VCP15US24

Specification
15 Watts
Low Cost
Output Voltages from 5 to 24 V
PCB Mounting
Open Frame & Encapsulated Versions
IT & Medical Approvals
Class II Construction
No Load Input Power <0.3 W
VCP Series
Input
Input Voltage 90-264 VAC
Input Frequency 47-63 Hz
Input Current 0.5 A max at 90 VAC
Inrush Current 40 A max at 240 VAC, cold start at 25 °C
Power Factor EN61000-3-2, class A
No Load Input Power <0.3 W
Input Protection Internal T2.0A/250 V fuse in line
Output
Output Voltage See table
Initial Set Accuracy ±2% at 50% load
Minimum Load No minimum load required
Start Up Delay 2 s max
Start Up Rise Time 100 ms typical
Hold Up Time 5 ms typical at full load and 115 VAC
Line Regulation ±0.5% max
Load Regulation 2% max, 0-100% load
Transient Response 10% max. deviation, recovery to <1%
within 500 µs for a 50% step load change
at 0.2 A/µs
Ripple & Noise See table
Overvoltage Protection See table
Overload Protection 120-280 %, auto recovery
Short Circuit Protection Trip and restart (hiccup mode)
Temperature 0.2 %/°C
Coefficient
xppower.com
General
Efficiency See table
Isolation 4000 VAC Input to Output
Switching Frequency 132 kHz typical
MTBF 250 kHrs to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature 0 °C to +70 °C, derate from 100% load at
50 °C to 50% load at 70 °C
Cooling Natural convection
Operating Humidity 5-90% RH, non-condensing
Storage Temperature -20 °C to +80 °C
Vibration 10-300 Hz, 2 g 15 mins/sweep. 30 mins
for each of 3 axes
EMC & Safety
Emissions EN55011/22, level B conducted & radiated
Harmonic Currents EN61000-3-2, class A
Voltage Flicker EN61000-3-3
ESD Immunity EN61000-4-2, ±4 kV indirect contact,
±8 kV air, Perf Criteria A
Radiated Immunity EN61000-4-3, 3 V/m, Perf Criteria A
EFT/Burst EN61000-4-4, level 2, Perf Criteria A
Surge EN61000-4-5 installation class 3,
Perf Criteria A
Conducted Immunity EN61000-4-6, 3 V, Perf Criteria A
Magnetic Field EN61000-4-8, 1 A/m, Perf Criteria A
Dips & Interruptions EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B
Safety Approvals EN60950-1, cUL60950-1, IEC60950-1,
EN60601-1, cUL60601-1, IEC60601-1
ACDC
B R A N D
VCP15
04-Oct-11
ACDC
Output Power Output Voltage
(2)
Output Current Ripple & Noise
(1)
OVP Setting
(3)
Efficiency
(5)
Model Number
(4)
10 W 5.0 V 2.00 A 100 mV 10.0 V 74% VCP15US05
15 W 12.0 V 1.25 A 100 mV 20.0 V 82% VCP15US12
15 W 15.0 V 0.90 A 150 mV 25.0 V 83% VCP15US15
15 W 24.0 V 0.63 A 200 mV 35.0 V 84% VCP15US24
1. Measured at DC output connector using 20 MHz bandwidth and 0.1 µF ceramic capacitor in parallel with 10 µF electrolytic capacitor placed at connector terminals.
2. Other voltages between 5.0 V and 24 V are available, consult sales for details.
3. Typical trip point.
4. For encapsulated versions, add suffix ‘-E’ to the model number e.g VCP15US24-E.
5. Average of efficiencies measured at 25%, 50%, 75% & 100% load and 230 VAC input.
Models and Ratings
Mechanical Details
Notes
1. All dimensions are in inches (mm).
2. Weight: Open frame versions: 0.09 lbs (40 g) approx.
Encapsulated versions: 0.22 lbs (100 g) approx.
3. Tolerance: x.xx = ±0.04 (x.x = ±0.1); x.xxx = ±0.2 (x.xx = ±0.5)
Pin Designation
1 Live
2 Neutral
3 No connection
4 Output -VE
5 Output +VE
Notes
0.06
(1.60)
0.15
(3.80)
0.18
(4.50)
ø 0.070
(ø1.80)
ø 0.04
(ø1.00)
0.85
(21.50)
1.24
(31.40)
1.49 (38)
0.555
(14.1)
0.484 (12.3)
1.27 (32.5)
2.55 (65.0)
1.209 (30.7)
0.819 (20.8)
0.465
(11.8)
0.67
(17.0)
1.205 (30.6)
0.626
(15.9)
0.677
(17.2)
1
2
3
4
5
1.197 (30.4)
TOP VIEW
0.626 (15.9)
1.65 (42.0)
0.465 (11.8) 0.677 (17.2)
0.484 (12.3)
1.209 (30.7)
1.205 (30.6)
0.819 (20.8)
3
2
1
4
5
0.555 (14.1)
1.11 (28.2)
0.15 (3.80)
0.67 (17.0)
1.197 (30.4)
2.72 (69.0)
TOP VIEW
ø 0.04
(ø1.00)
Encapsulated Version (E)Open Frame Version

VCP15US24

Mfr. #:
Manufacturer:
Description:
AC/DC CONVERTER 24V 15W
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet