1415595

https://www.phoenixcontact.com/pi/products/1415595
08/17/2018Page4/7
Network cable-NBC-MSX/ 2,0-94S/MSX SCO RAIL-1415595
Technical data
Cable
74 dB (at 1000 MHz)
72 dB (at 1100 MHz)
70 dB (at 1200 MHz)
Power-summated near end crosstalk attenuation (PSNEXT) 97 dB (with 1 MHz)
96 dB (at 10 MHz)
92 dB (at 100 MHz)
89 dB (at 200 MHz)
87 dB (at 250 MHz)
80 dB (at 500 MHz)
78 dB (at 600 MHz)
77 dB (at 700 MHz)
74 dB (at 800 MHz)
72 dB (at 900 MHz)
71 dB (at 1000 MHz)
69 dB (at 1100 MHz)
67 dB (at 1200 MHz)
Attenuation 0.25 dB (with 1 MHz)
0.76 dB (at 10 MHz)
2.49 dB (at 100 MHz)
3.69 dB (at 200 MHz)
4.18 dB (at 250 MHz)
5.6 dB (at 500 MHz)
6.74 dB (at 600 MHz)
7.32 dB (at 700 MHz)
7.89 dB (at 800 MHz)
8.5 dB (at 900 MHz)
9.11 dB (at 1000 MHz)
9.5 dB (at 1100 MHz)
9.9 dB (at 1200 MHz)
Return loss (RL) 24 dB (with 1 MHz)
33.9 dB (at 10 MHz)
38.3 dB (at 100 MHz)
35.3 dB (at 200 MHz)
32.9 dB (at 250 MHz)
29.7 dB (at 500 MHz)
30.6 dB (at 600 MHz)
31 dB (at 700 MHz)
26.7 dB (at 800 MHz)
28.6 dB (at 900 MHz)
27.5 dB (at 1000 MHz)
https://www.phoenixcontact.com/pi/products/1415595
08/17/2018Page5/7
Network cable-NBC-MSX/ 2,0-94S/MSX SCO RAIL-1415595
Technical data
Cable
26.9 dB (at 1100 MHz)
26.3 dB (at 1200 MHz)
Crosstalk attenuation (ACR) 100 dB (with 1 MHz)
99 dB (at 10 MHz)
93 dB (at 100 MHz)
88 dB (at 200 MHz)
86 dB (at 250 MHz)
78 dB (at 500 MHz)
74 dB (at 600 MHz)
72 dB (at 700 MHz)
69 dB (at 800 MHz)
67 dB (at 900 MHz)
65 dB (at 1000 MHz)
63 dB (at 1100 MHz)
61 dB (at 1200 MHz)
Power-summated crosstalk attenuation (PS-ACR) 97 dB (with 1 MHz)
96 dB (at 10 MHz)
90 dB (at 100 MHz)
85 dB (at 200 MHz)
83 dB (at 250 MHz)
75 dB (at 500 MHz)
71 dB (at 600 MHz)
69 dB (at 700 MHz)
66 dB (at 800 MHz)
64 dB (at 900 MHz)
62 dB (at 1000 MHz)
60 dB (at 1100 MHz)
58 dB (at 1200 MHz)
Signal speed 0.78 c
Signal runtime 4.4 ns/m
Shield attenuation 60 dB (up to 1000 MHz)
Interference suppression 90 dB (up to 1000 MHz)
Coupling resistance 5.00 mΩ/m (at 10 MHz)
Nominal voltage, cable 125 V AC (Uo)
Test voltage Core/Core 1000 V AC (50 Hz, 1 min.)
Test voltage Core/Shield 1000 V AC (50 Hz, 1 min.)
Fire protection in rail vehicles BS 6853 (Internal cable Ia, Ib, II/external cable Ia, Ib, II)
DIN 5510-2 (Fire protection level 1, 2, 3, 4)
EN 45545-2
EN 50306-4
https://www.phoenixcontact.com/pi/products/1415595
08/17/2018Page6/7
Network cable-NBC-MSX/ 2,0-94S/MSX SCO RAIL-1415595
Technical data
Cable
NF F16-101 (Classification C/F1)
NF F16-101 (Internal cable A1, A2, B/external cable A1, A2, B)
NFPA 130
PN-K-02511 (Class A)
UIC 564-2 (Class A)
Flame resistance according to EN 60332-1-2
EN 60332-3-25
according to ISO 14572 5.21 (UN ECE-R 118.01)
Halogen-free According to EN 50267-2-1
according to EN 60684-2
Resistance to oil according to EN 60684-2, 72 h at 100 °C, IRM 902
Other resistance Resistant to fuel according to EN 60684-2, 72 h at 100 °C, IRM 903
Resistant to ozone according to EN 50306-4, 72 h at 40 °C, procedure
B, volume concentration 200 x 10
-6
Concentration of fumes EN 61034-2
Ambient temperature (operation) -40 °C ... 80 °C (cable, fixed installation)
Environmental Product Compliance
REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”,
Category “Manufacturer's declaration”
Drawings
Schematic diagram
18
27
36
45
Pin assignment of M12 plug, 8-pos., X-coded, pin side view
Cable cross section
Ethernet for rail applications[94S]

1415595

Mfr. #:
Manufacturer:
Phoenix Contact
Description:
Specialized Cables NBC-MSX/ 2 0-94S/ MSX SCO RAIL
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union