TSL12S, TSL13S, TSL14S
LIGHT-TO-VOLTAGE CONVERTERS
TAOS051E − SEPTEMBER 2007
2
r
r
Copyright E 2007, TAOS Inc.
The LUMENOLOGY r Company
www.taosinc.com
Available Options
DEVICE T
A
PACKAGE − LEADS PACKAGE DESIGNATOR ORDERING NUMBER
TSL12S 0°C to 70°C 3-lead Sidelooker S TSL12S
TSL12S 0°C to 70°C 3-lead Sidelooker — Lead (Pb) Free S TSL12S−LF
TSL12S 0°C to 70°C 3-lead Surface-Mount Sidelooker — Lead (Pb) Free SM TSL12SM−LF
TSL13S 0°C to 70°C 3-lead Sidelooker S TSL13S
TSL13S 0°C to 70°C 3-lead Sidelooker — Lead (Pb) Free S TSL13S−LF
TSL13S 0°C to 70°C 3-lead Surface-Mount Sidelooker — Lead (Pb) Free SM TSL13SM−LF
TSL14S 0°C to 70°C 3-lead Sidelooker S TSL14S
TSL14S 0°C to 70°C 3-lead Sidelooker — Lead (Pb) Free S TSL14S−LF
TSL14S 0°C to 70°C 3-lead Surface-Mount Sidelooker — Lead (Pb) Free SM TSL14SM−LF
Terminal Functions
TERMINAL
NAME
NO.
TYPE DESCRIPTION
GND 1 Power supply ground (substrate). All voltages are referenced to GND.
OUT 3 O Output voltage.
V
DD
2 Supply voltage.
Absolute Maximum Ratings over operating free-air temperature range (unless otherwise noted)
†
Supply voltage, V
DD
(see Note 1) 6 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output current, I
O
±10 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Duration of short-circuit current at (or below) 25°C (see Note 2) 5 s. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
−25°C to 85°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
−25°C to 85°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds (S Package) 260°C. . . . . . . . . . . . . . . . . . . .
Reflow solder, in accordance with J-STD-020C or J-STD-020D (SM Package) 260°C. . . . . . . . . . . . . . . . . . .
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltages are with respect to GND.
2. Output may be shorted to supply.
Recommended Operating Conditions
MIN NOM MAX UNIT
Supply voltage, V
DD
2.7 5.5 V
Operating free-air temperature, T
A
0 70 °C