RSP-1500-24

1500W Single Output Power Supply
RSP-1500 series
5.Current Sharing with Remote Sense
RSP-1500 has the built-in active current sharing function and can be connected in parallel, up to 4 units, to provide higher output power as exhibited below :
Difference of output voltages among parallel units should be less than 0.2V.
The power supplies should be paralleled using short and large diameter wiring and then connected to the load.
Sense lines should be twisted in pairs to minimize noise pick-up.
When remote sensing is used in parallel operation, the sensing wire must be
connected only to the master unit
+V
+V
+V
+V
-V
-V
-V
-V
AC/L
AC/L
AC/L
AC/L
AC/N
AC/N
AC/N
AC/N
No.1(Master)
No.2(Slave)
No.3(Slave)
No.4(Slave)
Load
+V
-V
+S
-S
+S,-S and CS are connected mutually in paralle.
The total output current must not exceed the value determined by the following equation:
Maximum output current at parallel operation=(Rated current per unit) (Number of unit) 0.9××
File Name:RSP-1500-SPEC 2018-01-15
File Name:RSP-1500-SPEC 2018-01-15
1500W Single Output Power Supply
RSP-1500 series
CN1 CN2 CN3
Mechanical Specification
Case No.943A Unit:mm
direction
93
Air flow
16
I/P
3
2
-V
1
+V
17.5
1013
240
11.2
16 max.
278
8-M4 L=5(Both Sides)
83.5
38
38.1
22.7
4-M4 L=5
127
11.2
240
LED
SVR
OUTPUT
77555333111
22442
664886
4
82
17
Mounting Instruction
Hole No. Recommended Screw Size MAX. Penetration Depth L Recommended mounting torque
1
5mm
M4
Control Pin No.Assignment : HRS DF11-8DP-2DS or equivalent(CN1,CN2)
CN1 and CN2 are connected internally.
Mating Housing
Terminal
HRS DF11-8DS or equivalent
HRS DF11-**SC or equivalent
7~1 Kgf-cm0
Pin No.
1
2
Function
RCG
RC2
Description
Remote ON-OFF Ground
Remote ON-OFF
4
3,5,7
6
8
TRIM
-S
LS(Current Share)
+S
Connection for output voltage programming
Negative sensing for remote sense
Current Share
Postive sensing for remote sense
1 1
1 1
1 1
Mounting Screw
Mounting Surface
Chassis of RSP-1500
L
2-M4
ψ8.5
File Name:RSP-1500-SPEC 2018-01-15
1500W Single Output Power Supply
RSP-1500 series
4
5
AUXG
RCG
AUX
Auxiliary Ground
Remote ON-OFF Ground
Auxiliary Output
6
RC1
Remote ON-OFF
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
AC Input Terminal Pin No. Assignment
Pin No.
1
3
2
Assignment Diagram Mxa imum mounting torque
18Kgf-cm
AC/L
AC/N
2
1
6
5
Control Pin No.Assignment : HRS DF11-6DP-2DS or equivalent(CN3)
Mating Housing
Terminal
HRS DF11-6DS or equivalent
HRS DF11-**SC or equivalent
Pin No.
1
2
Function
P OK GND
POK
Description
Power OK Ground
Power OK Signal
3
FG

RSP-1500-24

Mfr. #:
Manufacturer:
MEAN WELL
Description:
Switching Power Supplies 1512W 24V 63A
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: