND gate
74AUP1G3208 All information provided in this document is subject to legal disclaimers. © Nexperia B.V. 2017. All rights reserved.
Product data sheet Rev. 7 — 7 March 2017
10 / 22
25 °C -40 °C to +125 °CSymbol Parameter Conditions
Min Typ
[1]
Max Min Max
(85 °C)
Max
(125 °C)
Unit
C
L
= 5 pF, 10 pF, 15 pF and 30 pF
f
i
= 1 MHz; V
I
= GND to V
CC
[3]
V
CC
= 0.8 V - 2.6 - - - - pF
V
CC
= 1.1 V to 1.3 V - 2.7 - - - - pF
V
CC
= 1.4 V to 1.6 V - 2.8 - - - - pF
V
CC
= 1.65 V to 1.95 V - 3.0 - - - - pF
V
CC
= 2.3 V to 2.7 V - 3.5 - - - - pF
C
PD
power
dissipation
capacitance
V
CC
= 3.0 V to 3.6 V - 4.0 - - - - pF
[1] All typical values are measured at nominal V
CC
.
[2] t
pd
is the same as t
PLH
and t
PHL
.
[3] C
PD
is used to determine the dynamic power dissipation (P
D
in μW).
P
D
= C
PD
× V
CC
2
× f
i
× N + Σ(C
L
× V
CC
2
× f
o
) where:
f
i
= input frequency in MHz;
f
o
= output frequency in MHz;
C
L
= output load capacitance in pF;
V
CC
= supply voltage in V;
N = number of inputs switching;
Σ(C
L
× V
CC
2
× f
o
) = sum of the outputs.
Nexperia
74AUP1G3208
Low-power 3-input OR-AND gate
74AUP1G3208 All information provided in this document is subject to legal disclaimers. © Nexperia B.V. 2017. All rights reserved.
Product data sheet Rev. 7 — 7 March 2017
11 / 22
11.1 Waveforms and test circuit
Measurement points are given in Table 10.
V
OL
and V
OH
are typical output voltage levels that occur with the output load.
Figure 10. Input A, B and C to output Y propagation delay times
Table 10. Measurement points
Supply voltage Output Input
V
CC
V
M
V
M
V
I
t
r
= t
f
0.8 V to 3.6 V 0.5 × V
CC
0.5 × V
CC
V
CC
≤ 3.0 ns
Nexperia
74AUP1G3208
Low-power 3-input OR-AND gate
74AUP1G3208 All information provided in this document is subject to legal disclaimers. © Nexperia B.V. 2017. All rights reserved.
Product data sheet Rev. 7 — 7 March 2017
12 / 22
001aac521
DUT
R
T
V
I
V
O
V
EXT
V
CC
R
L
5 kΩ
C
L
G
Test data is given in Table 11.
Definitions for test circuit:
R
L
= Load resistance.
C
L
= Load capacitance including jig and probe capacitance.
R
T
= Termination resistance should be equal to the output impedance Z
O
of the pulse generator.
V
EXT
= External voltage for measuring switching times.
Figure 11. Test circuit for measuring switching times
Table 11. Test data
Supply voltage Load V
EXT
V
CC
C
L
R
L
[1]
t
PLH
, t
PHL
t
PZH
, t
PHZ
t
PZL
, t
PLZ
0.8 V to 3.6 V 5 pF, 10 pF, 15 pF and 30 pF 5 kΩ or 1 MΩ open GND 2 × V
CC
[1] For measuring enable and disable times R
L
= 5 kΩ.
For measuring propagation delays, setup and hold times and pulse width R
L
= 1 MΩ.

74AUP1G3208GM,132

Mfr. #:
Manufacturer:
Nexperia
Description:
Logic Gates 1.8V 1G LO-PWR
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union